Fan Lu

Prof. Dr. Fan Lu


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2021 in British Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
JBJinhua Bao
Jinhua Bao
AYAdeline Yang
Adeline Yang
YHYingying Huang
Yingying Huang
XLXue Li
Xue Li
YPYiguo Pan
Yiguo Pan
HCHao Chen
Hao Chen
Aims To evaluate the 1-year efficacy of two new myopia control spectacle lenses with lenslets of different asphericity. Methods One hundred seventy schoolchildren aged 8–13 years with myopia of −0.75 D to −4.75 D were randomised to receive spectacle lenses with highly aspherical lenslets (HAL), spectacle lenses with slightly aspherical lenslets (SAL), or single-vision spectacle lenses (SVL). Cycloplegic autorefraction (spherical equivalent refraction (SER)), axial length (AL) and best-corrected visual acuity (BCVA) were measured at baseline and 6-month intervals. Adaptation and compliance questionnaires were administered during all visits. Results After 1 year, the mean changes in the SER (±SE) and AL (±SE) in the SVL group were −0.81±0.06 D and 0.36±0.02 mm. Compared with SVL, the myopia control efficacy measured using SER was 67% (difference of 0.53 D) for HAL and 41% (difference of 0.33 D) for SAL, and the efficacy measured using AL was 64% (difference of 0.23 mm) for HAL and 31% (difference of 0.11 mm) for SAL (all p<0.01). HAL resulted in significantly greater myopia control than SAL for SER (difference of 0.21 D, p<0.001) and AL (difference of 0.12 mm, p<0.001). The mean BCVA (−0.01±0.1 logMAR, p=0.22) and mean daily wearing time (13.2±2.6 hours, p=0.26) were similar among the three groups. All groups adapted to their lenses with no reported adverse events, complaints or discomfort. Conclusions Spectacle lenses with aspherical lenslets effectively slow myopia progression and axial elongation compared with SVL. Myopia control efficacy increased with lenslet asphericity. Trial registration number ChiCTR1800017683.

1 November 2016 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
YYYe Yang
Ye Yang
JWJianhua Wang
Jianhua Wang
HJHong Jiang
Hong Jiang
XYXiaoling Yang
Xiaoling Yang
LFLimiao Feng
Limiao Feng
MSMeixiao Shen
Meixiao Shen
Purpose: To investigate the retinal vascular network alterations in highly myopic eyes. Methods: Thirty-three highly myopic eyes from 21 subjects and 47 mildly myopic or emmetropic eyes from 24 healthy control subjects were enrolled. Optical coherence tomography angiography (OCTA) was used to image the superficial, deep, and whole retinal vascular plexuses at the macular region. Highly myopic eye images were analyzed after adjusting the ocular magnification using Bennett's formula. Fractal analysis (box counting method, Dbox) representing vessel density was performed in different annular and quadrantile zones of both large vessels and microvessels. Correlations between the vascular density, axial length, and spherical equivalent refractive error were analyzed. Results: The average density (Dbox) of the superficial retinal annular zone (0.6–2.5 mm) microvessels was 1.741 ± 0.018 in highly myopic eyes and was shown to be significantly lower than that of the controls (1.773 ± 0.010, P < 0.001). Individual annular zone (bandwidth of 0.16 mm) analysis of highly myopic eyes revealed a significant level of microvessel alteration in all zones compared with the same zones in control eyes (P < 0.001). Furthermore, in the highly myopic group, the microvessel density was significantly correlated with axial length elongation in all three layers (r = −0.38 to −0.48; P < 0.05). Conclusions: This study reveals retinal microvascular network alterations in highly myopic eyes, which correlates with axial length elongation. Fractal analysis of the microvasculature by OCTA images may help to characterize the underlying pathophysiological mechanisms involved in high myopia.

1 August 2018 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
WKWilliam Robert Kwapong
William Robert Kwapong
HYHua Ye
Hua Ye
CPChenlei Peng
Chenlei Peng
XZXiran Zhuang
Xiran Zhuang
JWJianhua Wang
Jianhua Wang
FLFan Lu
Fan Lu
Purpose: To detect the retinal microvascular impairment using optical coherence tomography angiography (OCT-A) in patients with Parkinson's disease (PD) and find a correlation between the microvascular impairment and the neuronal damage. Methods: This is a prospective, observational study including 49 eyes from 38 PD patients in their early stages and 34 eyes from 28 healthy controls with comparable age range. Macula microvasculature was evaluated with the spectral-domain optical coherence tomography (SD-OCT) angiography and intraretinal layer thickness evaluated with the SD-OCT. A custom algorithm was used for custom segmentation of retinal thickness and quantification of the superficial and deep microvascular density of the macula, respectively. Results: PD patients showed reduced microvascular density in most of the areas of the whole retina. In the superficial retinal capillary plexus, statistical difference (P < 0.01) was seen in the total annular zone (TAZ), superior, temporal, inferior, and nasal zones. In PD patients, there was a strong correlation between the average ganglion cell layer and inner plexiform (GCIP) thickness and the TAZ of the superficial microvascular density (r = 0.062, P = 0.032). Conclusion: We demonstrated that retinal microvascular density decreased in PD patients. The correlation between microvascular impairment in the superficial retinal capillary layer and GCIP thinning also revealed that the retinal microvascular abnormality may contribute to the neurodegeneration in PD patients. OCT-A with quantitative analysis offers a new path of study and will likely be useful in the future as an objective biomarker for detecting vessel impairment in early stages of PD.

