Peter Covens

Prof. Dr. Peter Covens

orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2007 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
PCPeter Covens
Peter Covens
DBD. Berus
D. Berus
NBNico Buls
Nico Buls
PCP. Clerinx
P. Clerinx
FVF. Vanhavere
F. Vanhavere
It is known that medical applications using ionising radiation are wide spread and still increasing. Physicians, technicians, nurses and others constitute the largest group of workers occupationally exposed to man-made sources of radiation. Many hospital workers are consequently subjected to routine monitoring of professional radiation exposures. in the university hospital, UZ Brussel, 600 out of 4000 staff members are daily monitored for external radiation exposures. The most obvious applications of ionising radiation are diagnostic radiology, diagnostic or therapeutic use of radionuclides in nuclear medicine and external radiation therapy or brachytherapy in radiotherapy departments. Other important applications also include various procedures in interventional radiology (IR), in vitro biomedical research and radiopharmaceutical production around cyclotrons. Besides the fact that many of the staff members, involved in these applications, are not measurably exposed, detailed studies were carried out at workplaces where routine dose monitoring encounters difficulties and for some applications where relatively high occupational exposures can be found. most of the studies are concentrated around nuclear medicine applications and IR. They contain assessments of both effective dose and doses at different parts of the body. The results contribute to better characterisation of the different workplaces in a way that critical applications can be identified. Moreover, conclusions point out future needs for practical routine dose monitoring and optimisation of radiation protection.

29 July 2020 in Molecular Pharmaceutics
Verified
Journal Article
Closed access
YDYana Dekempeneer
Yana Dekempeneer
VCVicky Caveliers
Vicky Caveliers
MOMaarten Ooms
Maarten Ooms
DMDominic Maertens
Dominic Maertens
MGMireille Gysemans
Mireille Gysemans
MDMatthias D'Huyvetter
Matthias D'Huyvetter

23 March 2010 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
PCPeter Covens
Peter Covens
DBD. Berus
D. Berus
FVF. Vanhavere
F. Vanhavere
VCV. Caveliers
V. Caveliers
Significant staff exposure is generally expected during PET-and PET/CT applications. Whole-body doses as well as extremity doses are usually higher per procedure compared with SPECT applications. Dispensing individual patient doses and manual injection involves high extremity doses even when heavy weighted syringe shields are used. In some cases the external radiation causes an exposure to the fingertips of more than 500 mSv y−1, which is the yearly limit. Whole-body doses per procedure are relatively lower compared with extremity doses and are generally spread over the entire procedure (Guillet, B., Quentin, P., Waultier, S., Bourrelly, M., Pisano, P. and Mundler, O. Technologist radiation exposure in routine clinical practice with 18F-FDG PET. J. Nucl. Med. Technol. 33, 175–179 (2005). Optimisation of the individual workload is often used to restrict staff doses, but many PET centres face the need for further optimisation to reduce the staff doses to an acceptable level. During this study the effect of the use of an automated dispensing and injection system for 18FDG on whole-body doses and extremity doses was evaluated. Detailed dosimetric studies using thermoluminescent and direct ion storage dosimetry were carried out before and after the introduction of this system. The results show that the extremity doses can be reduced by more than 95 % up to a mean level of 10 μSv per handled GBq. At the same time, whole-body doses can be halved during injection of the tracer. This results in a dose reduction of 20 % during the entire procedure of injection, escorting and positioning. In this way, the study shows that with the use of automated dispensing and injection a considerable staff dose reduction can be obtained.

