Purpose To develop quantitative dual-tuned (DT) 1H/23Na MRI of human knee cartilage in vivo at 7 Tesla (T). Materials and Methods A sensitive 23Na transceiver array RF coil was developed at 7T. B1 fields generated by the transceiver array coil were characterized and corrected in the 23Na images. Point spread function (PSF) of the 23Na images was measured, and the signal decrease due to partial-volume-effect was compensated in [23Na] quantification of knee cartilage. SNR and [23Na] in anterior femoral cartilage were measured from seven healthy subjects. Results SNR of 23Na image with the transceiver array coil was higher than that of birdcage coil. SNR in the cartilage at 2-mm isotropic resolution was 26.80 ± 3.69 (n = 7). B1 transmission and reception fields produced by the DT coil at 7T were similar to each other. Effective full-width-half-maximum of 23Na image was ∼5 mm at 2-mm resolution. Mean [23Na] was 288.13 ± 29.50 mM (n = 7) in the anterior femoral cartilage of normal subjects. Conclusion We developed a new high-sensitivity 23Na RF coil for knee MRI at 7T. Our 1H/23Na MRI allowed quantitative measurement of [23Na] in knee cartilage by measuring PSF and cartilage thickness from 23Na and 1H image, respectively. J. Magn. Reson. Imaging 2013;38:1063–1072.
Intracortical microstimulation (ICMS) is a method for restoring sensation to people with paralysis as part of a bidirectional brain–computer interface (BCI) to restore upper limb function. Evoking tactile sensations of the hand through ICMS requires precise targeting of implanted electrodes. Here we describe the presurgical imaging procedures used to generate functional maps of the hand area of the somatosensory cortex and subsequent planning that guided the implantation of intracortical microelectrode arrays. In five participants with cervical spinal cord injury, across two study locations, this procedure successfully enabled ICMS‐evoked sensations localized to at least the first four digits of the hand. The imaging and planning procedures developed through this clinical trial provide a roadmap for other BCI studies to ensure the successful placement of stimulation electrodes.
This review article gives an overview of the current state of the art of bladder cancer imaging and then discusses in depth the scientific and technical merit of a novel imaging approach, tracing its evolution from murine cancer models to cancer patients. While the poor resolution of soft tissue obtained by widely available imaging options such as abdominal sonography and radiation-based CT leaves them only suitable for measuring the gross tumor volume and bladder wall thickening, dynamic contrast-enhanced magnetic resolution imaging (DCE MRI) is demonstrably superior in resolving muscle invasion. However, major barriers still exist in its adoption. Instead of injection for DCE-MRI, intravesical contrast-enhanced MRI (ICE-MRI) instills Gadolinium chelate (Gadobutrol) together with trace amounts of superparamagnetic agents for measurement of tumor volume, depth, and aggressiveness. ICE-MRI leverages leaky tight junctions to accelerate passive paracellular diffusion of Gadobutrol (604.71 Daltons) by treading the paracellular ingress pathway of fluorescein sodium and of mitomycin (<400 Daltons) into bladder tumor. The soaring cost of diagnosis and care of bladder cancer could be mitigated by reducing the use of expensive operating room resources with a potential non-surgical imaging option for cancer surveillance, thereby reducing over-diagnosis and over-treatment and increasing organ preservation.