Liangliang Song

Mr. Liangliang Song


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2020 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
FPFubin Pang
Fubin Pang
QHQiang Huang
Qiang Huang
YLYu Liu
Yu Liu
PLPeng Li
Peng Li
XKXiangping Kong
Xiangping Kong
LSLiangliang Song
Liangliang Song
The fiber optical current transformer (FOCT) with sine wave modulation has been widely used in the DC transmission project, while its fault rate is much higher than that of an electromagnetic current transformer, which seriously threatens the safe operation of power grid. In order to investigate the fault mechanism of FOCT, the output signal model of the FOCT photodetector is established, and its basic methods of modulation and demodulation are analyzed to explore the influencing factors of the signal processing method used in the calculation of measured current. It is found that the reduction of the second harmonic component in the photodetector output is the root cause of FOCT fault, and the optical path, modulation signal amplitude, and measured current are important factors affecting the second harmonic component. The influencing law of three factors on the second harmonic component is calculated by simulation and the characteristic differences between them are given. Finally, the fault simulation test of FOCT light intensity and a modulation circuit were carried out in the laboratory, and the results verify the correctness of theoretical analysis. The research in this paper provides reference for fault analysis and reliability improvement of FOCT.

12 September 2024 in IEEE Access
Verified
Journal Article
Open access
LSLiangliang Song
Liangliang Song
XHXiang Huang
Xiang Huang
SZShuyi Zhuang
Shuyi Zhuang
ASAodong Shen
Aodong Shen
PXPeidong Xu
Peidong Xu
Table Structure Recognition (TSR) is pivotal in document analysis, especially in end-toend automated identification, which profoundly impacts decision-making and efficiency spanning diverse fields such as power industry, education, healthcare, and scientific papers. However, accurately identifying table structures remains challenging due to complex layouts and irregular distortions. Considering the complex structure of tables in power relay protection systems, this study proposes a novel end-to-end TSR model, leveraging deep learning and innovative modules to address these challenges. Specifically, the new model TSR-Net replaces YOLOv8's backbone with our proposed DSConv-Variants, improving accuracy and reducing parameters. Additionally, a Multi-Scale Attention Module (MAM) captures semantic features efficiently, while a Dynamic Calibration Module (DCM) enhances cross-layer fusion. Experimental results demonstrate the superior performance of our approach on public benchmarks, showcasing its utility for TSR.

10 June 2026 in Energies
Verified
Journal Article
Open access
PDF file
PCPeng Chang
Peng Chang
LSLiangliang Song
Liangliang Song
ZZZhaokun Zhou
Zhaokun Zhou
XZXinrui Zuo
Xinrui Zuo
HWHanli Weng
Hanli Weng
ZLZhenxing Li
Zhenxing Li
Power system parameters are susceptible to multiple influencing factors such as environmental conditions and load current, with line parameters being notably affected. This compromises the accuracy of power flow calculation and fault analysis, and can significantly undermine the reliability of protection schemes. To address these limitations, this study proposes an integrated correction method for power system line parameters via a framework that combines soil resistivity inversion and multi-factor sag calculation. First, based on fault-recording data from external line faults, sequence impedance parameters are calculated using a two-terminal impedance difference subtraction strategy, followed by the inversion of soil resistivity along the transmission corridor. Second, considering the spatial inhomogeneity of the transmission corridor, a sliding-window statistical method is applied to segment the line, and a piecewise series model is employed to correct the zero-sequence impedance parameter. Finally, a conductor temperature and sag model based on the heat balance equation is established. By coupling ambient temperature, wind speed, solar radiation, and mechanical load, the ground capacitance and susceptance parameters are dynamically corrected. Simulation results demonstrate that the proposed framework can systematically achieve dynamic correction of power system line parameters and significantly reduce calculation errors. The developed method provides an effective technical pathway for enhancing the accuracy of power system simulation and improving the reliability of protection schemes.

19 November 2022
Verified
Book Chapter
Closed access
PDF file
YYYi Yang
Yi Yang
LSLiangliang Song
Liangliang Song
SZShuyi Zhuang
Shuyi Zhuang
SCShi Chen
Shi Chen
JLJuan Li
Juan Li