1 July 1992 in Bone
Verified
Journal Article
Closed access
OLO. Louis
O. Louis
PWP. Van Den Winkel
P. Van Den Winkel
PCPeter Covens
Peter Covens
ASA. Schoutens
A. Schoutens
MOM. Osteaux
M. Osteaux

1 December 2021 in Journal of Radiological Protection
Verified
Journal Article
Closed access
RKRobert Kollaard
Robert Kollaard
AZAlessandra Zorz
Alessandra Zorz
JDJérémie Dabin
Jérémie Dabin
PCPeter Covens
Peter Covens
JCJennie Cooke
Jennie Cooke
LMLeanne McNamara
Leanne McNamara
The exposure of the fingers is one of the major radiation protection concerns in nuclear medicine (NM). The purpose of this paper is to provide an overview of the exposure, dosimetry and protection of the extremities in NM. A wide range of reported finger doses were found in the literature. Historically, the highest finger doses are found at the fingertip in the preparation and dispensing of 18 F for diagnostic procedures and 90 Y for therapeutic procedures. Doses can be significantly reduced by following recommendations on source shielding, increasing distance and training. Additionally, important trends contributing to a lower dose to the fingers are the use of automated procedures (especially for positron emission tomography (PET)) and the use of prefilled syringes. On the other hand, the workload of PET procedures has substantially increased during the last ten years. In many cases, the accuracy of dose assessment is limited by the location of the dosimeter at the base of the finger and the maximum dose at the fingertip is underestimated (typical dose ratios between 1.4 and 7). It should also be noted that not all dosimeters are sensitive to low-energy beta particles and there is a risk for underestimation of the finger dose when the detector or its filter is too thick. While substantial information has been published on the most common procedures (using 99m Tc, 18 F and 90 Y), less information is available for more recent applications, such as the use of 68 Ga for PET imaging. Also, there is a need for continuous awareness with respect to contamination of the fingers, as this factor can contribute substantially to the finger dose.

21 September 2022 in Molecular Cancer Therapeutics
Verified
Journal Article
Open access
PDF file
MRMagdalena Rodak
Magdalena Rodak
YDYana Dekempeneer
Yana Dekempeneer
MWMaria Wojewódzka
Maria Wojewódzka
VCVicky Caveliers
Vicky Caveliers
PCPeter Covens
Peter Covens
MPMarek Pruszyński
Marek Pruszyński
Human epidermal growth factor receptor type 2 (HER2) is overexpressed in various cancers; thus, HER2-targeting single-domain antibodies (sdAb) could offer a useful platform for radioimmunotherapy. In this study, we optimized the labeling of an anti-HER2-sdAb with the α-particle-emitter 225Ac through a DOTA-derivative. The formed radioconjugate was tested for binding affinity, specificity and internalization properties, whereas cytotoxicity was evaluated by clonogenic and DNA double-strand-breaks assays. Biodistribution studies were performed in mice bearing subcutaneous HER2pos tumors to estimate absorbed doses delivered to organs and tissues. Therapeutic efficacy and potential toxicity were assessed in HER2pos intraperitoneal ovarian cancer model and in healthy C57Bl/6 mice. [225Ac]Ac-DOTA-2Rs15d exhibited specific cell uptake and cell-killing capacity in HER2pos cells (EC50 = 3.9 ± 1.1 kBq/mL). Uptake in HER2pos lesions peaked at 3 hours (9.64 ± 1.69% IA/g), with very low accumulation in other organs (<1% IA/g) except for kidneys (11.69 ± 1.10% IA/g). α-camera imaging presented homogeneous uptake of radioactivity in tumors, although heterogeneous in kidneys, with a higher signal density in cortex versus medulla. In mice with HER2pos disseminated tumors, repeated administration of [225Ac]Ac-DOTA-2Rs15d significantly prolonged survival (143 days) compared to control groups (56 and 61 days) and to the group treated with HER2-targeting mAb trastuzumab (100 days). Histopathologic evaluation revealed signs of kidney toxicity after repeated administration of [225Ac]Ac-DOTA-2Rs15d. [225Ac]Ac-DOTA-2Rs15d efficiently targeted HER2pos cells and was effective in treatment of intraperitoneal disseminated tumors, both alone and as an add-on combination with trastuzumab, albeit with substantial signs of inflammation in kidneys. This study warrants further development of [225Ac]Ac-DOTA-2Rs15d.