Emma Farago

Emma Farago


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 April 2022 in IEEE Reviews in Biomedical Engineering
Verified
Journal Article
Closed access
EFEmma Farago
Emma Farago
DMDawn MacIsaac
Dawn MacIsaac
MSMichelle Suk
Michelle Suk
ACAdrian Chan
Adrian Chan
Electromyography (EMG) signals are instrumental in a variety of applications including prosthetic control, muscle health assessment, rehabilitation, and workplace monitoring. Signal contaminants including noise, interference, and artifacts can degrade the quality of the EMG signal, leading to misinterpretation; therefore it is important to ensure that collected EMG signals are of sufficient quality prior to further analysis. A literature search was conducted to identify current approaches for detecting, identifying, and quantifying contaminants within surface EMG signals. We identified two main strategies: 1) bottom-up approaches for identifying specific and well-characterized contaminants and 2) top-down approaches for detecting anomalous EMG signals or outlier channels in high-density EMG arrays. The best type(s) of approaches are dependent on the circumstances of data collection including the environment, the susceptibility of the application to contaminants, and the resilience of the application to contaminants. Further research is needed for assessing EMG with multiple simultaneous contaminants, identifying ground-truths for clean EMG data, and developing user-friendly and autonomous methods for EMG signal quality analysis.

15 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
EFEmma Farago
Emma Farago
ACAdrian Chan
Adrian Chan
High-density electromyography (HD-EMG) arrays allow for the study of muscle activity in both time and space by recording electrical potentials produced by muscle contractions. HD-EMG array measurements are susceptible to noise and artifacts and frequently contain some poor-quality channels. This paper proposes an interpolation-based method for the detection and reconstruction of poor-quality channels in HD-EMG arrays. The proposed detection method identified artificially contaminated channels of HD-EMG for signal-to-noise ratio (SNR) levels 0 dB and lower with ≥99.9% precision and ≥97.6% recall. The interpolation-based detection method had the best overall performance compared with two other rule-based methods that used the root mean square (RMS) and normalized mutual information (NMI) to detect poor-quality channels in HD-EMG data. Unlike other detection methods, the interpolation-based method evaluated channel quality in a localized context in the HD-EMG array. For a single poor-quality channel with an SNR of 0 dB, the F1 scores for the interpolation-based, RMS, and NMI methods were 99.1%, 39.7%, and 75.9%, respectively. The interpolation-based method was also the most effective detection method for identifying poor channels in samples of real HD-EMG data. F1 scores for the detection of poor-quality channels in real data for the interpolation-based, RMS, and NMI methods were 96.4%, 64.5%, and 50.0%, respectively. Following the detection of poor-quality channels, 2D spline interpolation was used to successfully reconstruct these channels. Reconstruction of known target channels had a percent residual difference (PRD) of 15.5 ± 12.1%. The proposed interpolation-based method is an effective approach for the detection and reconstruction of poor-quality channels in HD-EMG.

17 October 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
EFEmma Farago
Emma Farago
ACAdrian Chan
Adrian Chan
Adequate electromyography (EMG) signal quality is important for obtaining correct interpretations for EMG diagnostics and EMG-based control. In this pilot study, a dataset (N = 2) of high-density recordings of the biceps and triceps was rated on a four-point scale by two expert EMG raters. The intra-rater reliability was good-to-excellent (ICC (2,1) > 0.76) and the inter-rater reliability was good (ICC (3,k) = 0.85). Four regression models were developed to label electrodes automatically: 1) linear regression, 2) random forest regression, 3) support vector regression, and 4) a combination of the models obtained via majority voting. Using the human raters as a ground truth, the random forest and support vector regression obtained a very strong correlation (r s = 0.90) and excellent reliability (ICC (3,k) = 0.95). These results demonstrate the potential for the development of an automated process to quantify EMG channel quality.