Antithrombogenic coatings of artificial surfaces within extracorporeal membrane oxygenation (ECMO) circuits improved its bio- and hemocompatibility. However, there is still a risk of thrombus formation in particular within the membrane oxygenator (MO). Since inflammatory cells are essential components within clots, the aim was to identify the extent of cellular accumulations on gas exchange capillaries from different ECMO systems. Thirty-four MOs (PLS, n = 27, Getinge; Hilite 7000 LT, n = 7, Fresenius Medical Care, Germany) were collected from adult patients. The extent of cellular deposits on gas exchange capillaries was classified using nuclear 4′,6-diamidino-2-phenylindole staining and fluorescence microscopy. All Hilite oxygenators exhibited small cellular deposits. In contrast, the cellular distribution was heterogeneous on capillaries from PLS oxygenators: small deposits (34%), clusters (44%) and membrane-spanning cell structures (pseudomembranes) (22%). Overall, the median fluorescence intensity was significantly higher in the PLS group. Nevertheless, within 3 days before MO removal, there was no alteration in critical parameters (d-dimer and fibrinogen levels, platelet counts, and pressure drop across the MO). In conclusion, despite the histological differences on the gas capillaries from different types of oxygenators, there was no further evidence of increased inflammation and coagulation parameters that indicate clot formation within oxygenators.
Background: The aim of this study was to evaluate the performance and the impact of contrast-enhanced intraoperative ultrasound (CE-IOUS) on intraoperative decision-making, as there is still no standardized protocol for its use. Therefore, we retrospectively analyzed multiple CE-IOUS performed in hepato-pancreatic-biliary surgery with respect to pre- and postoperative imaging and histopathological findings. Methods: Data of 50 patients who underwent hepato-pancreatic-biliary surgery between 03/2022 and 03/2024 were retrospectively collected. CE-IOUS was performed with a linear 6–9 MHz multifrequency probe connected to a high-resolution device. The ultrasound contrast agent used was a stabilized aqueous suspension of sulphur hexafluoride microbubbles. Results: In total, all 50 lesions indicated for surgery were correctly identified. In 30 cases, CE-IOUS was used to localize the primary lesion and to define the resection margins. In the remaining 20 cases, CE-IOUS identified an additional lesion. Fifteen of these findings were identified as malignant. In eight of these cases, the additional malignant lesion was subsequently resected. In the remaining seven cases, CE-IOUS again revealed an inoperable situation. In summary, CE-IOUS diagnostics resulted in a high correct classification rate of 95.7%, with positive and negative predictive values of 95.2% and 100.0%, respectively. Conclusions: CE-IOUS shows excellent performance in describing intraoperative findings in hepato-pancreatic-biliary surgery, leading to a substantial impact on intraoperative decision-making.
29 September 2024 in Journal of Gastrointestinal and Liver Diseases
Background and Aims: To evaluate, if high frame rate (HiFR) contrast-enhanced ultrasound (CEUS) and external perfusion analysis (VueBox®)can give answers on liver tumour diagnostics. Methods: A multifrequency probe (C1-6 /Resona R9) and 1-2.4 ml ultrasound contrast medium were used for CEUS up to 5-6 min. Independent analysis of DICOM-CINE files was performed, correlated to follow-up, computed tomography, magnetic resonance imaging, or histopathology. Results: In 110 patients the difference between marginal peak enhancement (PE) of malignant and benign leasions was significant. In the peripheral area, the AUCs were lower in malignant lesions (144.8±139.3) than in benign lesions (123.6±119.8). The mean transit time (mTT) was shorter in malignant lesions in the center. In the liver parenchyma, however, the mTT was significantly longer in malignant lesions (141.6±107.9s) than in benign lesions (128.8±138.6 s). The rise time (RT) was significantly shorter central (66.5±30.9s) and peripheral (72.8±35.1s) in malignant lesions than in benign lesions (114.33±159.58s). The wash in rate (WiR) in benign lesions was 848.3±2,563.7 rU in the center. Wash-out rate (WoR) in the center, peripheral and in the liver parenchyma showed a significantly lower wash-out in the malignant lesions. Conclusions: HiFR CEUS with perfusion analysis enables the assessment of focal, diffuse and post-interventional liver changes.
22 December 2023 in Journal of Gastrointestinal and Liver Diseases
Aims: To assess the value of using integrated parametric ultrasound software for contrast-enhanced ultrasonography (CEUS) of liver tumors. Methods: 107 patients with liver tumors were studied. CEUS were performed to detect focal lesions. Parametric images were based on continuous CINE LOOPs, from the early-arterial phase (15 s) to the portal-venous phase (1 min) generated by perfusion software. The evaluations of the parametric images and their dignity for liver lesions were performed independently by an experienced and a less-experienced investigator. Computed tomography, magnetic resonance imaging scans or histological analysis were used as references. Results: High parametric image quality were obtained in all patients. Among the patients, 44% lesions were benign, 56% were malignant. The experienced investigator correctly classified 46 of 47 (98%) as benign, and 60 of 60 (100%) as malignant tumors based on the parametric images. The less-experienced investigator correctly classified 39 of 47 (83%) as benign, and 49 of 60 (82%) malignant tumors, acheaving a high statistical accuracy of 98% with this type of diagnostic. Conclusion: Parametric imaging for grading the malignant degree of tumor may be a good complement to existing ultrasound techniques and was particularly helpful for improving the assessments of the less-experienced examiner.
26 May 2025 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
The purpose of this study was to conduct an intraoperative evaluation of focal liver lesions using time intensity curve (TIC) analysis of contrast-enhanced ultrasound (CEUS) to better assess liver tumor margins. This study included 28 patients (21 men 75%, 7 women 25%) with malignant liver lesions (cholangiocellular carcinoma (CCC), n = 9; hepatocellular carcinoma (HCC), n = 6; hepatic metastases (HepMET), n = 13). A B-mode scan, color-coded Doppler sonography, and CEUS were performed intraoperatively to analyze the focal lesions. The generated parametric images were based on continuous cine loops, acquired with a multifrequency T-probe (6–9 MHz), from the early arterial phase (0–15 seconds) to the portal venous phase (1 minute), generated by integrated perfusion software. Analyses of the CEUS loops were performed using TICs with respect to time-to-peak (TTP) and area under the curve (AUC). Perfusion analysis was performed in the center and periphery of the tumor as well as in healthy liver tissue. All tumor lesions were evaluated histopathologically to verify the diagnosis. Sufficient image quality was achieved in all cases using CEUS for TIC analysis. A comparison of all groups showed a clear difference compared with the center, margin, and healthy liver tissue in the measured parameters of TTP and AUC (p = 0.035 and p = 0.045, respectively). In detail, differences were observed in the CCC group (TTP: p = 0.025) and in the HepMET group (TTP: p = 0.009), particularly in the peripheral areas (strong arterial flooding with a rapid increase in the flooding curve), with equally clear tumor edge representation compared with healthy liver tissue, as shown by the AUC analysis (CCC AUC: p = 0.032 and HepMET AUC: p = 0.029). In patients with HCC, the perfusion pattern (starting from the center) showed the center to be more clearly distinguishable from the edge with significant TTP and AUC (p = 0.035 and p = 0.038). Intraoperative TIC analysis of malignant liver tumors is an important diagnostic tool for better highlighting liver tumor margins during surgery.