In order to effectively control high temperatures inside coal gangue hills, gravity heat pipes with specific spacings are vertically installed in coal gangue hills. Heat extracted from these heat pipes can be utilized for power generation through energy conversion. In this study, an equivalent model of gravity heat pipes in coal gangue hills was established and, in a laboratory setting, experimental research and optimization were conducted on power generation per unit area using the temperature difference of gravity heat pipes for electricity generation. To facilitate real-time testing of different heat pipe parameters and to display the experimental results, a multi-parameter measurement system was designed and constructed. This study systematically investigated the effects of various structural parameters such as inclination angle, heating temperature, initial absolute pressure, and working fluid height. Through single-factor experiments, it was determined that the inclination angle had no significant impact. The range of values for heating temperature, initial absolute pressure, and working fluid height were confirmed based on six sets of experiments. To maximize the performance of the thermoelectric generator, a response surface analysis experiment was conducted using the Design-Expert software. The optimal conditions were determined to be a working fluid height of 200.001 mm, an initial absolute pressure of 0.002 MPa, and a heating temperature of 413.15 K. Under these conditions, the power generation per unit area of the thermoelectric generator reached 0.122981 W/(m2·K). The accuracy of the theoretical experiments was verified through on-site industrial experiments. By calculations, it was determined that the maximum temperature difference power generation capacity per gravity heat pipe was 42.39 W. This provides a new solution for the management of coal mine gangue hills and the secondary utilization of waste energy.
As an effective measure for the rapid fracturing of coal and rock, electric pulse fracture technology has been successfully applied in oil extraction and natural gas discharge. Using the electric pulse fracture mechanism, this technology can be applied to grouting reinforcement to improve the infiltration efficiency of grouting. In this study, we used a numerical simulation method to establish numerical models with different electric pulse peak pressures, different grouting times and different drilling spacing conditions Through numerical simulation studies, we found that the influence range of grouting reinforcement grows with the increased maximum pressure generated by the electrical pulse. The most economical and reasonable electric pulse parameter setting is 5 MPa for static grouting pressure and 100 MPa for peak electric pulse pressure. The best grouting time to keep pressure in the borehole is determined as 9 h, and the best borehole interval is 10 m. In addition, through the treatment of the soft roof of the Caojiashan coal mine, we also found that the reinforcement sample within the grouting reinforcement range had a compressive strength of more than 1.1 MPa; after each grouting reinforcement was completed, the hydraulic bracket could advance 12 m each time, which shows that the electric pulse grouting reinforcement technology has an obvious effect on the treatment of soft roof slab.
Monitoring the temperature of the coal gangue mountains is fundamental to preventing their spontaneous combustion. However, the existing temperature monitoring systems fail to achieve stable, pollution-free temperature monitoring without affecting vegetation growth in these mountains. To address this issue, this work proposes a flexible thermoelectric device (FTD) based on a protrusion-structured liquid metal elastomer (LME). Utilizing a high-thermal-conductivity LME, the FTD adheres closely to the surface of the gravity heat pipe (GHP), ensuring compatibility between FTD and the curved surface of the GHP. Simultaneously, employing a low-thermal-conductivity elastomer helps concentrate heat onto FTD, thereby enhancing thermoelectric power generation efficiency. Additionally, the impact of the shape, size, and height of the protrusion structure at the cold end of the GHP on its efficiency was also investigated. The practical application of FTD on GHP was demonstrated.
To ensure the safe operation of railway tunnels and prevent methane disasters in auxiliary tunnels, this paper focuses on the post-construction closure of an auxiliary tunnel (cross tunnel) in a railway tunnel with methane presence. Computational Fluid Dynamics (CFD) simulations were employed to investigate methane migration and accumulation patterns under different sealing conditions in railway auxiliary tunnels. The optimal auxiliary tunnel end-face closure method was identified. Subsequently, the influences of factors such as tunnel length and methane concentration on the explosion characteristics were analyzed under the optimal closed process conditions. The results show that after methane escapes from the coal seam, it initially accumulates at the tunnel’s roof and then diffuses downward due to the concentration gradient. When the lower end face of the auxiliary tunnel is opened and the upper end face is sealed, the degree of methane enrichment in the tunnel is the lowest and the enrichment speed is the slowest. Under partial methane conditions, the explosion pressure propagated and released more easily within the tunnel, leading to higher peak pressure. As the length of the tunnel increases, the peak pressure of the explosion increases, and the explosion power becomes greater. The overpressure of the explosion shock wave follows a nonlinear relationship with distance and is inversely proportional to the square root of the distance. The findings provide theoretical guidance for the prevention and control of methane-related accidents and disasters.