Sabrina Böhle

Dr. Sabrina Böhle

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
EREric Röhner
Eric Röhner
AMAnke Mayfarth
Anke Mayfarth
CSChristian Sternitzke
Christian Sternitzke
FLFrank Layher
Frank Layher
ASAndrea Scheidig
Andrea Scheidig
KSKlaus Sander
Klaus Sander
There are multiple attempts to decrease costs in the healthcare system while maintaining a high treatment quality. Digital therapies receive increasing attention in clinical practice, mainly relating to home-based exercises supported by mobile devices, eventually in combination with wearable sensors. The aim of this study was to determine if patients following total hip arthroplasty (THA) could benefit from gait training on crutches conducted by a mobile robot in a clinical setting. Method: This clinical trial was conducted with 30 patients following total hip arthroplasty. Fifteen patients received the conventional physiotherapy program in the clinic (including 5 min of gait training supported by a physiotherapist). The intervention group of 15 patients passed the same standard physiotherapy program, but the 5-min gait training supported by a physiotherapist was replaced by 2 × 5 min of gait training conducted by the robot. Length of stay of the patients was set to five days. Biomechanical gait parameters of the patients were assessed pre-surgery and upon patient discharge. Results: While before surgery no significant difference in gait parameters was existent, patients from the intervention group showed a significant higher absolute walking speed (0.83 vs. 0.65 m/s, p = 0.029), higher relative walking speed (0.2 vs. 0.16 m/s, p = 0.043) or shorter relative cycle time (3.35 vs. 3.68 s, p = 0.041) than the patients from the control group. Conclusion: The significant higher walking speed of patients indicates that such robot-based gait training on crutches may shorten length of stay (LOS) in acute clinics. However, the number of patients involved was rather small, thus calling for further studies.

18 March 2021 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Open access
PDF file
SBSabrina Böhle
Sabrina Böhle
EREric Röhner
Eric Röhner
TZTimo Zippelius
Timo Zippelius
BJBenjamin Jacob
Benjamin Jacob
GMGeorg Matziolis
Georg Matziolis
SRSebastian Rohe
Sebastian Rohe
Purpose: Soft tissue, bone and joint infections are severe complications in orthopedic and traumatological surgery. Lavanox (0.08% NaOCl) and Irrisept (0.05% chlorhexidine gluconate, CHG) are industrially produced antiseptic solutions commonly used in infection treatment. Regarding this clinical indication, the microbicidal effect is often investigated, but toxicity to osteoblasts has rarely been examined. This is important to decide whether these solutions should be used in septic situations in which bone healing must take place. The hypothesis of the present study is that NaOCl and CHG are cytotoxic to osteoblasts even after a short exposure time. Methods: Human osteoblasts were isolated from donors with osteoarthritis during total knee and hip arthroplasty. Cells were cultivated and treated with both antiseptic solutions for 2, 5 and 10 min in different dilutions. Toxicity was quantified by counting cells, lactate dehydrogenase (LDH) expression, spectrophotometric quantification via XTT assay and FDA/PI fluorescence microscopy. Results: Analyzing viable cells after treatment with both antiseptics showed a significant decrease in viable cells through LDH expression test, XTT assay, fluorescence microscopy and light microscopy, depending on concentration. The time dependence showed a trend to more cell death at longer exposure times, without significance. Conclusion: Toxic effects on osteoblasts were shown after treatment with 0.08% NaOCl and 0.05% CHG after an exposure time of 2 min which also was concentration dependent. There was no difference in cytotoxicity between both antiseptics. In conclusion, these antiseptic solutions may be used with caution in situations requiring bone healing. Trial registration number Local ethics committee registration number: 5176–07/16

25 January 2024 in Global Spine Journal
Verified
Journal Article
Open access
SVSophia Vogt
Sophia Vogt
CSCarolin Scholl
Carolin Scholl
PGPriyanka Grover
Priyanka Grover
JMJulian Marks
Julian Marks
MDMarcel Dreischarf
Marcel Dreischarf
SBSabrina Böhle
Sabrina Böhle
Study Design: Retrospective, mono-centric cohort research study. Objectives: The analysis of cervical sagittal balance parameters is essential for preoperative planning and dependent on the physician’s experience. A fully automated artificial intelligence-based algorithm could contribute to an objective analysis and save time. Therefore, this algorithm should be validated in this study. Methods: Two surgeons measured C2-C7 lordosis, C1-C7 Sagittal Vertical Axis (SVA), C2-C7-SVA, C7-slope and T1-slope in pre- and postoperative lateral cervical X-rays of 129 patients undergoing anterior cervical surgery. All parameters were measured twice by surgeons and compared to the measurements by the AI algorithm consisting of 4 deep convolutional neural networks. Agreement between raters was quantified, among other metrics, by mean errors and single measure intraclass correlation coefficients for absolute agreement. Results: ICC-values for intra- (range: .92-1.0) and inter-rater (.91-1.0) reliability reflect excellent agreement between human raters. The AI-algorithm could determine all parameters with excellent ICC-values (preop:0.80-1.0; postop:0.86-.99). For a comparison between the AI algorithm and 1 surgeon, mean errors were smallest for C1-C7 SVA (preop: −.3 mm (95% CI:-.6 to −.1 mm), post: .3 mm (.0-.7 mm)) and largest for C2-C7 lordosis (preop:-2.2° (−2.9 to −1.6°), postop: 2.3°(-3.0 to −1.7°)). The automatic measurement was possible in 99% and 98% of pre- and postoperative images for all parameters except T1 slope, which had a detection rate of 48% and 51% in pre- and postoperative images. Conclusion: This study validates that an AI-algorithm can reliably measure cervical sagittal balance parameters automatically in patients suffering from degenerative spinal diseases. It may simplify manual measurements and autonomously analyze large-scale datasets. Further studies are required to validate the algorithm on a larger and more diverse patient cohort.

