Attila Mészáros

Mr. Attila Mészáros

Faculty of Engineering, University of Szeged, Szeged, Csongrád, Hungary
orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 May 2023 in Actuators
Verified
Journal Article
Open access
PDF file
Attila MészárosAttila Mészáros
Attila Mészáros
Jozsef SarosiJozsef Sarosi
Jozsef Sarosi
The application of soft actuators has become increasingly common in wearable devices. In this study, we investigated the force characteristics of soft actuators made entirely of elastic material, when equipped with solid external chamber plates of varying thickness that can be attached from the outside. This study examines the effect of these plates on the force characteristics of a fully silicone-based fifteen-chamber soft actuator without any non-stretchable internal components. The parameters of the actuator were determined with consideration of wearable applications, such as rehabilitation devices and exoskeletons. The observed differences in the behavior of the actuator at various pressure levels and plate thicknesses were measured. Furthermore, the effect of the externally inserted plates between the chambers on the passive bending of the actuator was examined. The obtained results were evaluated and compared to determine how external chamber plates of given thicknesses affect the operational performance of a soft actuator.

30 January 2026 in Actuators
Verified
Journal Article
Open access
PDF file
SCSándor Csikós
Sándor Csikós
Attila MészárosAttila Mészáros
Attila Mészáros
Jozsef SarosiJozsef Sarosi
Jozsef Sarosi
This paper introduces a compact pneumatic artificial muscle (CPAM) that integrates a coaxial rod and an internal helical compression spring (stiffness 9750 N/m) into a McKibben-type outer muscle and compares it to a commercial DMSP-20-200N from FESTO Budapest, Hungary, with identical outer geometry and materials. Both actuators were mounted in a force-controlled test rig, pre-tensioned, and then cycled quasi-statically between their stretched and maximally contracted states at 13 internal pressures. For each pressure, median loading and unloading force–contraction curves were obtained from five repeats measuring both the cylinder excitation force and a load cell, and hysteresis was quantified by a normalized loop area based on peak force and common contraction range. Under the rated load of 2000 N at 0.6 MPa, the CPAM elongates less (−1.5% vs. −3%) and generates higher forces over most of the contraction range. The normalized hysteresis index of the CPAM is markedly lower at low pressures (≈0.05–0.25 MPa, reductions of about 10–25%), similar near 0.30 MPa, and slightly higher at 0.35–0.60 MPa (≈6–14%).

7 September 2026 in Actuators
Verified
Journal Article
Open access
PDF file
Attila MészárosAttila Mészáros
Attila Mészáros
Jozsef SarosiJozsef Sarosi
Jozsef Sarosi
Soft and compliant rehabilitation devices may provide improved anatomical adaptability, reduced distal mass, and more flexible human–robot interaction compared with conventional rigid exoskeletons. This scoping review examines elbow rehabilitation technologies across three interconnected domains: (1) the broader landscape of soft and compliant actuation, (2) the structural, material, and operating architectures of pneumatic soft actuators, and (3) the sensing, intention-detection, and closed-loop control methods used in pneumatic systems. The review included 109 peer-reviewed reports. Four main actuation families were identified: pneumatic soft actuators, motor-driven cable and tendon systems, series-elastic or variable-stiffness actuators, and shape-memory-alloy-based devices. Pneumatic architectures were primarily organized around linear artificial muscles and chamber-based bending or rotary actuators, complemented by rigid–soft integrated, cable-transmitted, modular, antagonistic, self-sensing, and variable-stiffness configurations. Feedback most relied on pressure, kinematic, force, and electromyographic signals. Control architectures combined position, force, torque, impedance, and pressure regulation, while nonlinearities and uncertainties were addressed using model-based, adaptive, sliding-mode, fuzzy, neural, and hybrid methods.

1 January 1995
Verified
Book Chapter
Closed access
Attila MészárosAttila Mészáros
Attila Mészáros
JMJ. Mekleš
J. Mekleš
PLP. Lednický
P. Lednický

4 August 2024 in Analecta Technica Szegedinensia
Verified
Journal Article
Open access
PDF file
Attila MészárosAttila Mészáros
Attila Mészáros
RMRéka Mátó
Réka Mátó
Jozsef SarosiJozsef Sarosi
Jozsef Sarosi
In recent years, there has been a growing demand for wearable actuators, that can be worn on individual body parts. This demand is dynamically increasing due to the numerous potential applications such as rehabilitation and enhancing load-bearing capabilities. Exoskeletons are mechanical structures that supplement or facilitate human movements and increase the body parts natural capabilities. Despite their wide range of applications, rigid exoskeletons have several deficiencies that required further developments. Soft actuators have been developed to address these deficiencies, forming one of the main categories of easily wearable exoskeletons. The two categories - rigid and soft exoskeletons - complement each other in their structures during applications. Soft robotic elements enable precise and delicate movements while providing adequate flexibility during use and rigid units are responsible for the stable frame structure and fixation. Their combined use is applied for rehabilitation, occupational safety, and enhancing work performance purposes. The aim of this article is to physically realize a device that has a legitimate purpose in the field of human hand rehabilitation. The goal was to design, manufacture, and functionally test the elements of a device capable of assisting in the rehabilitation of fingers using completely flexible actuators.

4 August 2024 in Analecta Technica Szegedinensia
Verified
Journal Article
Open access
PDF file
Attila MészárosAttila Mészáros
Attila Mészáros
In my imaginations are about all the developments which can be connect with human health.In this study I show what are the main problems with all of the technological developmets all around the globe.There are so many publications which discuss the main problems and they tries to show the solutions, but these are the most difficult problems because the human do not want to leave the easier solutions about his life nowadays. It is enough to mention that the uses of bicycle instead of the cars especially ever since the European Union finished the all around development so bicycle ways in the area of and between the cities in Europen countries. It is important to know, that there are so many talented student in University of Miskolc, at Faculty of Healthcare, for example at Health-visitor and prevention professionals, who interested in in multi-and interdisciplinar borderlines of professionalism between science of health and law and technological science.We have to mention that this study is a begin of a new trend in this Faculty.