Aneta Liszka

Mrs. Aneta Liszka

Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Östergötland, Sweden
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2016 in ACS Biomaterials Science & Engineering
Verified
Journal Article
Closed access
GTGopi Krishna Tummala
Gopi Krishna Tummala
TJThomas Joffre
Thomas Joffre
VLViviana Lopes
Viviana Lopes
ALAneta Liszka
Aneta Liszka
OBOleksiy Buznyk
Oleksiy Buznyk
AMAlbert Mihranyan
Albert Mihranyan

1 March 2018 in Acta Biomaterialia
Verified
Journal Article
Open access
JJJaganmohan R. Jangamreddy
Jaganmohan R. Jangamreddy
MHMichel K.C. Haagdorens
Michel K.C. Haagdorens
MIM. Mirazul Islam
M. Mirazul Islam
PLPhilip Lewis
Philip Lewis
ASAyan Samanta
Ayan Samanta
MGMay Griffith
May Griffith
Short collagen-like peptides (CLPs) are being proposed as alternatives to full-length collagen for use in tissue engineering, on their own as soft hydrogels, or conjugated to synthetic polymer for mechanical strength. However, despite intended clinical use, little is known about their safety and efficacy, mechanism of action or degree of similarity to the full-length counterparts they mimic. Here, we show the functional equivalence of a CLP conjugated to polyethylene glycol (CLP-PEG) to full-length recombinant human collagen in vitro and in promoting stable regeneration of corneal tissue and nerves in a pre-clinical mini-pig model. We also show that these peptide analogs exerted their pro-regeneration effects through stimulating extracellular vesicle production by host cells. Our results support future use of CLP-PEG implants for corneal regeneration, suggesting the feasibility of these or similar peptide analogs in clinical application in the eye and other tissues. Although biomaterials comprising full-length recombinant human collagen and extracted animal collagen have been evaluated and used clinically, these macromolecules provide only a limited number of functional groups amenable to chemical modification or crosslinking and are demanding to process. Synthetic, customizable analogs that are functionally equivalent, and can be readily scaled-up are therefore very desirable for pre-clinical to clinical translation. Here, we demonstrate, using cornea regeneration as our test bed, that collagen-like-peptides conjugated to multifunctional polyethylene glycol (CLP-PEG) when grafted into mini-pigs as corneal implants were functionally equivalent to recombinant human collagen-based implants that were successfully tested in patients. We also show for the first time that these materials affected regeneration through stimulation of extracellular vesicle production by endogenous host cells that have migrated into the CLP-PEG scaffolds.

19 January 2020 in The FASEB Journal
Verified
Journal Article
Closed access
PDF file
CBCornelia Bratengeier
Cornelia Bratengeier
ALAneta Liszka
Aneta Liszka
JHJohan Hoffman
Johan Hoffman
ABAstrid D. Bakker
Astrid D. Bakker
AFAnna Fahlgren
Anna Fahlgren

21 May 2021 in Communications Biology
Verified
Journal Article
Open access
PDF file
FSFiona C. Simpson
Fiona C. Simpson
CMChristopher D. McTiernan
Christopher D. McTiernan
MIMohammad Mirazul Islam
Mohammad Mirazul Islam
OBOleksiy Buznyk
Oleksiy Buznyk
PLPhilip N. Lewis
Philip N. Lewis
MGMay Griffith
May Griffith
The long-term survival of biomaterial implants is often hampered by surgery-induced inflammation that can lead to graft failure. Considering that most corneas receiving grafts are either pathological or inflamed before implantation, the risk of rejection is heightened. Here, we show that bioengineered, fully synthetic, and robust corneal implants can be manufactured from a collagen analog (collagen-like peptide-polyethylene glycol hybrid, CLP-PEG) and inflammation-suppressing polymeric 2-methacryloyloxyethyl phosphorylcholine (MPC) when stabilized with the triazine-based crosslinker 4-(4,6-Dimethoxy-1,3,5-triazin-2-yl)-4-methylmorpholinium chloride. The resulting CLP-PEG-MPC implants led to reduced corneal swelling, haze, and neovascularization in comparison to CLP-PEG only implants when grafted into a mini-pig cornea alkali burn model of inflammation over 12 months. Implants incorporating MPC allowed for faster nerve regeneration and recovery of corneal sensation. CLP-PEG-MPC implants appear to be at a more advanced stage of regeneration than the CLP-PEG only implants, as evidenced by the presence of higher amounts of cornea-specific type V collagen, and a corresponding decrease in the presence of extracellular vesicles and exosomes in the corneal stroma, in keeping with the amounts present in healthy, unoperated corneas.