1 January 2022 in Clinics in Orthopedic Surgery
Verified
Journal Article
Open access
PDF file
SRSebastian Rohe
Sebastian Rohe
EREric Röhner
Eric Röhner
CWChristoph Windisch
Christoph Windisch
GMGeorg Matziolis
Georg Matziolis
SBSteffen Brodt
Steffen Brodt
SBSabrina Böhle
Sabrina Böhle
Rohe S, et al. Clin Orthop Surg. 2022 Feb;14:e5. https://doi.org/10.4055/cios21110

24 May 2022 in Medicina
Verified
Journal Article
Open access
PDF file
NWNele Wagener
Nele Wagener
SBSabrina Böhle
Sabrina Böhle
JKJulia Kirschberg
Julia Kirschberg
SRSebastian Rohe
Sebastian Rohe
MHMarkus Heinecke
Markus Heinecke
EREric Röhner
Eric Röhner
Background and Objectives: No gold standard exists for treating persistent periprosthetic knee infections. Knee arthrodesis represents one treatment concept for extensive bone defects and extensor system insufficiencies. It has already been shown that knee arthrodesis leads to a significant reduction in one’s quality of life. The aim of this survey was to assess the influence of knee arthrodesis on the neighboring joints on the basis of gait analysis data. Our hypothesis is that the hip and ankle joints are negatively influenced by knee arthrodesis in the process of walking. Materials and methods: We performed six pedobarographic and four gait analytical measurements in six patients 2.4 ± 1.6 years after receiving knee arthrodesis at the operating ages of 69.1 ± 9.2 years. Gait analysis consisted of time–distance parameters/minute (number of steps, double support, cycle time, standing phase, step length, gait speed). A healthy group of test subjects (n = 52) was included as the control cohort. Gait analysis was conducted using a three-dimensional movement system and three force-measuring platforms to determine the ground reaction force. Foot pressure was measured using a pedography platform. Results: Five of six patients presented an incomplete rolling movement over the toes on the side that was operated on, presenting with a gait line ending in the forefoot area. All of the patients bore less weight on the side that was operated on. Three of six patients demonstrated a pathological gait line with a healthy opposite side ending in the forefoot area. All of the patients exhibited a reduction in gait speed and step length and a lower number of steps. All of the patients had a prolonged double support/cycle time. Conclusions: Isolated knee arthrodesis is associated with reduced forefoot repulsion, restricted movement on the side receiving the operation, and reduced movement in the ankle/knee joint. The hip showed norm deviations in the hip moment/angle. Knee arthrodesis causes reduced gait kinetics/kinematics. Our survey shows that the relative joint moments of the ankle joint and hip are often reduced. The ankle joint is more affected compared to the hip.

Verified
Journal Article
Open access
PDF file
SRSebastian Rohe
Sebastian Rohe
PSPatrick Strube
Patrick Strube
AHAlexander Hölzl
Alexander Hölzl
SBSabrina Böhle
Sabrina Böhle
TZTimo Zippelius
Timo Zippelius
CLChris Lindemann
Chris Lindemann
This study investigates the advantages and disadvantages of cone-beam-based navigated standardized posterior lumbar interbody fusion surgery (PLIF), regarding the radiation exposure and perioperative time management, compared to the use of fluoroscopy. Patients treated receiving an elective one- to three-level PLIF were retrospectively enrolled in the study. The surgery time, preparation time, operation room time, and effective dose (mSv) were analyzed for comparison of the radiation exposure and time consumption between cone-beam and fluoroscopy; Results: 214 patients were included (108 cone-beam navigated, and 106 traditional fluoroscopies). Using cone-beam navigation, reductions in the effective dose (2.23 ± 1.96 mSv vs. 3.39 ± 2.32 mSv, p = 0.002) and mean surgery time of 30 min (143.62 ± 43.87 min vs. 171.10 ± 48.91 min, p < 0.001) were demonstrated, which leveled out the extended preparation time of 7–8 min (37.25 ± 9.99 min vs. 29.65 ± 7.69 min, p < 0.001). These effects were fusion length dependent and demonstrated additional benefits in multisegmental surgeries. The cone-beam navigation system led to a reduction in the perioperative time requirements and radiation exposure. Furthermore, the controversially discussed longer preparation time when using cone-beam navigation was amortized by a shortened surgery time, especially in multilevel surgery.