An effective approach to increasing energy efficiency in buildings without compromising thermal comfort is to optimize heating, ventilation, and air conditioning (HVAC) systems through the use of advanced building-management system features, such as fault detection and diagnosis. Such functions are usually developed based on simulation models that must be calibrated and validated to achieve an appropriate level of accuracy and reliability. The objective of this study was to develop and calibrate a room-level simulation model of a hotel building and its HVAC system using TRNSYS 18 software and real data collected from the smart room system installed in the building. The calibration process was performed with 100 rooms using 5-min samples of room temperatures in selected 1-month periods during the summer and winter seasons by minimizing the root mean squared error (RMSE) in the average of the observed rooms using a genetic algorithm. The calibrated model was able to predict room temperatures with an RMSE of 0.79 ± 0.14 °C and a coefficient of variation in the root mean squared error (cvRMSE) of 3.58 ± 0.7%, which is well below the limits prescribed by international guidelines. The model was then applied to detect faults in the operation of fan coil units in the rooms based on the residual analysis and defined if–then rules. The results obtained show that the model can track the trends of temperature changes in real conditions and successfully detect major anomalies in a system.
In order to reduce global energy consumption, energy-efficient, green and smart buildings have to be built. In addition to the application of other energy efficiency measures, an effective management of HVAC systems is required. High quality management and control of these systems ensures optimal occupant comfort levels, proper operation, rational energy consumption, and a positive impact on the environment. This is especially important for large buildings with complex systems such as hotels. As a contribution to the creation of appropriate tools for the management and control of HVAC systems in smart buildings, this paper presents the results of the current development of a detailed dynamic simulation model based on data collected from a smart room system in a hotel in Zagreb, Croatia. The smart room system, which is integrated into the hotel's building management system, provides historical data on set and current room temperatures, room occupancy schedule, window opening, fan coil operation status, fan rotation speed, valve opening, and operating mode with a time step of 5 minutes. The simulation model based on the TRNSYS software uses a part of the available data and calculates the current internal room temperatures. A comparison of the predicted and measured temperatures at each time step showed that the deviations are within the acceptable limits. The final objectives of the model development are the identification of anomalies in the operation of the HVAC system and the optimization of its operation with the aim of reducing energy consumption.