This article presents the cracking and load-bearing behaviour of carbon-reinforced prismatic concrete tensile specimens. Grids with different geometries and impregnations were used as carbon reinforcement. In addition, the roving surfaces were partially coated with a fine sand to improve the bond between concrete and reinforcement. The article shows the influence of the different parameters on the developing cracks with respect to their width and spacing from each other. The material properties and tensile strengths of carbon concrete are also presented. These can be used for calculations. A fine-grained, commercially available shotcrete was used for the investigations. Based on the tests and results described in this article, an influence of the sanded carbon grids on the crack properties (crack widths, crack spacing) could be shown in comparison to unsanded carbon grids.
Carbon fiber reinforced plastics are increasingly used in all areas of industry. With the increasing number of components and semi-finished products, more and more new carbon fibers will be produced. This also generates a greater number of end-of-life components. These end-of-life components can currently only be fed back, to a limited extent, for reuse, thus leading to a non-optimal, closed-material cycle of the carbon fiber. This article provides an overview of the recycling of carbon components, their further processing and their reuse in reinforcement elements made of carbon fibers. In addition, first results from recycled single fibers and yarn tensile tests from recycled carbon fibers (rCF) are presented. By demonstrating the reuse of carbon fibers in the construction sector, there is the potential to effectively close the carbon cycle. The utilization of carbon reinforcements also enables the reduction of concrete consumption, as the minimum concrete cover required to protect the reinforcement from corrosion is no longer needed.
The use of non-metallic reinforcement can significantly reduce the carbon footprint of the construction sector. Mixed structures made out of steel and non-metallic reinforcement should be avoided due to the risk of galvanic corrosion. So far, researchers have been focusing on the load-bearing behavior in the longitudinal direction of the fibers. In this study, the behavior of the fibers in the non-metallic reinforcements is analyzed perpendicular to the fiber orientation. Therefore, a uniaxial shear test on a single bar (uniaxial shear test), as well as a series of push-off tests with reinforcements embedded in the concrete, was carried out. For both experiments, bars made of carbon fiber-reinforced polymers (CFRPs) and glass fiber-reinforced polymers (GFRPs) were investigated. In order to analyze the influence of non-metallic reinforcement in the joint, specimens without reinforcement have been tested as well. Also, the joint roughness and reinforcement ratio of the concrete joint was varied in the tests. The determined transverse shear strengths for the single bar exceed the values of the producer. For the push-off test, high standard deviations occurred, making it difficult to draw firm conclusions. Nevertheless, it is shown that increasing the amount of reinforcement leads to higher ultimate forces. The presented study emphasizes the necessity of further studies of the shear transfer in concrete joints.