Bailin Zhang

Dr. Bailin Zhang


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2023 in Processes
Verified
Journal Article
Open access
PDF file
XZXiaogang Zhang
Xiaogang Zhang
XZXinghua Zhang
Xinghua Zhang
SGShaocheng Ge
Shaocheng Ge
BZBailin Zhang
Bailin Zhang
In order to effectively control high temperatures inside coal gangue hills, gravity heat pipes with specific spacings are vertically installed in coal gangue hills. Heat extracted from these heat pipes can be utilized for power generation through energy conversion. In this study, an equivalent model of gravity heat pipes in coal gangue hills was established and, in a laboratory setting, experimental research and optimization were conducted on power generation per unit area using the temperature difference of gravity heat pipes for electricity generation. To facilitate real-time testing of different heat pipe parameters and to display the experimental results, a multi-parameter measurement system was designed and constructed. This study systematically investigated the effects of various structural parameters such as inclination angle, heating temperature, initial absolute pressure, and working fluid height. Through single-factor experiments, it was determined that the inclination angle had no significant impact. The range of values for heating temperature, initial absolute pressure, and working fluid height were confirmed based on six sets of experiments. To maximize the performance of the thermoelectric generator, a response surface analysis experiment was conducted using the Design-Expert software. The optimal conditions were determined to be a working fluid height of 200.001 mm, an initial absolute pressure of 0.002 MPa, and a heating temperature of 413.15 K. Under these conditions, the power generation per unit area of the thermoelectric generator reached 0.122981 W/(m2·K). The accuracy of the theoretical experiments was verified through on-site industrial experiments. By calculations, it was determined that the maximum temperature difference power generation capacity per gravity heat pipe was 42.39 W. This provides a new solution for the management of coal mine gangue hills and the secondary utilization of waste energy.

21 January 2024 in Journal of Dispersion Science and Technology
Verified
Journal Article
Closed access
ZCZekun Cao
Zekun Cao
BZBailin Zhang
Bailin Zhang
RZRunxu Zhang
Runxu Zhang
XZXinghua Zhang
Xinghua Zhang
LWLei Wang
Lei Wang
JZJian Zhou
Jian Zhou

29 April 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
XZXiaogang Zhang
Xiaogang Zhang
XZXinghua Zhang
Xinghua Zhang
SGShaocheng Ge
Shaocheng Ge
BZBailin Zhang
Bailin Zhang
DZDongguang Zhang
Dongguang Zhang
JYJiayi Yang
Jiayi Yang
Monitoring the temperature of the coal gangue mountains is fundamental to preventing their spontaneous combustion. However, the existing temperature monitoring systems fail to achieve stable, pollution-free temperature monitoring without affecting vegetation growth in these mountains. To address this issue, this work proposes a flexible thermoelectric device (FTD) based on a protrusion-structured liquid metal elastomer (LME). Utilizing a high-thermal-conductivity LME, the FTD adheres closely to the surface of the gravity heat pipe (GHP), ensuring compatibility between FTD and the curved surface of the GHP. Simultaneously, employing a low-thermal-conductivity elastomer helps concentrate heat onto FTD, thereby enhancing thermoelectric power generation efficiency. Additionally, the impact of the shape, size, and height of the protrusion structure at the cold end of the GHP on its efficiency was also investigated. The practical application of FTD on GHP was demonstrated.

12 March 2025 in Scientific Reports
Verified
Journal Article
Open access
HHHaoran Hu
Haoran Hu
BZBailin Zhang
Bailin Zhang
XZXinghua Zhang
Xinghua Zhang
YZYong Zhu
Yong Zhu
LLLusen Luo
Lusen Luo
When auxiliary tunnels pass through gas-bearing strata, there is a risk of gas explosion, but there is less analysis on the impact of gas explosions on operating railways after the auxiliary tunnels are sealed post-construction. To address the shortcomings of existing research, this paper establishes a numerical model of intersecting tunnels that closely resembles actual conditions. It first studies the law of gas explosion in the closed tunnel, obtaining the overpressure curve of the gas explosion. Based on this, the evolution law of plastic expansion of blocking walls of different thicknesses and at different positions under explosive impact is derived, and the safe thickness of the blocking wall is fitted. The study shows that: in the sealed auxiliary tunnel after construction, the overpressure of the gas explosion initially tends to be stable, then increases rapidly, and finally tends to be stable, with the peak value being up to 0.79 MPa. The duration of the explosion increases with the increase of the tunnel length, and the explosion pressure decreases as the tunnel length increases; under the condition of the highest explosion pressure, the maximum deformation of the blocking wall after the gas explosion is 36.7 mm, the shear strain at the center position of the wall surface is the largest, and the range of tensile shear damage is larger, which is a severely damaged area. The final determination establishes that the minimum safe thickness of the wall is 8.33 m.

12 August 2023 in Processes
Verified
Journal Article
Open access
PDF file
BZBailin Zhang
Bailin Zhang
SFShuhua Fang
Shuhua Fang
SZSonglin Zhang
Songlin Zhang
RZRunxu Zhang
Runxu Zhang
YZYu Zang
Yu Zang
As an efficient heat exchange component, the gravity heat pipe can effectively control the accumulated temperature inside gangue dumps and enable reuse of transferred heat. This study establishes a similar simulation experimental platform for gravity heat pipes to control gangue dumps and thermoelectric generation. The influence of wind speed on the start-up performance and isothermal performance of gravity heat pipes is analyzed, along with the impact of wind speed on their thermoelectric generation performance. Initially, the optimal working fluid height and heating height are determined, followed by a comparison and analysis of the isothermal performance, start-up performance, and thermoelectric generation performance of the gravity heat pipe under different wind speeds. The results indicate that at a wind speed of 1.0 m/s, the gravity heat pipe exhibits better start-up and isothermal performance. At a wind speed of 2.0 m/s, the thermoelectric power generation reaches its peak. In the range of 1.0~2.0 m/s wind speeds, the curve of thermoelectric generation exhibits the most fluctuations.

21 July 2024 in Journal of Dispersion Science and Technology
Verified
Journal Article
Closed access
ZCZekun Cao
Zekun Cao
BZBailin Zhang
Bailin Zhang
XZXinghua Zhang
Xinghua Zhang
HWHua Wu
Hua Wu
AXAihao Xie
Aihao Xie
GLGenyuan Liu
Genyuan Liu