Sandi Ljubic

Prof. Dr. Sandi Ljubic

Department of Computer Engineering, University of Rijeka, Faculty of Engineering, Rijeka, Primorsko-Goranska Županija, Croatia
+1
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
IMIva Matetić
Iva Matetić
Ivan ŠtajduharIvan Štajduhar
Ivan Štajduhar
IWIgor Wolf
Igor Wolf
Sandi LjubicSandi Ljubic
Sandi Ljubic
Heating, ventilation, and air conditioning (HVAC) systems are a popular research topic because buildings’ energy is mostly used for heating and/or cooling. These systems heavily rely on sensory measurements and typically make an integral part of the smart building concept. As such, they require the implementation of fault detection and diagnosis (FDD) methodologies, which should assist users in maintaining comfort while consuming minimal energy. Despite the fact that FDD approaches are a well-researched subject, not just for improving the operation of HVAC systems but also for a wider range of systems in industrial processes, there is a lack of application in commercial buildings due to their complexity and low transferability. The aim of this review paper is to present and systematize cutting-edge FDD methodologies, encompassing approaches and special techniques that can be applied in HVAC systems, as well as to provide best-practice heuristics for researchers and solution developers in this domain. While the literature analysis targets the FDD perspective, the main focus is put on the data-driven approach, which covers commonly used models and data pre-processing techniques in the field. Data-driven techniques and FDD solutions based on them, which are most commonly used in recent HVAC research, form the backbone of our study, while alternative FDD approaches are also presented and classified to properly contextualize and round out the review.

4 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
DADamir Arbula
Damir Arbula
Sandi LjubicSandi Ljubic
Sandi Ljubic
Accurate, inexpensive, and reliable real-time indoor localization holds the key to the full potential of the context-aware applications and location-based Internet of Things (IoT) services. State-of-the-art indoor localization systems are coping with the complex non-line-of-sight (NLOS) signal propagation which hinders the use of proven multiangulation and multilateration methods, as well as with prohibitive installation costs, computational demands, and energy requirements. In this paper, we present a novel sensor utilizing low-range infrared (IR) signal in the line-of-sight (LOS) context providing high precision angle-of-arrival (AoA) estimation. The proposed sensor is used in the pragmatic solution to the localization problem that avoids NLOS propagation issues by exploiting the powerful concept of the wireless sensor network (WSN). To demonstrate the proposed solution, we applied it in the challenging context of the supermarket cart navigation. In this specific use case, a proof-of-concept navigation system was implemented with the following components: IR-AoA sensor prototype and the corresponding WSN used for cart localization, server-side application programming interface (API), and client application suite consisting of smartphone and smartwatch applications. The localization performance of the proposed solution was assessed in, altogether, four evaluation procedures, including both empirical and simulation settings. The evaluation outcomes are ranging from centimeter-level accuracy achieved in static-1D context up to 1 m mean localization error obtained for a mobile cart moving at 140 cm/s in a 2D setup. These results show that, for the supermarket context, appropriate localization accuracy can be achieved, along with the real-time navigation support, using readily available IR technology with inexpensive hardware components.

8 December 2013 in Universal Access in the Information Society
Verified
Journal Article
Closed access
PDF file
LKLuka Krapic
Luka Krapic
Kristijan LenacKristijan Lenac
Kristijan Lenac
Sandi LjubicSandi Ljubic
Sandi Ljubic

7 January 2024 in Computer Applications in Engineering Education
Verified
Journal Article
Open access
RSRoberto Sala
Roberto Sala
AMAntonio Maffei
Antonio Maffei
FPFabiana Pirola
Fabiana Pirola
FEFredrik Enoksson
Fredrik Enoksson
Sandi LjubicSandi Ljubic
Sandi Ljubic
GPGiuditta Pezzotta
Giuditta Pezzotta
Blended Learning (BL) is defined as a combination of face‐to‐face and digital activities that, in recent years, has been adopted more and more frequently by Higher Educational Institutions (HEIs). In the engineering field, the adoption of BL allows creating challenging situations for students with industry‐like problems to foster the acquisition of advanced problem‐solving skills. Thus, it can be used to enhance traditional learning by enriching it with new aspects, allowing to update the Intended Learning Outcomes traditionally defined by teachers. Although prior coronavirus disease 2019 (COVID‐19) teachers had the time to prepare and programme the transition to BL, during the pandemic they had to abruptly move to the full digital delivery of the content, requiring technological and organizational adaptation, as well as change in the content teaching and assessment methods. Through a systematic literature review, this paper aims to understand how BL has been implemented in the engineering field by HEIs, discussing if and how the learning expectations of teachers (evaluated through Bloom's Taxonomy) change when using different mixes of face‐to‐face and digital activities and when the target audience changes. More specifically, the investigation addresses how content and learning expectations are split and set in face‐to‐face and digital settings. Additionally, the interest is towards understanding how COVID‐19 impacted the adoption of BL, not only during the pandemic but also after.

26 May 2023 in Buildings
Verified
Journal Article
Open access
PDF file
DPDarko Palaić
Darko Palaić
Ivan ŠtajduharIvan Štajduhar
Ivan Štajduhar
Sandi LjubicSandi Ljubic
Sandi Ljubic
IWIgor Wolf
Igor Wolf
An effective approach to increasing energy efficiency in buildings without compromising thermal comfort is to optimize heating, ventilation, and air conditioning (HVAC) systems through the use of advanced building-management system features, such as fault detection and diagnosis. Such functions are usually developed based on simulation models that must be calibrated and validated to achieve an appropriate level of accuracy and reliability. The objective of this study was to develop and calibrate a room-level simulation model of a hotel building and its HVAC system using TRNSYS 18 software and real data collected from the smart room system installed in the building. The calibration process was performed with 100 rooms using 5-min samples of room temperatures in selected 1-month periods during the summer and winter seasons by minimizing the root mean squared error (RMSE) in the average of the observed rooms using a genetic algorithm. The calibrated model was able to predict room temperatures with an RMSE of 0.79 ± 0.14 °C and a coefficient of variation in the root mean squared error (cvRMSE) of 3.58 ± 0.7%, which is well below the limits prescribed by international guidelines. The model was then applied to detect faults in the operation of fan coil units in the rooms based on the residual analysis and defined if–then rules. The results obtained show that the model can track the trends of temperature changes in real conditions and successfully detect major anomalies in a system.

1 December 2019 in Pattern Recognition Letters
Verified
Journal Article
Closed access
ASArian Skoki
Arian Skoki
Sandi LjubicSandi Ljubic
Sandi Ljubic
JLJonatan Lerga
Jonatan Lerga
Ivan ŠtajduharIvan Štajduhar
Ivan Štajduhar