To overcome the temperature effect of NaI(Tl) detectors for energy spectrometry without additional hardware, a new correction method was put forward based on pulse deconvolution, trapezoidal shaping and amplitude correction, named DTSAC. To verify this method, actual pulses from a NaI(Tl)-PMT detector were measured at various temperatures from −20 °C to 50 °C. Pulse processing and spectrum synthesis showed that the position drift of the 137Cs 662 keV peak was less than 3 keV, and the corresponding resolution at 662 keV of the sum spectra ranged from 6.91% to 10.60% with the trapezoidal width set from 1000 ns to 100 ns. The DTSAC method corrects the temperature effect via pulse processing, and needs no reference peak, reference spectrum or additional circuits. The method solves the problem of correction of pulse shape and pulse amplitude at the same time, and can be used even at a high counting rate.

27 April 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
JXJianming Xie
Jianming Xie
LYliu Yang
liu Yang
JLJinglun Li
Jinglun Li
YZYuzhong Zhang
Yuzhong Zhang
SQSheng Qi
Sheng Qi
WXWuyun Xiao
Wuyun Xiao
To overcome the temperature effect of NaI(Tl) detectors for energy spectrometry without additional hardware, a new correction method was put forward based on pulse deconvolution, trapezoidal shaping and amplitude correction, named DTSAC. To verify this method, actual pulses from a NaI(Tl)-PMT detector were measured at different temperatures from -20℃ to 50℃. Pulse processing and spectrum synthesis showed that the position drift of the 662 keV peak was less than 3 keV, and the corresponding resolution at 662 keV of the sum spectra ranges from 6.9% to 10.60% with trapezoidal width set as 1000 ns to 100 ns. The DTSAC method corrects temperature effect by pulse processing, and need no reference peak, reference spectrum and additional circuits. The method solves the problem of correction of pulse shape and pulse amplitude at the same time, and can be used even at high counting rate.

9 October 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
JZJipeng Zhang
Jipeng Zhang
XXXiong Xiao
Xiong Xiao
YCYe Chen
Ye Chen
BZBin Zhang
Bin Zhang
XMXinhua Ma
Xinhua Ma
JLJinglun Li
Jinglun Li
(1) Background: The imaging energy range of a typical Compton camera is limited due to the fact that scattered gamma photons are seldom fully absorbed when the incident energies are above 3 MeV. Further improving the upper energy limit of gamma-ray imaging has important application significance in active interrogation of special nuclear materials and chemical warfare agents, as well as range verification of proton therapy; (2) Methods: To realize gamma-ray imag-ing in a wide energy range of 0.3~7 MeV, a principle prototype, named a portable three-layer Compton camera, was developed using the scintillation detector that consist of an silicon photo-multiplier array coupled with a Gd3Al2Ga3O12:Ce pixelated scintillator array. Implemented in a list-mode maximum likelihood expectation maximization algorithm, a far-field energy-domain imaging method based on two-interaction and three-interaction events was applied to estimate the initial energy and spatial distribution of gamma-ray sources. The simulation model of detec-tors was established based on Monte Carlo simulation toolkit Geant4. The reconstructed images of a 133Ba, a 137Cs and a 60Co point-like sources were successfully obtained with our prototype in laboratory tests and compared with simulation studies; (3) Results: The proportion of effective imaging events accounted for about 2%, which made our prototype realize reconstructing the distribution of a 0.05 μSv/h 137Cs source in 10 seconds. The angular resolution for resolving two 137Cs point-like sources was 15°. Additional simulated imaging of the 6.13 MeV gamma-rays from 14.1 MeV neutron scattering with water preliminarily demonstrated the imaging capability for high incident energy; (4) Conclusions: We concluded that the prototype had good imaging per-formance in a wide energy range (0.3~7 MeV), which showed potential in several MeV gam-ma-ray imaging applications.