Eduard Schreibmann

Dr. Eduard Schreibmann


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2014 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
ESEduard Schreibmann
Eduard Schreibmann
DMDavid M. Marcus
David M. Marcus
TFTim Fox
Tim Fox
Segmentation of organs at risk (OARs) remains one of the most time‐consuming tasks in radiotherapy treatment planning. Atlas‐based segmentation methods using single templates have emerged as a practical approach to automate the process for brain or head and neck anatomy, but pose significant challenges in regions where large interpatient variations are present. We show that significant changes are needed to autosegment thoracic and abdominal datasets by combining multi‐atlas deformable registration with a level set‐based local search. Segmentation is hierarchical, with a first stage detecting bulk organ location, and a second step adapting the segmentation to fine details present in the patient scan. The first stage is based on warping multiple presegmented templates to the new patient anatomy using a multimodality deformable registration algorithm able to cope with changes in scanning conditions and artifacts. These segmentations are compacted in a probabilistic map of organ shape using the STAPLE algorithm. Final segmentation is obtained by adjusting the probability map for each organ type, using customized combinations of delineation filters exploiting prior knowledge of organ characteristics. Validation is performed by comparing automated and manual segmentation using the Dice coefficient, measured at an average of 0.971 for the aorta, 0.869 for the trachea, 0.958 for the lungs, 0.788 for the heart, 0.912 for the liver, 0.884 for the kidneys, 0.888 for the vertebrae, 0.863 for the spleen, and 0.740 for the spinal cord. Accurate atlas segmentation for abdominal and thoracic regions can be achieved with the usage of a multi‐atlas and perstructure refinement strategy. To improve clinical workflow and efficiency, the algorithm was embedded in a software service, applying the algorithm automatically on acquired scans without any user interaction.PACS numbers: 87.57.nm, 87.57.N‐, 87.57.Q‐

6 September 2012 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
ESEduard Schreibmann
Eduard Schreibmann
PPPaul Pantalone
Paul Pantalone
AWAnthony Waller
Anthony Waller
TFTim Fox
Tim Fox
Deformable registration has migrated from a research topic to a widely used clinical tool that can improve radiotherapeutic treatment accuracy by tracking anatomical changes. Although various mathematical formulations have been reported in the literature and implemented in commercial software, we lack a straightforward method to verify a given solution in routine clinical use. We propose a metric using concepts derived from vector analysis that complements the standard evaluation tools to identify unrealistic wrappings in a displacement field. At the heart of the proposed procedure is identification of vortexes in the displacement field that do not correspond to underlying anatomical changes. Vortexes are detected and their intensity quantified using the CURL operator and presented as a vortex map overlaid on the original anatomy for rapid identification of problematic regions. We show application of the proposed metric on clinical scenarios of adaptive radiotherapy and treatment response assessment, where the CURL operator quantitatively detected errors in the displacement field and identified problematic regions that were invisible to classical voxel-based evaluation methods. Unrealistic warping not visible to standard voxel-based solution assessment can produce erroneous results when the deformable solution is applied on a secondary dataset, such as dose matrix in adaptive therapy or PET data for treatment response assessment. The proposed metric for evaluating deformable registration provides increased usability and accuracy of detecting unrealistic deformable registration solutions when compared to standard intensity-based approaches. It is computationally efficient and provides a valuable platform for the clinical acceptance of image-guided radiotherapy. PACS numbers: 87.57.nj; 87.55.Qr; 87.57.cp

6 March 2014 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
ESEduard Schreibmann
Eduard Schreibmann
TFTim Fox
Tim Fox
Treatment planning for volumetric arc therapy (VMAT) is a lengthy process that requires many rounds of optimizations to obtain the best treatment settings and optimization constraints for a given patient's geometry. We propose a feature‐selection search engine that explores previously treated cases of similar anatomy, returning the optimal plan configurations and attainable DVH constraints. Using an institutional database of 83 previously treated cases of prostate carcinoma treated with volumetric‐modulated arc therapy, the search procedure first finds the optimal isocenter position with an optimization procedure, then ranks the anatomical similarity as the mean distance between targets. For the best matching plan, the planning information is reformatted to the DICOM format and imported into the treatment planning system to suggest isocenter, arc directions, MLC patterns, and optimization constraints that can be used as starting points in the optimization process. The approach was tested to create prospective treatment plans based on anatomical features that match previously treated cases from the institution database. By starting from a near‐optimal solution and using previous optimization constraints, the best matching test only required simple optimization steps to further decrease target inhomogeneity, ultimately reducing time spend by the therapist in planning arcs' directions and lengths.PACS number: 87.55.D‐, 87.55.de

