Several cases of abnormal maloperation of the transformer differential protection with second harmonic blocking scheme are reported, which occurs when a type of nonlinear load, such as furnace, is switched-in to the transformer involved power systems. Different from well-known maloperation due to unloaded transformer energization, this type of maloperation does not occur on the time of load switching-in, but with a considerable time delay. The previous theories, including that interpreting sympathetic inrush, cannot be utilized directly to analyze this phenomenon. In this paper, a model for analyzing the transient course of the nonlinear load switching in, together with the description of the simplified characteristics of the transformer core and the nonlinear load is proposed to explain above-mentioned category of mal-operations. A set of nonlinear differential equations are formed using this model and a 4-order Runge-Kutta algorithm is utilized to solve the flux linkages and currents. The waveform and harmonic characteristic of the differential current are analyzed. It is disclosed that the maloperation of the transformer differential protection during the nonlinear load switching in mainly results from the saturation of transformer core caused by the interaction of the two nonlinear elements. This point of view is verified with the simulation tests.
13 October 2023 in IEEE Transactions on Power Systems
Out-of-step (OOS) oscillation is a key link in the power system outage evolution. Precise islanding control can prevent system outages. Renewable energy is connected to the power grid through transverter. From a system construction perspective, it can be regarded as grid-following sources. A large number of inverters lead to more dynamic instability characteristics in the power system, affecting the reliability of existing island control. In this article, the model of oscillation in system with renewable energy is simplified based on the control objective of the converter. The change in OOS oscillation characteristics is analyzed, caused by energy fluctuations. The results show that energy fluctuations during OOS oscillations may affect rotor angle stability and cause the center of oscillation to migrate dynamically over a wide range. This article proposes an islanding control method based on power flow. It only requires dispatchers to obtain power flow information to accurately predict the trend of system instability and dynamically track the center of oscillation. The judgment results can serve as criteria for dealing with the problem of when and where to split the power system. The proposed method has been tested on the IEEE testing system.
18 November 2024 in IEEE Transactions on Industrial Informatics
Accurately assessing power systems’ ability to accommodate wind power is an important basis for systems to participate in the day-ahead wind power market and make reasonable trading plans. However, existing assessment methods do not consider frequency security of systems, which leads to frequency security issues during the execution process of trading results. This paper proposes an assessment method for day-ahead wind power admissibility (DWPA) of power systems considering frequency constraints (FCs). First, a FCs model is established through the oscillation equation of frequency deviation dynamics after system disturbances, and embedded in the assessment of day-ahead DWPA. Then, a robust feasible region definition for wind power output is proposed, and a system operation risk model is developed based on it. Finally, based on the two-stage robust optimization theory, an overall assessment model for the DWPA of power systems considering FCs is proposed, and the column-and-constraint generation algorithm is used to solve the problem. The effectiveness of the proposed method was verified through simulations conducted on the IEEE 9-bus and 118-bus power systems. The results emphasized the importance of taking FCs into account and the enthusiasm of wind farms to provide virtual inertia.
14 June 2021 in IEEE Transactions on Power Delivery
Converter transformers are one of the most important and costly equipment in High Voltage Direct Current (HVDC) transmission systems. They require sensitive and reliable protections. However, the maloperation of restricted earth fault (REF) protection of converter transformers caused by unloaded energization of converter transformers has been reported. Aiming at this problem, the saturation and measurement distortion of the current transformer on neutral line (CTN) and the resulting maloperation mechanism of REF protection are analyzed firstly. Then, an auxiliary restraint scheme of REF protection of converter transformers is proposed exploiting the similarity between the waveforms of the zero-sequence current on neutral line and the calculated zero-sequence current from measured phase currents under magnetizing inrush and fault conditions. The proposed auxiliary restraint scheme is based on normalized dynamic time warping distance (DTWD), which has strong robustness against CT saturation. The proposed auxiliary restraint scheme is verified by simulations and practical data recorded on-site.
3 October 2018 in IEEJ Transactions on Electrical and Electronic Engineering
Aiming at the abnormal operations of converter bridge differential protection of high voltage direct current(HVDC) transmission project, the operation behavior simulation of converter bridge differential protection under various fault conditions is carried out and the reason of the abnormal operations of converter bridge differential protection are explained and analyzed on the basis of PSCAD/EMTDC model. The simulation results indicate that, the converter bridge differential protection can operate correctly when a fault current difference exists between the sampled values of current trans formers (CTs) on the A bridge and Y bridge of the valve side. If the fault current flows or does not flows simultaneously into the CTs on the A bridge and Y bridge of the valve side, the refusal-operation of converter bridge differential protection will occur.