Nan An

Dr. Nan An


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2022 in iScience
Verified
Journal Article
Open access
NANan An
Nan An
FCFuzhi Cao
Fuzhi Cao
WLWen Li
Wen Li
WWWenli Wang
Wenli Wang
WXWeinan Xu
Weinan Xu
XNXiaolin Ning
Xiaolin Ning
In recent years, optically pumped magnetometer (OPM)-based magnetoencephalography (MEG) has shown potential for analyzing brain activity. It has a flexible sensor configuration and comparable sensitivity to conventional SQUID-MEG. We constructed a 32-channel OPM-MEG system and used it to measure cortical responses to median and ulnar nerve stimulations. Traditional magnetic source imaging methods tend to blur the spatial extent of sources. Accurate estimation of the spatial size of the source is important for studying the organization of brain somatotopy and for pre-surgical functional mapping. We proposed a new method called variational free energy-based spatial smoothing estimation (FESSE) to enhance the accuracy of mapping somatosensory cortex responses. A series of computer simulations based on the OPM-MEG showed better performance than the three types of competing methods under different levels of signal-to-noise ratios, source patch sizes, and co-registration errors. FESSE was then applied to the source imaging of the OPM-MEG experimental data.

29 March 2023 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
FCFuzhi Cao
Fuzhi Cao
NANan An
Nan An
WXWeinan Xu
Weinan Xu
WWWenli Wang
Wenli Wang
WLWen Li
Wen Li
XNXiaolin Ning
Xiaolin Ning
The advent of optically pumped magnetometers (OPMs) facilitates the development of on-scalp magnetoencephalography (MEG). In particular, the triaxial OPM emerged recently, making simultaneous measurements of all three orthogonal components of vector fields possible. The detection of triaxial magnetic fields improves the interference suppression capability and achieves higher source localization accuracy using fewer sensors. The source localization accuracy of MEG is based on the accurate co-registration of MEG and MRI. In this study, we proposed a triaxial co-registration method according to combined principal component analysis and iterative closest point algorithms for use of a flexible cap. A reference phantom with known sensor positions and orientations was designed and constructed to evaluate the accuracy of the proposed method. Experiments showed that the average co-registered position errors of all sensors were approximately 1 mm and average orientation errors were less than 2.5° in the X - and Y orientations and less than 1.6° in the Z orientation. Furthermore, we assessed the influence of co-registration errors on the source localization using simulations. The average source localization error of approximately 1 mm reflects the effectiveness of the co-registration method. The proposed co-registration method facilitates future applications of triaxial sensors on flexible caps.

6 March 2024 in Measurement
Verified
Journal Article
Closed access
WWWenli Wang
Wenli Wang
FCFuzhi Cao
Fuzhi Cao
NANan An
Nan An
LWLi Wen
Li Wen
WXWeinan Xu
Weinan Xu
XNXiaolin Ning
Xiaolin Ning

23 March 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
NANan An
Nan An
FCFuzhi Cao
Fuzhi Cao
WLWen Li
Wen Li
WWWenli Wang
Wenli Wang
WXWeinan Xu
Weinan Xu
XNXiaolin Ning
Xiaolin Ning
Objective: Magnetoencephalography (MEG) is a non-invasive technique that measures the magnetic fields of brain activity. In particular, a new type of optically pumped magnetometer (OPM)-based wearable MEG system has been developed in recent years. Source localization in MEG can provide signals and locations of brain activity. However, conventional source localization methods face the difficulty of accurately estimating multiple sources. The present study presented a new parametric method to estimate the number of sources and localize multiple sources. In addition, we applied the proposed method to a constructed wearable OPM-MEG system. Methods: We used spatial clustering of the dipole spatial distribution to detect sources. The spatial distribution of dipoles was obtained by segmenting the MEG data temporally into slices and then estimating the parameters of the dipoles on each data slice using the particle swarm optimization algorithm. Spatial clustering was performed using the spatial-temporal density-based spatial clustering of applications with a noise algorithm. The performance of our approach for detecting multiple sources was compared with that of four typical benchmark algorithms using the OPM-MEG sensor configuration. Results: The simulation results showed that the proposed method had the best performance for detecting multiple sources. Moreover, the effectiveness of the method was verified by a multimodel sensory stimuli experiment on a real constructed 31-channel OPM-MEG. Conclusion: Our study provides an effective method for the detection of multiple sources. Significance: With the improvement of the source localization methods, MEG may have a wider range of applications in neuroscience and clinical research.

7 November 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
CWChunhui Wang
Chunhui Wang
FCFuzhi Cao
Fuzhi Cao
WWWenli Wang
Wenli Wang
WXWeinan Xu
Weinan Xu
WLWen Li
Wen Li
NANan An
Nan An
Magnetoencephalography (MEG) is a powerful noninvasive neuroimaging technique with high spatiotemporal resolution. Recently, a new generation of MEG, optically pumped magnetometer (OPM)-based wearable MEG, has been developed. Compared to the conventional MEG based on superconducting quantum interference devices with a fixed sensor array, the OPM-MEG is closer to the scalp and is movement-compatible. This provides an excellent opportunity for MEG to expand its further application scenarios, such as virtual reality interactive tasks and the scanning of participants with movement disorders. In this study, we reviewed the hardware composition and performed artifact analysis of wearable OPM-MEGs. The hurdle for the OPM-MEG in achieving movement compatibility is its susceptibility to large head-movement artifacts, which is related to the magnitude and gradient levels of the background magnetic fields. Therefore, we analyzed hardware and software methods to suppress movement artifacts. In addition, we summarize the performed experiments and applications involving the participants’ movements to illustrate the current movement-compatible performance of the OPM-MEG. Finally, we discussed the implications, challenges and future research priorities of improving movement compatibility. This study aims to provide a reference for researchers who attempt to use and apply wearable OPM-MEG in movement-related neuroscience or clinical research.

19 July 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
FCFuzhi Cao
Fuzhi Cao
NANan An
Nan An
WWWenli Wang
Wenli Wang
WXWeinan Xu
Weinan Xu
WLWen Li
Wen Li
XNXiaolin Ning
Xiaolin Ning
Optically pumped magnetometer (OPM)-based magnetoencephalography (MEG) has attracted significant attention due to its flexible sensor configuration and closer proximity to the scalp. The source localization technique of MEG is used in neuroscience and clinical research. Different head models have been developed to provide a forward solution for MEG source localization. However, the effects of different head models have not yet been studied under the new OPM-MEG measurement scenario. In this simulation study, we investigated the effects of eight head models [a local sphere (LS), a corrected sphere (CS), a boundary element method (BEM)-based, and five finite-element method (FEM)-based models, including isotropic three-, four-, and five-compartment and two anisotropic five-compartment head models] for forward and inverse solutions. In addition, we studied the effects of these eight head models in a more realistic environment, such as under sensor coregistration error and measurement noise. The results showed that the source localization error (LE) between the simplified head model and the isotropic five-compartment FEM model can reach 4–5 mm, emphasizing the necessity of using an elaborate head model. In addition, in the comparison of forward and inverse problems, the distinction of cerebrospinal fluid (CSF) showed the most obvious improvement. Thus, an FEM head model with a CSF compartment is recommended. Furthermore, a high level of measurement noise (>80%, the ratio of root mean square of the noise matrix to the data matrix) and high coregistration errors (rotation error > 2°) significantly reduced the contributions of realistic head models.