3 March 2022 in Tomography
Verified
Journal Article
Open access
PDF file
KXKaren Xu
Karen Xu
KRKarthik Ramesh
Karthik Ramesh
VHVicki Huang
Vicki Huang
SGSaumya Gurbani
Saumya Gurbani
JCJames Scott Cordova
James Scott Cordova
HSHyunsuk Shim
Hyunsuk Shim
Glioblastoma (GBM) is highly aggressive and has a poor prognosis. Belinostat is a histone deacetylase inhibitor with blood–brain barrier permeability, anti-GBM activity, and the potential to enhance chemoradiation. The purpose of this clinical trial was to assess the efficacy of combining belinostat with standard-of-care therapy. Thirteen patients were enrolled in each of control and belinostat cohorts. The belinostat cohort was given a belinostat regimen (500–750 mg/m2 1×/day × 5 days) every three weeks (weeks 0, 3, and 6 of RT). All patients received temozolomide and radiation therapy (RT). RT margins of 5–10 mm were added to generate clinical tumor volumes and 3 mm added to create planning target volumes. Median overall survival (OS) was 15.8 months for the control cohort and 18.5 months for the belinostat cohort (p = 0.53). The recurrence volumes (rGTVs) for the control cohort occurred in areas that received higher radiation doses than that in the belinostat cohort. For those belinostat patients who experienced out-of-field recurrence, tumors were detectable by spectroscopic MRI before RT. Recurrence analysis suggests better in-field control with belinostat. This study highlights the potential of belinostat as a synergistic therapeutic agent for GBM. It may be particularly beneficial to combine this radio-sensitizing effect with spectroscopic MRI-guided RT.

1 September 2016 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
ESEduard Schreibmann
Eduard Schreibmann
DSDavid Schuster
David Schuster
PRPeter J. Rossi
Peter J. Rossi
JSJoseph Shelton
Joseph Shelton
SCSherrie Cooper
Sherrie Cooper
AJAshesh B. Jani
Ashesh B. Jani

26 August 2014 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
RRRaj S Rajpara
Raj S Rajpara
ESEduard Schreibmann
Eduard Schreibmann
TFTim Fox
Tim Fox
LSLiza J Stapleford
Liza J Stapleford
JBJonathan J Beitler
Jonathan J Beitler
KHKristin A Higgins
Kristin A Higgins
Locoregional tumor failure (LRF) after definitive chemoradiation for patients with stage III NSCLC remains unacceptably high. This analysis sought to further define where LRF occurs relative to radiation dose received and pre-treatment PET scan-defined maximum standard uptake value (SUVmax). This was a retrospective study analyzing patients with stage III NSCLC treated with definitive radiation between 2006 and 2011. LRF was defined as failure within the ipsilateral lung, hilum or mediastinum. The CT simulation scan with the radiation dose distribution was registered to the CT or PET/CT documenting LRF. The region of LRF was contoured, and the dose to 95% of the volume (D95) of LRF was extracted. The pre-treatment SUVmax was also extracted for the anatomic region of LRF. Sixty-one patients were identified. Median follow-up time was 19.1 months (range 2.37-76.33). Seventy four percent of patients were treated with 3-D conformal technique (3DCRT), 15% were treated with Intensity Modulated Radiotherapy (IMRT), and 11% were treated with a combination of 3DCRT and IMRT. Median prescribed radiation dose for all patients was 66 Gy (39.6-74). Concurrent chemotherapy was delivered in 90% of patients. Twenty-two patients (36%) developed a LRF, with a total of 39 anatomic regions of LRF identified. Median time to LRF was 11.4 months (3.5-44.6). Failures were distributed as follows: 36% were in-field failures, 27% were out-of-field failures, 18% were in-field and out-of-field failures, and 18% were in-field and marginal (recurrences within the field edge) failures. There were no isolated marginal failures. Of the patients that developed a LRF, 73% developed a LRF with an in-field component. Sixty-two percent of LRFs were nodal. The median pre-treatment SUVmax for the anatomic region of LRF for patients with an in-field failure was 13. The median D95 of in-field LRF was 63 Gy. LRF after definitive chemoradiation are comprised primarily of in-field failures, though out-of field failures are not insignificant. Marginal failures are rare, indicating field margins are appropriate. Although radiation dose escalation to standard radiation fields has not yielded success, using PET parameters to define high-risk regions remains worthy of further investigation.