Qiongfang Wang

Dr. Qiongfang Wang


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Ecotoxicology and Environmental Safety
Verified
Journal Article
Closed access
QWQiongfang Wang
Qiongfang Wang
PRPinhua Rao
Pinhua Rao
GLGuanghui Li
Guanghui Li
LDLei Dong
Lei Dong
XZXin Zhang
Xin Zhang
JDJing Deng
Jing Deng

11 August 2022 in Science of The Total Environment
Verified
Journal Article
Closed access
ZHZedi He
Zedi He
QWQiongfang Wang
Qiongfang Wang
PRPinhua Rao
Pinhua Rao
LDLei Dong
Lei Dong
MZMin Zhang
Min Zhang
JDJing Deng
Jing Deng

20 November 2022 in Water
Verified
Journal Article
Open access
PDF file
WLwanting Li
wanting Li
SSShihu Shu
Shihu Shu
YZYanping Zhu
Yanping Zhu
LWLinjing Wu
Linjing Wu
QWQiongfang Wang
Qiongfang Wang
NGNaiyun Gao
Naiyun Gao
UV/chlorine advanced oxidation process (AOP), as a potential alternative to UV/H2O2 in water treatment, may pose a potential risk of increased disinfection by-product (DBP) formation and is of great concern. In this paper, seven benzene derivatives, containing two chlorine-inert and five chlorine-active compounds, were selected as typical model DBP precursors, and the effects of medium pressure UV/chlorine (MPUV/chlorine) on their chlorine demand and DBP formation potential (DBPFP) were evaluated. The results showed that MPUV/chlorine could significantly increase the chlorine demand and DBPFP of the two inert precursors. For the four slow but active DBP precursors, MPUV/chlorine may accelerate their short-term DBP formation, whereas it showed an insignificant effect or even reduced their chlorine demand and DBPFP. For the only fast and active DBP precursor, MPUV/chlorine showed an insignificant effect on its short-term DBP formation or DBPFP. The overall effect of MPUV/chlorine was more significant at pH 6 than at pH 8. In the presence of Br−, MPUV/chlorine significantly increased the bromine substitution factors of THMs. In addition, linear fitting results indicated that the UV/chlorine-induced change in overall chlorine demand may be considered as a potential indicator for the prediction of DBPFP alteration.

22 June 2022 in Catalysts
Verified
Journal Article
Open access
PDF file
YJYu Jiali
Yu Jiali
SSShihu Shu
Shihu Shu
QWQiongfang Wang
Qiongfang Wang
NGNaiyun Gao
Naiyun Gao
YZYanping Zhu
Yanping Zhu
In this work, the degradation performance of Fe2+/PAA/H2O2 on three typical pollutants (reactive black 5, ANL, and PVA) in textile wastewater was investigated in comparison with Fe2+/H2O2. Therein, Fe2+/PAA/H2O2 had a high removal on RB5 (99%) mainly owing to the contribution of peroxyl radicals and/or Fe(IV). Fe2+/H2O2 showed a relatively high removal on PVA (28%) mainly resulting from ·OH. Fe2+/PAA/H2O2 and Fe2+/H2O2 showed comparative removals on ANL. Additionally, Fe2+/PAA/H2O2 was more sensitive to pH than Fe2+/H2O2. The coexisting anions (20–2000 mg/L) showed inhibition on their removals and followed an order of HCO3− > SO42− > Cl−. Humic acid (5 and 10 mg C/L) posed notable inhibition on their removals following an order of reactive black 5 (RB5) > ANL > PVA. In practical wastewater effluent, PVA removal was dramatically inhibited by 88%. Bioluminescent bacteria test results suggested that the toxicity of Fe2+/PAA/H2O2 treated systems was lower than that of Fe2+/H2O2. RB5 degradation had three possible pathways with the proposed mechanisms of hydroxylation, dehydrogenation, and demethylation. The results may favor the performance evaluation of Fe2+/PAA/H2O2 in the advanced treatment of textile wastewater.

20 June 2016 in Desalination and Water Treatment
Verified
Journal Article
Open access
XWXingya Wei
Xingya Wei
NGNaiyun Gao
Naiyun Gao
CLChangjun Li
Changjun Li
JDJing Deng
Jing Deng
YZYanping Zhu
Yanping Zhu
QWQiongfang Wang
Qiongfang Wang
The adsorption of bentazon on two types of granular activated carbons (GACs), VRU F36X16 (VRU) and WS-480 (WS) from aqueous solution was evaluated by kinetics, isotherms, and thermodynamic models in this study. The impacts of initial bentazon concentration, temperature, and initial solution pH were also investigated. The equilibrium adsorption capacity (qe) of each GAC was appreciable under the experimental condition, especially VRU. For either GAC, the adsorption process fitted pseudo-second-order equation best and statistics matched two-step intra-particle diffusion model well. Dubinin–Radushkevich model was the most suitable one for bentazon adsorption on VRU, while Redlich and Peterson model best described bentazon adsorption on WS. Both for VRU and WS, the adsorption process was exothermic and belonged to physisorption. The qe of VRU and WS increased as initial bentazon concentration increased, though the removal rate of bentazon decreased. 25°C was the optimal condition for bentazon adsorption on either GAC, while the qe of both GACs dropped as the temperature increased. Although the increase in pH could hinder bentazon adsorption on GACs significantly, there was a slight change in the adsorption capacities of VRU and WS when initial solution pH was in the range 5–9.

15 May 2023 in Environmental Science: Water Research & Technology
Verified
Journal Article
Closed access
PDF file
RZRuihua Zhang
Ruihua Zhang
CPCheng Peng
Cheng Peng
QWQiongfang Wang
Qiongfang Wang
XZXinyu Zou
Xinyu Zou
QZQiming Zhao
Qiming Zhao
NGNaiyun Gao
Naiyun Gao
In this work, UV/NH2Cl was utilized to remove ciprofloxacin (CIP) from water and the formation of disinfection by-products (DBPs) following disinfection was investigated to determine its applicability and safety. It was demonstrated that the degradation of CIP in UV/NH2Cl was significantly more effective than that in NH2Cl oxidation alone or UV alone. The presence of NOM (0–8 mg L−1), CO3 2− (0–8 mM), and NO3 − (0–8 mM) inhibited CIP degradation with kobs,CIP from 0.030 to 0.012, 0.017, and 0.020 min−1, respectively. In contrast, the NH2Cl concentration (0.25–2 mM) and Cl− (0–8 mM) promoted the degradation of CIP with kobs,CIP increasing from 0.022–0.054 min−1 and 0.030–0.034 min−1. HCO3 − had dual effects on the degradation of CIP. pH slightly affected the degradation of CIP by UV/NH2Cl in near neutral pH range but greatly inhibited it under strong acidic and alkaline conditions. The reaction rate constant of CIP and HO˙ was calculated to be kHO˙,CIP = 3.0 × 109 M−1 s−1 and the contribution of the reactive chlorine species and reactive nitrogen species to CIP degradation was much greater than that of HO˙. Intermediate products of CIP were identified and analyzed to propose 3 possible degradation pathways. The formation of DBPs with NH2Cl disinfection was lower than that with NaClO disinfection after the oxidation of UV/NH2Cl. Briefly, this study provides much useful information for a better understanding of the UV/NH2Cl process for water treatment.