Kyo Seon Hwang

Prof. Kyo Seon Hwang

Department of Clinical Pharmacology and Therapeutics, College of Medicine, Kyung Hee University, Seoul 02453, Korea
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 August 2021 in Biomedical Engineering Letters
Verified
Journal Article
Closed access
PDF file
JKJae Hyun Kim
Jae Hyun Kim
YSYoung Joon Suh
Young Joon Suh
DPDongsung Park
Dongsung Park
HYHyoju Yim
Hyoju Yim
HKHongrae Kim
Hongrae Kim
Kyo Seon HwangKyo Seon Hwang
Kyo Seon Hwang

1 November 2020 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
DPDongsung Park
Dongsung Park
JKJae Hyun Kim
Jae Hyun Kim
HKHye Jin Kim
Hye Jin Kim
DLDongtak Lee
Dongtak Lee
DLDavid S. Lee
David S. Lee
Kyo Seon HwangKyo Seon Hwang
Kyo Seon Hwang

21 August 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YYYong Kyoung Yoo
Yong Kyoung Yoo
JKJinsik Kim
Jinsik Kim
GKGangeun Kim
Gangeun Kim
YoungSoo KimYoungSoo Kim
YoungSoo Kim
HKHye Yun Kim
Hye Yun Kim
Kyo Seon HwangKyo Seon Hwang
Kyo Seon Hwang
We developed an interdigitated microelectrode (IME) sensor system for blood-based Alzheimer’s disease (AD) diagnosis based on impedimetric detection of amyloid-β (Aβ) protein, which is a representative candidate biomarker for AD. The IME sensing device was fabricated using a surface micromachining process. For highly sensitive detection of several tens to hundreds of picogram/mL of Aβ in blood, medium change from plasma to PBS buffer was utilized with signal cancellation and amplification processing (SCAP) system. The system demonstrated approximately 100-folds higher sensitivity according to the concentrations. A robust antibody-immobilization process was used for stability during medium change. Selectivity of the reaction due to the affinity of Aβ to the antibody and the sensitivity according to the concentration of Aβ were also demonstrated. Considering these basic characteristics of the IME sensor system, the medium change was optimized in relation to the absolute value of impedance change and differentiated impedance changes for real plasma based Aβ detection. Finally, the detection of Aβ levels in transgenic and wild-type mouse plasma samples was accomplished with the designed sensor system and the medium-changing method. The results confirmed the potential of this system to discriminate between patients and healthy controls, which would enable blood-based AD diagnosis.

5 April 2019 in Science Advances
Verified
Journal Article
Open access
PDF file
YoungSoo KimYoungSoo Kim
YoungSoo Kim
YYYong Kyoung Yoo
Yong Kyoung Yoo
JRJee-Hoon Roh
Jee-Hoon Roh
JKJin Sik Kim
Jin Sik Kim
SBSeungyeop Baek
Seungyeop Baek
Kyo Seon HwangKyo Seon Hwang
Kyo Seon Hwang
We compared levels of Aβ by self-standard in plasma using an interdigitated microelectrode sensor to detect Alzheimer disease.

1 February 2018 in Sensors
Verified
Journal Article
Open access
PDF file
JPJin Soo Park
Jin Soo Park
HKHye Jin Kim
Hye Jin Kim
JLJi-Hoon Lee
Ji-Hoon Lee
JPJung Ho Park
Jung Ho Park
JKJin Sik Kim
Jin Sik Kim
BLByung Chul Lee
Byung Chul Lee
Faradaic electrochemical impedance spectroscopy (f-EIS) in the presence of redox reagent, e.g., [Fe(CN)6]3−/4−, is widely used in biosensors owing to its high sensitivity. However, in sensors detecting amyloid beta (Aβ), the redox reagent can cause the aggregation of Aβ, which is a disturbance factor in accurate detection. Here, we propose an interdigitated microelectrode (IME) based f-EIS technique that can alleviate the aggregation of Aβ and achieve high sensitivity by buffer control. The proposed method was verified by analyzing three different EIS-based sensors: non-faradaic EIS (nf-EIS), f-EIS, and the proposed f-EIS with buffer control. We analyzed the equivalent circuits of nf-EIS and f-EIS sensors. The dominant factors of sensitivity were analyzed, and the impedance change rates via Aβ reaction was compared. We measured the sensitivity of the IME sensors based on nf-EIS, f-EIS, and the proposed f-EIS. The results demonstrate that the proposed EIS-based IME sensor can detect Aβ with a sensitivity of 7.40-fold and 10.93-fold higher than the nf-EIS and the f-EIS sensors, respectively.

1 April 2020 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
YYYong Kyoung Yoo
Yong Kyoung Yoo
GKGangeun Kim
Gangeun Kim
DPDongsung Park
Dongsung Park
JKJin Sik Kim
Jin Sik Kim
YoungSoo KimYoungSoo Kim
YoungSoo Kim
Kyo Seon HwangKyo Seon Hwang
Kyo Seon Hwang