Abdul Hadi Abdul Wahab

Abdul Hadi Abdul Wahab

Auto-generated profile, based on publicly available information

Abdul Hadi Abdul Wahab

Center for Multimodal Signal Processing, Faculty of Engineering and Technology, Tunku Abdul Rahman University College, Setapak, 53300, Federal Territory of Kuala Lumpur, Malaysia

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2019 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
AWAbdul Hadi Abdul Wahab
Abdul Hadi Abdul Wahab
ASAmir Putra Md Saad
Amir Putra Md Saad
MHMuhammad Noor Harun
Muhammad Noor Harun
ASArdiyansyah Syahrom
Ardiyansyah Syahrom
Muhammad Hanif RamleeMuhammad Hanif Ramlee
Muhammad Hanif Ramlee
MKMohammed Rafiq Abdul Kadir
Mohammed Rafiq Abdul Kadir

20 September 2016 in Soft Materials
Verified
Journal Article
Closed access
SASyuhada Azmi
Syuhada Azmi
Saiful Izwan Abd RazakSaiful Izwan Abd Razak
Saiful Izwan Abd Razak
MKMohammed Rafiq Abdul Kadir
Mohammed Rafiq Abdul Kadir
NINida Iqbal
Nida Iqbal
RHRozita Hassan
Rozita Hassan
SSShahrulzaman Shaharuddin
Shahrulzaman Shaharuddin
This work reports the reinforcement of poly(vinyl alcohol) (PVA) hydrogel with halloysite nanotubes (HNT) as potential biomedical materials. The nanocomposite hydrogel was prepared using the facile and harmless process of freeze–thawing. Mechanical properties of the hydrogels were optimum at 2 wt% of HNT loading. Morphological and topographic analysis of the PVA/HNT hydrogel revealed excellent filler dispersion and smoothing of surface due to good compatibility between the components. Immersion of the PVA/HNT hydrogel in simulated body fluid for 7 days resulted in the formation of fully covered apatite layers on the surface. This is a good indication of bioactivity for artificial cartilage material.


15 August 2021 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
NANur Afikah Zainal Abidin
Nur Afikah Zainal Abidin
AWAbdul Hadi Abdul Wahab
Abdul Hadi Abdul Wahab
RRRabiatul Adibah Abdul Rahim
Rabiatul Adibah Abdul Rahim
MKMohammed Rafiq Abdul Kadir
Mohammed Rafiq Abdul Kadir
Muhammad Hanif RamleeMuhammad Hanif Ramlee
Muhammad Hanif Ramlee

2 June 2016 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
AWAbdul Hadi Abdul Wahab
Abdul Hadi Abdul Wahab
MKMohammed Rafiq Abdul Kadir
Mohammed Rafiq Abdul Kadir
MHMuhammad Noor Harun
Muhammad Noor Harun
TKTunku Kamarul
Tunku Kamarul
ASArdiyansyah Syahrom
Ardiyansyah Syahrom

17 April 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
BNBing Wui Ng
Bing Wui Ng
AWAbdul Hadi Abdul Wahab
Abdul Hadi Abdul Wahab
AWAbdul Muttalib Abdul Wahid
Abdul Muttalib Abdul Wahid
NIK NUR AIN AZRIN ABDULLAHNIK NUR AIN AZRIN ABDULLAH
NIK NUR AIN AZRIN ABDULLAH
MKMohammed Rafiq Abdul Kadir
Mohammed Rafiq Abdul Kadir
Muhammad Hanif RamleeMuhammad Hanif Ramlee
Muhammad Hanif Ramlee
External fixators have been used effectively in damage control orthopaedic and open fractures management of various bones. It is well known that stability of external fixators is greatly influenced by its construct. Various rules have been documented to influence the stiffness and stability of external fixators. In this study, two clinical cases treated with a novel concept of cross self-locking rods external fixation construct were being described, coupled with biomechanical analysis of its stability in comparison with other constructs by using finite element study. These novel self-locking rods configuration proven improve strength by applying the same numbers of rod and pin with the delta frame construct in clinical practice. A validated three-dimensional (3D) model of the bone from a previous study was used and external fixator were designed via computer-aided design (CAD) modelling software, Solidworks. A 1500 N load representing the axial load compression during weight bearing was applied to the tibia with the distal segment of the fracture site secured without any movement. The clinical results showed bone healing process with both cases achieving bone union within the acceptable time. The results of the finite element study shows that the double cross self-locking rods construct had better stability since it showed optimum magnitude in relative micromotion (0.18 mm), lowest stress at the fracture site (189 MPa), displacement of fixator (13.4 mm), and stress at the fixator (687 MPa). In conclusion, double cross self-locking design could provide optimum stability of the external fixator construct by providing better stress distribution at the bone and external fixator, minimize displacement and micromotion at fracture fragments.