28 November 2023 in The FASEB Journal
Verified
Journal Article
Open access
CBCornelia Bratengeier
Cornelia Bratengeier
LJL. Johansson
L. Johansson
ALAneta Liszka
Aneta Liszka
Astrid BakkerAstrid Bakker
Astrid Bakker
MHM. Hallbeck
M. Hallbeck
AFA. Fahlgren
A. Fahlgren
Low‐intensity loading maintains or increases bone mass, whereas lack of mechanical loading and high‐intensity loading decreases bone mass, possibly via the release of extracellular vesicles by mechanosensitive bone cells. How different loading intensities alter the biological effect of these vesicles is not fully understood. Dynamic fluid shear stress at low intensity (0.7 ± 0.3 Pa, 5 Hz) or high intensity (2.9 ± 0.2 Pa, 1 Hz) was used on mouse hematopoietic progenitor cells for 2 min in the presence or absence of chemical compounds that inhibit release or biogenesis of extracellular vesicles. We used a Receptor activator of nuclear factor kappa‐Β ligand‐induced osteoclastogenesis assay to evaluate the biological effect of different fractions of extracellular vesicles obtained through centrifugation of medium from hematopoietic stem cells. Osteoclast formation was reduced by microvesicles (10 000× g ) obtained after low‐intensity loading and induced by exosomes (100 000× g ) obtained after high‐intensity loading. These osteoclast‐modulating effects could be diminished or eliminated by depletion of extracellular vesicles from the conditioned medium, inhibition of general extracellular vesicle release, inhibition of microvesicle biogenesis (low intensity), inhibition of ESCRT‐independent exosome biogenesis (high intensity), as well as by inhibition of dynamin‐dependent vesicle uptake in osteoclast progenitor cells. Taken together, the intensity of mechanical loading affects the release of extracellular vesicles and change their osteoclast‐modulating effect.

5 June 2023 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
KMKamal Malhotra
Kamal Malhotra
OBOleksiy Buznyk
Oleksiy Buznyk
MIMohammad Mirazul Islam
Mohammad Mirazul Islam
EEElle Edin
Elle Edin
Sankar BasuSankar Basu
Sankar Basu
MGMay Griffith
May Griffith
Severe HSV-1 infection can cause blindness due to tissue damage from severe inflammation. Due to the high risk of graft failure in HSV-1-infected individuals, cornea transplantation to restore vision is often contraindicated. We tested the capacity for cell-free biosynthetic implants made from recombinant human collagen type III and 2-methacryloyloxyethyl phosphorylcholine (RHCIII-MPC) to suppress inflammation and promote tissue regeneration in the damaged corneas. To block viral reactivation, we incorporated silica dioxide nanoparticles releasing KR12, the small bioactive core fragment of LL37, an innate cationic host defense peptide produced by corneal cells. KR12 is more reactive and smaller than LL37, so more KR12 molecules can be incorporated into nanoparticles for delivery. Unlike LL37, which was cytotoxic, KR12 was cell-friendly and showed little cytotoxicity at doses that blocked HSV-1 activity in vitro, instead enabling rapid wound closure in cultures of human epithelial cells. Composite implants released KR12 for up to 3 weeks in vitro. The implant was also tested in vivo on HSV-1-infected rabbit corneas where it was grafted by anterior lamellar keratoplasty. Adding KR12 to RHCIII-MPC did not reduce HSV-1 viral loads or the inflammation resulting in neovascularization. Nevertheless, the composite implants reduced viral spread sufficiently to allow stable corneal epithelium, stroma, and nerve regeneration over a 6-month observation period.