Zhonghe Liu

Dr. Zhonghe Liu

Southwest Institute of Technical Physics, Chengdu, Sichuan, China
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 July 2019 in Science Advances
Verified
Journal Article
Open access
PDF file
JSJiho Shin
Jiho Shin
Zhonghe LiuZhonghe Liu
Zhonghe Liu
Wubin BaiWubin Bai
Wubin Bai
YLYonghao Liu
Yonghao Liu
YYYing Yan
Ying Yan
John A. RogersJohn A. Rogers
John A. Rogers
Bioresorbable optical sensor implants monitor brain pressure and temperature before naturally resorbing into the body.

9 September 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
PBPriyanka Biswas
Priyanka Biswas
CZChen Zhang
Chen Zhang
YCYudong Chen
Yudong Chen
Zhonghe LiuZhonghe Liu
Zhonghe Liu
SVSeyedmohsen Vaziri
Seyedmohsen Vaziri
YSYuze Sun
Yuze Sun
The miniaturization of gas chromatography (GC) systems has made it possible to utilize the analytical technique in various on-site applications to rapidly analyze complex gas samples. Various types of miniaturized sensors have been developed for micro-gas chromatography (µGC). However, the integration of an appropriate detector in µGC systems still faces a significant challenge. We present a solution to the problem through integration of µGC with photonic crystal slab (PCS) sensors using transfer printing technology. This integration offers an opportunity to utilize the advantages of optical sensors, such as high sensitivity and rapid response time, and at the same time, compensate for the lack of detection specificity from which label-free optical sensors suffer. We transfer printed a 2D defect free PCS on a borofloat glass, bonded it to a silicon microfluidic gas cell or directly to a microfabricated GC column, and then coated it with a gas responsive polymer. Realtime spectral shift in Fano resonance of the PCS sensor was used to quantitatively detect analytes over a mass range of three orders. The integrated µGC–PCS system was used to demonstrate separation and detection of a complex mixture of 10 chemicals. Fast separation and detection (4 min) and a low detection limit (ng) was demonstrated.

23 November 2021 in Optics Express
Verified
Journal Article
Closed access
MPMingsen Pan
Mingsen Pan
Zhonghe LiuZhonghe Liu
Zhonghe Liu
AKAkhil Raj Kumar Kalapala
Akhil Raj Kumar Kalapala
YCYudong Chen
Yudong Chen
YSYuze Sun
Yuze Sun
WZWeidong Zhou
Weidong Zhou
Photonic crystal slabs are the state of the art in the studies of the light confinement, optical wave modulating and guiding, as well as nonlinear optical response. Previous studies have shown abundant real-world implementations of photonic crystals in planar optics, metamaterials, sensors, and lasers. Here, we report a novel full 2π phase control method in the reflected light beam over the interaction with a photonic crystal resonant mode, verified by the temporal coupled-mode analysis and S-parameter simulations. Enhanced by the asymmetric coupling with the output ports, the 2π phase shift can be achieved with the silicon photonics platforms such as Silicon-on-Silica and Silicon-on-Insulator heterostructures. Such photonic crystal phase control method provides a general guide in the design of phase-shift metamaterials, suggesting a wide range of applications in the field of sensing, spatial light modulation, and beam steering.

25 January 2021 in BME Frontiers
Verified
Journal Article
Open access
PDF file
Wubin BaiWubin Bai
Wubin Bai
MIMasahiro Irie
Masahiro Irie
Zhonghe LiuZhonghe Liu
Zhonghe Liu
HLHaiwen Luan
Haiwen Luan
DFDaniel Franklin
Daniel Franklin
John A. RogersJohn A. Rogers
John A. Rogers
Objective and Impact Statement . Real-time monitoring of the temperatures of regional tissue microenvironments can serve as the diagnostic basis for treating various health conditions and diseases. Introduction . Traditional thermal sensors allow measurements at surfaces or at near-surface regions of the skin or of certain body cavities. Evaluations at depth require implanted devices connected to external readout electronics via physical interfaces that lead to risks for infection and movement constraints for the patient. Also, surgical extraction procedures after a period of need can introduce additional risks and costs. Methods . Here, we report a wireless, bioresorbable class of temperature sensor that exploits multilayer photonic cavities, for continuous optical measurements of regional, deep-tissue microenvironments over a timeframe of interest followed by complete clearance via natural body processes. Results . The designs decouple the influence of detection angle from temperature on the reflection spectra, to enable high accuracy in sensing, as supported by in vitro experiments and optical simulations. Studies with devices implanted into subcutaneous tissues of both awake, freely moving and asleep animal models illustrate the applicability of this technology for in vivo measurements. Conclusion . The results demonstrate the use of bioresorbable materials in advanced photonic structures with unique capabilities in tracking of thermal signatures of tissue microenvironments, with potential relevance to human healthcare.

14 December 2022 in Optics Express
Verified
Journal Article
Closed access
MPMingsen Pan
Mingsen Pan
ALAaron Liu
Aaron Liu
Zhonghe LiuZhonghe Liu
Zhonghe Liu
WZWeidong Zhou
Weidong Zhou
Reconfigurable metasurfaces have been pursued intensively in recent years for the ability to modulate the light after fabrication. However, the optical performances of these devices are limited by the efficiency, actuation response speed and mechanical control for reconfigurability. In this paper, we propose a fast tunable optical absorber based on the critical coupling of resonance mode to absorptive medium and the plasma dispersion effect of free carriers in semiconductor. The tunable absorber structure includes a single-layer or bi-layer silicon photonic crystal slab (PCS) to induce a high-Q optical resonance, a monolayer graphene as the absorption material, and bottom reflector to remove transmission. By modulating the refractive index of PCS via the plasma dispersion of the free carrier, the critical coupling condition is shifted in spectrum, and the device acquires tuning capability between perfect absorption and total reflection of the incident monochromatic light beam. Simulation results show that, with silicon index change of 0.015, the tunable absorption of light can achieve the reflection/absorption switching, and full range of reflection phase control is feasible in the over coupling region. The proposed reconfigurable structure has potential applications in remote sensing, free-space communications, LiDAR, and imaging.

29 September 2021 in Nanophotonics
Verified
Journal Article
Open access
PDF file
Zhonghe LiuZhonghe Liu
Zhonghe Liu
YCYudong Chen
Yudong Chen
XGXiaochen Ge
Xiaochen Ge
WZWeidong Zhou
Weidong Zhou
We present the design, fabrication, and characterization of suspended arrays of small volume, high quality factor ( Q ) silicon nitride photonic crystal nanobeam (PCNB) cavities with lateral nanorod fin structures. By controlling the alignment position of the fins with respect to the air holes, the resonance wavelength and Q ‐factor of the PCNB cavities can be tuned to realize the desired performance. Measured tunable range of 2 × 10 4 and 10 nm is achieved for Q ‐factor and resonance wavelength, respectively, with the highest Q ‐factor measured at 2.5 × 10 4 . Incorporating such nanorod fins into the nanobeam cavity is demonstrated to provide improved mechanical support, thermal transport, and channels of lateral carrier injection for the suspended PCNB. The proposed PCNB cavities with lateral fins are advantageous for energy efficient, ultra‐compact lasers, modulators, filters, and sensors.