Fuzhi Cao

Dr. Fuzhi Cao

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 July 2024 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
KTKangqi Tian
Kangqi Tian
Xu ZhangXu Zhang
Xu Zhang
MSMinxia Shi
Minxia Shi
Jianzhi YangJianzhi Yang
Jianzhi Yang
FCFuzhi Cao
Fuzhi Cao
GLGang Liu
Gang Liu
The MINI-magnetically shielded room (MINI-MSR) offers a near-zero magnetic environment for the high performance of optically pumped atomic magnetometers (OPMs) in magnetoencephalography (MEG) tests. It has the advantages, such as being small-sized, portable, lightweight, offering efficient space utilization, and being cost-effective. However, owing to its small size and narrow internal space, the MINI-MSR can only provide a limited uniform region with larger gradients and irregular magnetic noise distributions. Moreover, it is affected by large external background fluctuations. Once the external interference exceeds the magnetic shielding capacity of the MINI-MSR, the precision of OPMs is compromised. Therefore, an active magnetic compensation system (AMCS) composed of biplanar coils (BCs) is introduced to enlarge the uniform region, maintaining the inhomogeneity errors below 1% to meet the measurement accuracy. However, conventional algorithms for designing BCs struggle with searching for the regularization coefficient ω that determines the coil’s shape. The process lacks ergodicity and efficiency, posing challenges in obtaining maximum volume and uniformity within the target region. In this study, a new hybrid method (NHM) composed of the target field method (TFM), image method (IM), and novel artificial fish swarm algorithm (novel ASFA) is proposed to design BCs for the AMCS. The aim is to suppress background field fluctuations, enhancing the signal-to-noise ratio while addressing coupled errors to reduce larger gradients and magnetic noise levels. Experimental results show that the maximum inhomogeneity error of BCs is less than 1.23%, which is consistent with simulation results. The sensitivity of the AMCS at 0.01 Hz ranges from 180 to 0.16 pT/Hz 1/2 , realizing the noise suppression ratio of 30.51 dB. Based on the closed-loop AMCS, the signal-to-noise ratio in the alpha rhythm generation task is effectively improved.

7 January 2022 in iScience
Verified
Journal Article
Open access
NANan An
Nan An
FCFuzhi Cao
Fuzhi Cao
WLWen Li
Wen Li
WWWenli Wang
Wenli Wang
WXWeinan Xu
Weinan Xu
XNXiaolin Ning
Xiaolin Ning
In recent years, optically pumped magnetometer (OPM)-based magnetoencephalography (MEG) has shown potential for analyzing brain activity. It has a flexible sensor configuration and comparable sensitivity to conventional SQUID-MEG. We constructed a 32-channel OPM-MEG system and used it to measure cortical responses to median and ulnar nerve stimulations. Traditional magnetic source imaging methods tend to blur the spatial extent of sources. Accurate estimation of the spatial size of the source is important for studying the organization of brain somatotopy and for pre-surgical functional mapping. We proposed a new method called variational free energy-based spatial smoothing estimation (FESSE) to enhance the accuracy of mapping somatosensory cortex responses. A series of computer simulations based on the OPM-MEG showed better performance than the three types of competing methods under different levels of signal-to-noise ratios, source patch sizes, and co-registration errors. FESSE was then applied to the source imaging of the OPM-MEG experimental data.

8 November 2024 in Materials
Verified
Journal Article
Open access
PDF file
YLYijin Liu
Yijin Liu
Jianzhi YangJianzhi Yang
Jianzhi Yang
FCFuzhi Cao
Fuzhi Cao
Xu ZhangXu Zhang
Xu Zhang
SZShiqiang Zheng
Shiqiang Zheng
Magnetic-shielding technologies play a crucial role in the field of ultra-sensitive physical measurement, medical imaging, quantum sensing, etc. With the increasing demand for the accuracy of magnetic measurement, the performance requirements of magnetic-shielding devices are also higher, such as the extremely weak magnetic field, gradient, and low-frequency noise. However, the conventional method to improve the shielding performance by adding layers of materials is restricted by complex construction and inherent materials noise. This paper provides a comprehensive review about the enhancement of magnetic shielding in three aspects, including low-noise materials, magnetization control, and active compensation. The generation theorem and theoretical calculation of materials magnetic noise is summarized first, focusing on the development of spinel ferrites, amorphous, and nanocrystalline. Next, the principles and applications of two magnetization control methods, degaussing and magnetic shaking, are introduced. In the review of the active magnetic compensation system, the forward and inverse design methods of coil and the calculation method of the coupling effect under the ferromagnetic boundary of magnetic shield are explained in detail, and their applications, especially in magnetocardiography (MCG) and magnetoencephalogram (MEG), are also mainly described. In conclusion, the unresolved challenges of different enhancement methods in materials preparation, optimization of practical implementation, and future applications are proposed, which provide comprehensive and instructive references for corresponding research.

29 March 2023 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
FCFuzhi Cao
Fuzhi Cao
NANan An
Nan An
WXWeinan Xu
Weinan Xu
WWWenli Wang
Wenli Wang
WLWen Li
Wen Li
XNXiaolin Ning
Xiaolin Ning
The advent of optically pumped magnetometers (OPMs) facilitates the development of on-scalp magnetoencephalography (MEG). In particular, the triaxial OPM emerged recently, making simultaneous measurements of all three orthogonal components of vector fields possible. The detection of triaxial magnetic fields improves the interference suppression capability and achieves higher source localization accuracy using fewer sensors. The source localization accuracy of MEG is based on the accurate co-registration of MEG and MRI. In this study, we proposed a triaxial co-registration method according to combined principal component analysis and iterative closest point algorithms for use of a flexible cap. A reference phantom with known sensor positions and orientations was designed and constructed to evaluate the accuracy of the proposed method. Experiments showed that the average co-registered position errors of all sensors were approximately 1 mm and average orientation errors were less than 2.5° in the X - and Y orientations and less than 1.6° in the Z orientation. Furthermore, we assessed the influence of co-registration errors on the source localization using simulations. The average source localization error of approximately 1 mm reflects the effectiveness of the co-registration method. The proposed co-registration method facilitates future applications of triaxial sensors on flexible caps.

15 September 2022 in Frontiers in Neuroscience
Verified
Journal Article
Open access
FCFuzhi Cao
Fuzhi Cao
NANan An
Nan An
WXWeinan Xu
Weinan Xu
WWWenli Wang
Wenli Wang
WLWen Li
Wen Li
XNXiaolin Ning
Xiaolin Ning
Magnetoencephalography (MEG) based on optically pumped magnetometers (OPM-MEG) has shown better flexibility in sensor configuration compared with the conventional superconducting quantum interference devices-based MEG system while being better suited for all-age groups. However, this flexibility presents challenges for the co-registration of MEG and magnetic resonance imaging (MRI), hindering adoption. This study presents a toolbox called OMMR, developed in Matlab, that facilitates the co-registration step for researchers and clinicians. OMMR integrates the co-registration methods of using the electromagnetic digitization system and two types of optical scanners (the structural-light and laser scanner). As the first open-source co-registration toolbox specifically for OPM-MEG, the toolbox aims to standardize the co-registration process and set the ground for future applications of OPM-MEG.

6 March 2024 in Measurement
Verified
Journal Article
Closed access
WWWenli Wang
Wenli Wang
FCFuzhi Cao
Fuzhi Cao
NANan An
Nan An
LWLi Wen
Li Wen
WXWeinan Xu
Weinan Xu
XNXiaolin Ning
Xiaolin Ning