Background: 4D Flow MRI is a quantitative imaging technique to evaluate blood flow patterns; however, it is unclear how compressed sensing (CS) acceleration would impact aortic hemodynamic quantification in type B aortic dissection (TBAD).Purpose: To investigate CS‐accelerated 4D Flow MRI performance compared to GRAPP‐accelerated 4D Flow MRI (GRAPPA) to evaluate aortic hemodynamics in TBAD.Study Type: Prospective.Population: Twelve TBAD patients, two volunteers.Field Strength/Sequence: 1.5T, 3D time‐resolved cine phase‐contrast gradient echo sequence.Assessment: GRAPPA (acceleration factor [R] = 2) and two CS‐accelerated (R = 7.7 [CS7.7] and 10.2 [CS10.2]) 4D Flow MRI scans were acquired twice for interscan reproducibility assessment. Voxelwise kinetic energy (KE), peak velocity (PV), forward flow (FF), reverse flow (RF), and stasis were calculated. Plane‐based mid‐lumen flows were quantified. Imaging times were recorded.Tests: Repeated measures analysis of variance, Pearson correlation coefficients (r), intraclass correlation coefficients (ICC). P < 0.05 indicated statistical significance.Results: The KE and FF in true lumen (TL) and PV in false lumen (FL) did not show difference among three acquisition types (P = 0.818, 0.065, 0.284 respectively). The PV and stasis in TL were higher, KE, FF, and RF in FL were lower, and stasis was higher in GRAPPA compared to CS7.7 and CS10.2. The RF was lower in GRAPPA compared to CS10.2. The correlation coefficients were strong in TL (r = [0.781–0.986]), and low to strong in FL (r = [0.347–0.948]). The ICC levels demonstrated moderate to excellent interscan reproducibility (0.732–0.989). The FF and net flow in mid‐descending aorta TL were significantly different between CS7.7 and CS10.2.Conclusion: CS‐accelerated 4D Flow MRI has potential for clinical utilization with shorter scan times in TBAD. Our results suggest similar hemodynamic trends between acceleration types, but CS‐acceleration impacts KE, FF, RF, and stasis more in FL.Evidence Level: 1Technical Efficacy: Stage 2
Epilepsy is a disease known to occur with autonomous phenomenons. Earlier studies indicate decreased heart rate variability (HRV) during ictal and interictal periods among epilepsy patients. In this study, we aim to investigate cardiac rhythm abnormalities and HRV during interictal period between drug-naïve patients with idiopathic generalized epilepsy (IGE) and healthy control group. Twenty-six patients with IGE and 26 healthy individuals included in the study. In order to eliminate any structural cardiac pathology, transthoracic echocardiography was performed in all subjects and time and frequency domain parameters of HRV were evaluated after 24-hour rhythm holter monitoring. Between two groups, no significant difference was detected in terms of mean heart rate and maximum duration between the start of the Q waves and the end of the T waves (QT intervals). In the time domain analysis of HRV, no statically significant difference was detected for standard deviation of all R - R intervals and root-mean-square of successive differences between patient and control group (p = 0,070 and p = 0,104 respectively). In the frequency domain analysis of HRV, patients tended to display lower total power and very low frequency power than did healthy subjects, but the differences were not statistically significant. Our results suggest that there is no major effect of the epilepsy on HRV in patients with IGE. It should be emphasized that, in this study, HRV was evaluated only in patients with IGE and that the results are not proper to be generalized for patients with partial seizures.