Yuze Sun

Dr. Yuze Sun

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2017 in Sensors
Verified
Journal Article
Open access
PDF file
YLYonghao Liu
Yonghao Liu
WZWeidong Zhou
Weidong Zhou
YSYuze Sun
Yuze Sun
High sensitivity (S) and high quality factor (Q) are desirable to achieve low detection limit in label-free optical sensors. In this paper, we theoretically demonstrate that single-layer and coupled bi-layer photonic crystal slabs (PCS) possess simultaneously high S and high Q near the bound states in the continuum (BIC). We theoretically achieved S > 800 nm/RIU and Q > 107 in refractive index sensing in the 1400–1600 nm telecom optical wavelength bands. We experimentally demonstrated an S of 94 nm/RIU and a Q of 1.2 × 104, with a detection limit of 6 × 10−5 refractive index unit. These sensor designs can find applications in biochemical sensing, environmental monitoring, and healthcare.

27 April 2017 in Optics Express
Verified
Journal Article
Open access
PDF file
YLYonghao Liu
Yonghao Liu
SWShuling Wang
Shuling Wang
DZDeyin Zhao
Deyin Zhao
WZWeidong Zhou
Weidong Zhou
YSYuze Sun
Yuze Sun
We report here the refractive index (RI) sensing using the singly degenerate high quality factor (Q) modes in photonic crystal slabs (PCS) with the free-space coupled incident beam close to normal incidence. Q values of 3.2x104 and 1.8x104 were achieved for the fabricated PCS in air and aqueous solution, respectively. A spectral sensitivity (S) of 94.5 nm/RIU and a detection limit (DL) of 3x10−5 RIU were achieved with our device. Such a high-Q cavity for the singly degenerate mode close to normal incidence is very promising to achieve a lower DL for RI sensing.

4 November 2024 in The Lancet Public Health
Verified
Journal Article
Open access
Wenjia CaiWenjia Cai
Wenjia Cai
CZChi Zhang
Chi Zhang
SZShihui Zhang
Shihui Zhang
Yuqi BaiYuqi Bai
Yuqi Bai
MCMax Callaghan
Max Callaghan
Peng GongPeng Gong
Peng Gong

27 February 2017 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
SWShuling Wang
Shuling Wang
YLYonghao Liu
Yonghao Liu
DZDeyin Zhao
Deyin Zhao
HYHongjun Yang
Hongjun Yang
WZWeidong Zhou
Weidong Zhou
YSYuze Sun
Yuze Sun
We report an ultra-compact surface-normal optofluidic refractometric sensor based on a two-dimensional silicon photonic crystal on insulator. In contrast to the conventional symmetric Lorentzian resonance that is prevalently used in the label-free sensors, the asymmetric lineshape and steep peak-to-dip transition of a Fano resonance enable the enhanced detection sensitivity. The detection limit of 1.3 × 10−6 refractive index units is achieved, which is among the lowest reported experimentally in the defect-free photonic crystal sensors.

9 September 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
PBPriyanka Biswas
Priyanka Biswas
CZChen Zhang
Chen Zhang
YCYudong Chen
Yudong Chen
Zhonghe LiuZhonghe Liu
Zhonghe Liu
SVSeyedmohsen Vaziri
Seyedmohsen Vaziri
YSYuze Sun
Yuze Sun
The miniaturization of gas chromatography (GC) systems has made it possible to utilize the analytical technique in various on-site applications to rapidly analyze complex gas samples. Various types of miniaturized sensors have been developed for micro-gas chromatography (µGC). However, the integration of an appropriate detector in µGC systems still faces a significant challenge. We present a solution to the problem through integration of µGC with photonic crystal slab (PCS) sensors using transfer printing technology. This integration offers an opportunity to utilize the advantages of optical sensors, such as high sensitivity and rapid response time, and at the same time, compensate for the lack of detection specificity from which label-free optical sensors suffer. We transfer printed a 2D defect free PCS on a borofloat glass, bonded it to a silicon microfluidic gas cell or directly to a microfabricated GC column, and then coated it with a gas responsive polymer. Realtime spectral shift in Fano resonance of the PCS sensor was used to quantitatively detect analytes over a mass range of three orders. The integrated µGC–PCS system was used to demonstrate separation and detection of a complex mixture of 10 chemicals. Fast separation and detection (4 min) and a low detection limit (ng) was demonstrated.

21 May 2020 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
HZHan Zhang
Han Zhang
PPPrithviraj Palit
Prithviraj Palit
YLYonghao Liu
Yonghao Liu
SVSeyedmohsen Vaziri
Seyedmohsen Vaziri
YSYuze Sun
Yuze Sun