5 April 2022 in IEEE Reviews in Biomedical Engineering
Verified
Journal Article
Closed access
EFEmma Farago
Emma Farago
DMDawn MacIsaac
Dawn MacIsaac
MSMichelle Suk
Michelle Suk
ACAdrian Chan
Adrian Chan
Electromyography (EMG) signals are instrumental in a variety of applications including prosthetic control, muscle health assessment, rehabilitation, and workplace monitoring. Signal contaminants including noise, interference, and artifacts can degrade the quality of the EMG signal, leading to misinterpretation; therefore it is important to ensure that collected EMG signals are of sufficient quality prior to further analysis. A literature search was conducted to identify current approaches for detecting, identifying, and quantifying contaminants within surface EMG signals. We identified two main strategies: 1) bottom-up approaches for identifying specific and well-characterized contaminants and 2) top-down approaches for detecting anomalous EMG signals or outlier channels in high-density EMG arrays. The best type(s) of approaches are dependent on the circumstances of data collection including the environment, the susceptibility of the application to contaminants, and the resilience of the application to contaminants. Further research is needed for assessing EMG with multiple simultaneous contaminants, identifying ground-truths for clean EMG data, and developing user-friendly and autonomous methods for EMG signal quality analysis.

20 March 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
BTBahareh Taji
Bahareh Taji
ACAdrian Chan
Adrian Chan
SSShervin Shirmohammadi
Shervin Shirmohammadi
Objective: This paper investigates the effect of applied pressure on the skin-electrode impedance. Applied pressure, which affects the skin-electrode impedance, can fluctuate in many acquisition setups, particularly in wearable devices. The skin-electrode impedance, in turn, impacts the quality of the recorded signal in biomedical monitoring devices. Methods: Three types of electrodes were examined: Ag/AgCl electrodes, conductive textile electrodes, and dry electrodes with surface microfeatures (Orbital Research Inc.). Impedance measurements were conducted as pressure was repeatedly applied (P = 4 kPa) and removed (P = 0 kPa) over several trials. A Cole-Cole impedance model was utilized to model the skin-electrode interface. Significance and Results: Results demonstrated large decreases in the skin-electrode impedance of dry electrodes (conductive textile and orbital electrodes), especially with the initial application of the pressure. Model parameters also proved to be highly dependent on the level of pressure in dry electrodes but less dependent and more stable in wet electrodes. Decreases in skin-electrode impedance associated with applied pressure were thought to be caused by an increased effective electrode contact area. Changes in skin-electrode impedance were irreversible, lasting even after the applied pressure was released. Differences skin-electrode impedance associated with changes in applied pressure, decreased as the number of trials increased. Conclusion: Applied pressure has larger effect on dry electrodes than wet electrodes. Wearable devices that employ dry electrodes may have poorer biomedical signal quality when initially donned; however, the advantage of wet electrodes with their lower sensitivity to applied pressure is diminished in long-term monitoring applications.

28 November 2017 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
BTBahareh Taji
Bahareh Taji
ACAdrian Chan
Adrian Chan
SSShervin Shirmohammadi
Shervin Shirmohammadi
We propose and validate a novel method to reduce the false alarm (FA) rate caused by poor-quality electrocardiogram (ECG) signal measurement during atrial fibrillation (AFib) detection. A deep belief network is used to differentiate acceptable from unacceptable ECG segments. To validate the method, eight different levels of ECG quality are provided by artificially contaminating ECG records, from the MIT-BIH AFib database, with motion artifact from the MIT-BIH noise stress test database. ECG segments classified as ``unacceptable,'' in terms of signal quality, are restricted from AFib detection process. Results are evaluated for each level of quality and compared to AFib detection algorithm performance when ECGs of each level of quality are applied to it without performing any classification. Our results show that AFib detection performance for ECG with high signal-to-noise ratio (SNR) is minimally affected by this FA reduction approach. For clean ECG (no added noise), the AFib detection accuracy was 87%, without and with FA reduction. For ECG, with an SNR of -20 dB, the performance of AFib detection is markedly decreased with an accuracy of 58.7%; however, with FA reduction (using our method) the accuracy was increased to 81%.

1 January 2012 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
CKCynthia Kendell
Cynthia Kendell
Edward LemaireEdward Lemaire
Edward Lemaire
YLYves Losier
Yves Losier
AWAdam Wilson
Adam Wilson
ACAdrian Chan
Adrian Chan
BHBernie Hudgins
Bernie Hudgins
A 3×4 electrode array was placed over each of seven muscles and surface electromyography (sEMG) data were collected during isometric contractions. For each array, nine bipolar electrode pairs were formed off-line and sEMG parameters were calculated and evaluated based on repeatability across trials and comparison to an anatomically placed electrode pair. The use of time-domain parameters for the selection of an electrode pair from within a grid-like array may improve upon existing electrode placement methodologies.

1 October 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MAMohamed Abdelazez
Mohamed Abdelazez
SRSreeraman Rajan
Sreeraman Rajan
ACAdrian Chan
Adrian Chan
Atrial Fibrillation (AF) is a serious cardiovascular condition that can lead to complications, including but not limited to stroke, heart attack, and death. AF can be diagnosed using an electrocardiogram (ECG); however, continuous monitoring produces a large amount of data that can increase storage, power, and transmission bandwidth requirements. Compressive sensing has been used to mitigate increased requirements of continuous monitoring. An AF detector using a deterministic compressively sensed ECG is proposed. By detecting AF in the compressed domain, the computationally expensive process of reconstructing the ECG can be avoided. The detector was based on a random forest trained on features extracted using the wavelet transform, empirical mode decomposition, discrete cosine transform, and statistical methods. ECG data from the Long-Term Atrial Fibrillation Database available on Physionet were used. The performances of the detectors trained using features from compressed and uncompressed ECG were compared. Using the trained detector, the area under the receiver operating curve (AUC) and the weighted average precision (AP) were both 0.93 for uncompressed data using record-based 10-fold cross-validation. The AUC and AP were 0.91 and 0.90 at 50% compression, 0.92 and 0.91 at 75% compression, and 0.82 and 0.91 at 95% compression, respectively.

1 January 2006
Verified
Conference Paper
Closed access
ACAdrian Chan
Adrian Chan
MHMohyledin M. Hamdy
Mohyledin M. Hamdy
ABArmin Badre
Armin Badre
VBVesal Badee
Vesal Badee
In this paper, we demonstrate that the electrocardiogram (ECG) can be used as a biometric. While previous studies have shown the potential of an ECG biometric, this research demonstrates it under conditions that include intra-individual variations and a simple user interface, consisting of electrodes held on the pads of the subject's thumbs. ECG person identification was accomplished through quantitative comparisons of an unknown signal to enrolled signals. The quantitative comparisons were: the correlation coefficient and a wavelet distance measure. It was found that the combination of these two methods provided improved performance, relative to either individual method. ECG person identification accuracy was 90.8%. While this accuracy is relatively low compared to conventional biometrics, such as fingerprints, the ECG can be used as supplementary information for a multi-modal biometric system. A multi-modal system that includes the ECG would have increased accuracy and robustness, without necessarily requiring any change to the perceived user interface. At minimum, the ECG would be useful in providing liveness detection