Wuyun Xiao

Dr. Wuyun Xiao

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2021 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
YCYe Chen
Ye Chen
JLJinglun Li
Jinglun Li
YZYuzhong Zhang
Yuzhong Zhang
WXWuyun Xiao
Wuyun Xiao

14 April 2023 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
CLChongwei Li
Chongwei Li
HZHongzhao Zhou
Hongzhao Zhou
HLHaixia Liu
Haixia Liu
TSTao Sun
Tao Sun
HFHaijun Fan
Haijun Fan
WXWuyun Xiao
Wuyun Xiao

9 December 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
HZHong-Zhao Zhou
Hong-Zhao Zhou
WXWuyun Xiao
Wuyun Xiao
HLHaixia Liu
Haixia Liu
TSTao Sun
Tao Sun
CLChongwei Li
Chongwei Li
LLLufeng Liu
Lufeng Liu

6 May 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
JXJianming Xie
Jianming Xie
YCYe Chen
Ye Chen
SQSheng Qi
Sheng Qi
Wenzhuo ChenWenzhuo Chen
Wenzhuo Chen
YLYang Liu
Yang Liu
WXWuyun Xiao
Wuyun Xiao

26 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JXJianming Xie
Jianming Xie
LYliu Yang
liu Yang
JLJinglun Li
Jinglun Li
SQSheng Qi
Sheng Qi
WCWenzhuo Chen
Wenzhuo Chen
WXWuyun Xiao
Wuyun Xiao
To overcome the temperature effect of NaI(Tl) detectors for energy spectrometry without additional hardware, a new correction method was put forward based on pulse deconvolution, trapezoidal shaping and amplitude correction, named DTSAC. To verify this method, actual pulses from a NaI(Tl)-PMT detector were measured at various temperatures from −20 °C to 50 °C. Pulse processing and spectrum synthesis showed that the position drift of the 137Cs 662 keV peak was less than 3 keV, and the corresponding resolution at 662 keV of the sum spectra ranged from 6.91% to 10.60% with the trapezoidal width set from 1000 ns to 100 ns. The DTSAC method corrects the temperature effect via pulse processing, and needs no reference peak, reference spectrum or additional circuits. The method solves the problem of correction of pulse shape and pulse amplitude at the same time, and can be used even at a high counting rate.

27 April 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
JXJianming Xie
Jianming Xie
LYliu Yang
liu Yang
JLJinglun Li
Jinglun Li
YZYuzhong Zhang
Yuzhong Zhang
SQSheng Qi
Sheng Qi
WXWuyun Xiao
Wuyun Xiao
To overcome the temperature effect of NaI(Tl) detectors for energy spectrometry without additional hardware, a new correction method was put forward based on pulse deconvolution, trapezoidal shaping and amplitude correction, named DTSAC. To verify this method, actual pulses from a NaI(Tl)-PMT detector were measured at different temperatures from -20℃ to 50℃. Pulse processing and spectrum synthesis showed that the position drift of the 662 keV peak was less than 3 keV, and the corresponding resolution at 662 keV of the sum spectra ranges from 6.9% to 10.60% with trapezoidal width set as 1000 ns to 100 ns. The DTSAC method corrects temperature effect by pulse processing, and need no reference peak, reference spectrum and additional circuits. The method solves the problem of correction of pulse shape and pulse amplitude at the same time, and can be used even at high counting rate.