Shihu Shu

Prof. Dr. Shihu Shu


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2022 in Science of The Total Environment
Verified
Journal Article
Closed access
YZYanping Zhu
Yanping Zhu
WLWanting Li
Wanting Li
SSShihu Shu
Shihu Shu
QWQiongfang Wang
Qiongfang Wang
NGNaiyun Gao
Naiyun Gao

9 February 2024 in Water
Verified
Journal Article
Open access
PDF file
BDBo Dong
Bo Dong
SSShihu Shu
Shihu Shu
DLDengxin Li
Dengxin Li
This study introduces an innovative approach for leak detection in water distribution systems (WDSs), integrating three-order embedding, k-means clustering, and long short-term memory (LSTM) networks, with pressure-sensitive analysis techniques. This comprehensive methodology segments the network into distinct partitions, utilizes simulated leak events to train the deep learning networks, and establishes a sophisticated model for accurately identifying leak partitions. This approach generates a leak dataset by adjusting water demands, which could effectively pinpoint the leaks in a specific partition by leveraging both the pressure sensitivity and spatial coordinates of nodes, allowing for the elimination of the need for manual work and precise identification of leaks in targeted areas. Through the analysis of two case studies, the model demonstrates its ability to effectively pinpoint potential leak partitions, significantly enhancing operational efficiency and reliability in managing the complex problems of urban water resource management. This approach not only optimizes leak detection but also paves the way for advanced, data-driven strategies in WDSs, ensuring sustainable and secure water distribution in urban settings.

20 November 2022 in Water
Verified
Journal Article
Open access
PDF file
WLwanting Li
wanting Li
SSShihu Shu
Shihu Shu
YZYanping Zhu
Yanping Zhu
LWLinjing Wu
Linjing Wu
QWQiongfang Wang
Qiongfang Wang
NGNaiyun Gao
Naiyun Gao
UV/chlorine advanced oxidation process (AOP), as a potential alternative to UV/H2O2 in water treatment, may pose a potential risk of increased disinfection by-product (DBP) formation and is of great concern. In this paper, seven benzene derivatives, containing two chlorine-inert and five chlorine-active compounds, were selected as typical model DBP precursors, and the effects of medium pressure UV/chlorine (MPUV/chlorine) on their chlorine demand and DBP formation potential (DBPFP) were evaluated. The results showed that MPUV/chlorine could significantly increase the chlorine demand and DBPFP of the two inert precursors. For the four slow but active DBP precursors, MPUV/chlorine may accelerate their short-term DBP formation, whereas it showed an insignificant effect or even reduced their chlorine demand and DBPFP. For the only fast and active DBP precursor, MPUV/chlorine showed an insignificant effect on its short-term DBP formation or DBPFP. The overall effect of MPUV/chlorine was more significant at pH 6 than at pH 8. In the presence of Br−, MPUV/chlorine significantly increased the bromine substitution factors of THMs. In addition, linear fitting results indicated that the UV/chlorine-induced change in overall chlorine demand may be considered as a potential indicator for the prediction of DBPFP alteration.

12 April 2023 in Processes
Verified
Journal Article
Open access
PDF file
YZYanping Zhu
Yanping Zhu
YCYuxuan Cao
Yuxuan Cao
SSShihu Shu
Shihu Shu
PZPengjin Zhu
Pengjin Zhu
Dongqi WangDongqi Wang
Dongqi Wang
DCDongqing Cai
Dongqing Cai
In this work, the performance of medium-pressure UV/peracetic acid (MPUV/PAA/H2O2) was explored on removing reactive black 5 (RB5), aniline (ANL), and polyvinyl alcohol (PVA), three typical refractory contaminants in printing and dyeing wastewater, compared with MPUV/H2O2. MPUV/PAA/H2O2 showed 75.0, 44.9, and 57.7% removals of RB5, ANL, and PVA, respectively, within 5 min. The removal of RB5 increased from 68.98 to 91.2%, with pH increasing from 6 to 9, while the removals of ANL and PVA were much less pH-dependent. Quenching experiment results indicated that UV photolysis and radical (i.e., •OH and R-C•) oxidation contributed to RB5 removal, while PAA showed high activity in the oxidation of ANL. For PVA, •OH oxidation and UV photolysis were likely the main mechanisms. The coexisting natural organic matter had a negative effect on the degradation of RB5 and PVA. In addition, MPUV/PAA/H2O2 could effectively degrade those pollutants without increasing the toxicity. This work provides a theoretical reference for the utilization of MPUV/PAA/H2O2 in removing structurally diverse refractory contaminants from printing and dyeing wastewater.

22 June 2022 in Catalysts
Verified
Journal Article
Open access
PDF file
YJYu Jiali
Yu Jiali
SSShihu Shu
Shihu Shu
QWQiongfang Wang
Qiongfang Wang
NGNaiyun Gao
Naiyun Gao
YZYanping Zhu
Yanping Zhu
In this work, the degradation performance of Fe2+/PAA/H2O2 on three typical pollutants (reactive black 5, ANL, and PVA) in textile wastewater was investigated in comparison with Fe2+/H2O2. Therein, Fe2+/PAA/H2O2 had a high removal on RB5 (99%) mainly owing to the contribution of peroxyl radicals and/or Fe(IV). Fe2+/H2O2 showed a relatively high removal on PVA (28%) mainly resulting from ·OH. Fe2+/PAA/H2O2 and Fe2+/H2O2 showed comparative removals on ANL. Additionally, Fe2+/PAA/H2O2 was more sensitive to pH than Fe2+/H2O2. The coexisting anions (20–2000 mg/L) showed inhibition on their removals and followed an order of HCO3− > SO42− > Cl−. Humic acid (5 and 10 mg C/L) posed notable inhibition on their removals following an order of reactive black 5 (RB5) > ANL > PVA. In practical wastewater effluent, PVA removal was dramatically inhibited by 88%. Bioluminescent bacteria test results suggested that the toxicity of Fe2+/PAA/H2O2 treated systems was lower than that of Fe2+/H2O2. RB5 degradation had three possible pathways with the proposed mechanisms of hydroxylation, dehydrogenation, and demethylation. The results may favor the performance evaluation of Fe2+/PAA/H2O2 in the advanced treatment of textile wastewater.

19 September 2024 in Water
Verified
Journal Article
Open access
PDF file
BDBo Dong
Bo Dong
SSShihu Shu
Shihu Shu
DLDengxin Li
Dengxin Li
This research explores the strategic optimization of secondary chlorination in water distribution systems (WDSs), in order to enhance the efficiency of disinfection while mitigating odor and operational costs and promoting sustainability in water quality management. The methodology integrates EPANET simulations for water hydraulic and quality modeling with a deep belief network (DBN) within the deep learning framework for accurate chloric odor prediction. Utilizing the non-dominated sorting genetic algorithm-II (NSGA-II), this methodology systematically balances the objectives of chloride dosage and chloramine formation. It combines a chloric odor intensity assessment, a multi-component kinetic model, and dual-objective optimization to conduct a comparative analysis of case studies on secondary chlorination strategies. The optimal configuration with five secondary chlorination stations reduced chloric odor intensity to 1.20 at a cost of USD 40,020.77 per year in Network A while, with eight stations, chloric odor intensity was reduced to 0.88 at a cost of USD 71,405.38 per year in Network B. The results demonstrate a balanced trade-off between odor intensity and operational cost on one hand and sustainability on the other hand, highlighting the importance of precise chlorine management to improve both the sensory and safety qualities of drinking water while ensuring the sustainable use and management of water resources.