1 July 2015 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
XLXinting Liu
Xinting Liu
MSMeixiao Shen
Meixiao Shen
YYYimin Yuan
Yimin Yuan
SHShenghai Huang
Shenghai Huang
DZDexi Zhu
Dexi Zhu
FLFan Lu
Fan Lu

9 April 2020 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
JYJie Ye
Jie Ye
MWMengyi Wang
Mengyi Wang
MSMeixiao Shen
Meixiao Shen
SHShenghai Huang
Shenghai Huang
AXAnquan Xue
Anquan Xue
YSYilei Shao
Yilei Shao
Purpose: The purpose of this study was to measure alterations of inner retinal microvascular density and outer retinal sublayer thicknesses in pathological myopia, and to correlate the measured parameters with best corrected visual acuity (BCVA). Methods: Optical coherence tomography (OCT) and OCT angiography (OCTA) images of 21 control, 48 simple high myopia, and 22 pathological myopia eyes were analyzed to quantify the thicknesses of the outer retinal sublayers and the density of the inner retinal microvascular network that includes the superficial retinal capillary plexus (SRCP) and deep retinal capillary plexus (DRCP). Retinal sublayer thicknesses and microvascular densities were compared among the three groups, and correlations of sublayer thicknesses and microvascular densities with BCVA were determined. Results: In pathological myopia, density of the DRCP, thicknesses of myoid and ellipsoid zone (MEZ), interdigitation zone and retinal pigment epithelium/Bruch complex (IZ + RPE), and choroid were lower than in simple high myopia (P < 0.05). The decreased DRCP density was correlated with thinner MEZ and IZ+RPE in pathological myopia (P < 0.05), but not in simple high myopia (P > 0.05). Simple linear regression showed that axial length, female, thicknesses of outer plexiform layer (OPL), MEZ, IZ + RPE, choroid, and density of the SRCP and DRCP were correlated with BCVA. In multiple regression analysis, worse BCVA was associated only with thinner MEZ, thinner choroid, and decreased DRCP (P < 0.05). Conclusions: Alteration of inner retinal microvascular density and outer retinal sublayer thicknesses occurred in pathological myopia, especially decreased DRCP and thinner MEZ, which were significantly associated with worse BCVA.

15 November 2022 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
YWYiyi Wang
Yiyi Wang
SCSisi Chen
Sisi Chen
JLJue Lin
Jue Lin
WCWen Chen
Wen Chen
HHHuimin Huang
Huimin Huang
YSYilei Shao
Yilei Shao
Purpose: Photoreceptor loss plays a role in visual impairment in pathological myopia. As the nutrition and oxygen demands of photoreceptors are mainly supported by the choroidal vessels, we aimed to investigate changes in the choroidal vasculature and their correlations with visual acuity in pathological myopia. Methods: The cohort was composed of 136 eyes from 80 participants, including 42 eyes from 21 participants with emmetropia/low myopia, 48 eyes from 26 participants with simple high myopia, and 46 eyes from 33 participants with pathological myopia. Swept-source optical coherence tomography (OCT) was used to image the eyes with a 12-mm radial line scan protocol. The parameters for 6-mm diameters of macula area centered on the fovea were analyzed. A custom deep learning algorithm based on a modified residual U-Net architecture was used to segment the choroidal boundaries. Then, the distance between the two boundaries was determined and choroidal thickness (CT), luminal area (LA), and stromal area (SA) were demarcated based on Niblack's auto-local threshold algorithm after binarization of the OCT images. Finally, the ratio of LA and total choroidal area was defined as the choroidal vascularity index (CVI). The choroidal parameters in three groups were compared, and correlations of the choroidal parameters with age, gender, axial length, and best-corrected visual acuity (BCVA) were analyzed. Results: The CVI, CT, LA, and SA values were lower in pathological myopia than in emmetropia/low myopia and simple high myopia (P < 0.05). The CT, LA, and SA values were lower in simple high myopia than in emmetropia/low myopia (P < 0.05), whereas there was no difference between the CVIs in the emmetropia/low myopia and high myopia groups (P > 0.05). The CVI was nonlinear with increases in axial length (AL), and there was a critical AL flexion point, approximately 27.26 mm; however, the CT, LA, and SA were negatively correlated with AL. Further analysis showed that only younger subjects (40 years old or less) showed significant AL flexion points. Simple and multiple regression models showed that the CVI was correlated with BCVA (P < 0.05). Conclusions: Choroidal vascular alterations, especially decreased CVI, occurred in patients with pathological myopia. The CVI decreased with axial elongation beyond the flexion point and was correlated with visual impairment, indicating that the CVI might be a reliable imaging biomarker to monitor the progression of pathological myopia.