Locally applied vancomycin is increasingly being used in primary hip and knee arthroplasty to reduce the risk of infection. Despite encouraging initial results, considerable debate remains on the basis of the data currently available. In particular, it has been unclear up to now whether local vancomycin is suitable to further reduce the risk of infection even if the rate of infection is already low (< 1%). In this monocentric retrospective cohort study, all primary total hip and knee arthroplasties performed between 2013 and 2018 were included. After a change in procedure at the hospital, 1 g vancomycin powder was applied intraarticularly before wound closure. The remaining perioperative procedure was constant over the investigation period. The follow-up was one year. The presence of an infection according to the currently valid MSIS criteria was defined as the endpoint. In patients with TKA two infections (0.3%) were observed under vancomycin prophylaxis in contrast to 44 infections (1.3%) in the control group (p = 0.033). In patients with THA two infections (0.5%) were observed under vancomycin prophylaxis and 48 infections (1.1%) in the control group without local vancomycin but this difference was statistically not significant. No wound complications requiring revision were observed as a result of the vancomycin. On the basis of the results of this study, intraarticular application of vancomycin powder in total hip and knee arthroplasty may be considered. Prospective randomized studies have to confirm this promising results prior a common recommendation.Level of Evidence III Retrospective cohort study.
In an effort to identify novel drugs targeting fusion-oncogene–induced acute myeloid leukemia (AML), we performed high-resolution proteomic analysis. In AML1-ETO (AE)-driven AML, we uncovered a deregulation of phospholipase C (PLC) signaling. We identified PLCgamma 1 (PLCG1) as a specific target of the AE fusion protein that is induced after AE binding to intergenic regulatory DNA elements. Genetic inactivation of PLCG1 in murine and human AML inhibited AML1-ETO dependent self-renewal programs, leukemic proliferation, and leukemia maintenance in vivo. In contrast, PLCG1 was dispensable for normal hematopoietic stem and progenitor cell function. These findings are extended to and confirmed by pharmacologic perturbation of Ca++-signaling in AML1-ETO AML cells, indicating that the PLCG1 pathway poses an important therapeutic target for AML1-ETO+ leukemic stem cells.
The present paper is concerned with the investigation of the phenomenon of long-term bone remodelling on cementless hip replacements. Changes in bone density in the periprosthetic region around the stem, measured by dual X–ray absorptiometry (DXA), were used as a measure of the osseous adaptation reaction. A postoperative follow-up of the use of four different types of prostheses of varying design after on average 13.3 (11.4–14.5) years. Specifically, the prostheses assessed in this study were the CLS/Spotorno stem with the Allofit cup by Zimmer, the Vision 2000 stem with the Duraloc cup by DePuy Synthes, the AlphaFit stem with the AlphaLock cup by Corin and the Mayo stem with the Trilogy cup by Zimmer. For the DXA measurement, the femur was divided into the zones suggested by Gruenet al. On the femur, there was a significant reduction in bone mineral density (BMD) in the proximal Region Of Interest (ROI) 1 (p = 0.003) and 7 (p < 0.001), whilst there was a significant increase in ROI 4 (p = 0.03). A greater degree of bone atrophy was seen in patients aged 60 years and older and in female patients. A remarkable finding when comparing the stems was a significantly greater reduction in BMD in ROI 6 (p = 0.003) in the case of the Vision 2000 stem and a markedly, but not statistically significantly smaller reduction in BMD in ROI 7 (p = 0.18) in the case of the short-stem Mayo-type prosthesis. The best clinical results were found with the use of the latter. The investigations provide a starting point for establishing a differential indication in the choice of prosthesis types, depending on age and sex, the use of short-stem prostheses, as well as the administration of bone-effective drugs for the prevention of stress shielding.
Purpose: The cementless implantation of hip replacement cups may be performed with and without the additional use of acetabular screws. If the surgeon uses screws or not depends on variable factors. In general, the use of screws is intended to increase the primary stability of the cup. Whether screws increase the initial stability of the cup construct, or even reduce it in part, is the subject of considerable debate in the literature. It is also unclear whether the additional screws lead to increased wear or increased periacetabular osteolysis over the long-term course. Methods: Two hundred eleven patients from a previous study with a minimum follow-up of 10.7 years were included. Of these, 68 patients with 82 total hip arthroplasties (THA) were given clinical and radiological follow-up examinations. Of these, 52 had been fitted without screws and 30 with screws. On the basis of radiographs, annual wear and osteolysis were quantified. The clinical results were recorded by means of VAS, HHS, and WOMAC scores. Results: Significantly more periacetabular osteolysis was found if additive acetabular screws had been used. No difference was found in relation to the volumetric wear per year. Likewise, no difference was found with regard to the clinical scores. Conclusions: The use of additive acetabular screws leads to increased osteolysis in the periacetabular bone stock. Insofar as the primary stability of the cementless cup construct allows it, no additional acetabular screws should be used.