Hwigon Kim

Mr. Hwigon Kim

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HKHwigon Kim
Hwigon Kim
HJHyun-Sam Jung
Hyun-Sam Jung
SSSeung-Ki Sul
Seung-Ki Sul
The interior permanent-magnet synchronous motor (IPMSM) has been widely used as the traction motor in electric/hybrid vehicles because of its high torque density and wide operating speed range. During the operation of the IPMSM, the stator winding temperature and magnet temperature should be monitored to prevent winding insulation breakdown and irreversible demagnetization and to improve the torque accuracy. This article devised a method involving the use of a high-frequency (HF) resistance and an HF inductance for estimating these two temperatures at low motor speeds. The relationship between the HF impedance and both temperatures was determined and verified using an experimental setup in which both temperatures could be measured. Based on the relation, the temperature estimation method has been proposed, in this article, and verified by the experimental test. The proposed method was used to estimate the stator winding and the magnet temperatures simultaneously for 6000 s, and the maximum error was 6 °C and 3 °C for the stator winding and magnet temperature, respectively, even when the load and the temperatures varied considerably.

20 December 2018 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
HJHyun-Sam Jung
Hyun-Sam Jung
DPDonghoon Park
Donghoon Park
HKHwigon Kim
Hwigon Kim
SSSeung-Ki Sul
Seung-Ki Sul
DBDaniel J. Berry
Daniel J. Berry

1 October 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
HJHyun-Sam Jung
Hyun-Sam Jung
HKHwigon Kim
Hwigon Kim
SSSeung-Ki Sul
Seung-Ki Sul
DBDaniel J. Berry
Daniel J. Berry
In this paper, a method to estimate a temperature of NdFeB magnet in an Interior Permanent Magnet Synchronous Motor (IPMSM) has been developed in medium and high speed operating conditions. Fundamental reactive energy is newly brought out and directly used in the developed method to estimate the magnet temperature accurately, which results in higher sensitivity with respect to the magnet temperature variation compared to the conventional methods. It is because the variation of the reactive energy caused by the magnet temperature includes variations of inductances in addition to that of the magnet flux linkage. In the proposed method, a stator resistance error effect caused by a stator temperature is inherently removed without any additional temperature sensor on stator winding. Moreover, the proposed method is robust to an inverter non-linearity effect and AC resistance effect. As a result, the proposed method can estimate the magnet temperature accurately in real-time, even in load variation, regardless of the stator temperature variation. The magnet temperature estimation error has been less than 3.7 oC in the online estimation for 10000 s under wide speed and torque variations.

21 October 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HJHyun-Sam Jung
Hyun-Sam Jung
HKHwigon Kim
Hwigon Kim
SSSeung-Ki Sul
Seung-Ki Sul
DBDaniel J. Berry
Daniel J. Berry
In this paper, a magnet temperature estimation method applicable to an Interior Permanent Magnet Synchronous Machine (IPMSM) at a standstill has been newly devised. Firstly, it is analyzed that an inductance of IPMSM varies according to not only a magnet temperature but also a rotor angle, which is spatial harmonics. The analysis is verified in a small-scaled Motor-Generation set (MG-set), where magnet temperatures can be directly measured. Based on the analysis and experimental results, it is demonstrated that spatial harmonics can make no negligible error in the magnet temperature estimation. Therefore, the estimation method has been newly devised in this paper, considering spatial harmonics. As a result, the devised method can reduce the maximum estimation error from 25.3 oC to 6 oC based on experimental results in the small-scaled MG-set. Additionally, the devised method has been verified as feasible for use in the small-scaled motor and the traction motor of a mass-produced electric vehicle. As a result, the proposed method can estimate the magnet temperature accurately at every rotor position of both motors. Through this on-line estimation, the maximum estimation error is less than 5 oC even when the stator winding temperature is varying in both a small scale motor and the traction motor.

26 October 2021 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
HJHyun-Sam Jung
Hyun-Sam Jung
HKHwigon Kim
Hwigon Kim
SSSeung-Ki Sul
Seung-Ki Sul
DBDaniel J. Berry
Daniel J. Berry
Interior permanent magnet synchronous machine has been widely used in electric vehicles as a traction motor. The magnet temperature is an essential parameter in the permanent magnet motor. While several magnet temperature estimation methods exist for traction motors of electric vehicles, most of them have been developed and verified on low-power-capacity motors, which are operated at a relatively low speed and with a small current. Generally, the magnet temperature increases more rapidly in high speed and high current compared with low speed and low current. This study demonstrates that a reactive-energy-based method could estimate a mass-produced traction motor’s magnet temperature accurately. Furthermore, an indirect measurement method was developed for measuring the magnet temperature without requiring any modification in the motor structure. Finally, it was used to identify the relation between reactive energy and the magnet temperature in a traction motor. Additionally, implementing the reactive-energy-based estimation method was simplified by considering the configuration and estimation accuracy. The implemented method could estimate the magnet temperature in real time even in high-current (300 A) high-speed (6500 r/min, 2723 rad/s in electrical angular speed) operating conditions, regardless of extreme temperature variations. The maximum estimation error was less than 5 °C in an online estimation for 7020 s (1.95 h) in the presence of large variations in the speed and torque.

13 February 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
GPGayoung Park
Gayoung Park
HKHwigon Kim
Hwigon Kim
BCByung-Geuk Cho
Byung-Geuk Cho
SCShenghui Cui
Shenghui Cui
In applications of the dual-active bridge (DAB) converters, minimizing circulating current and maximizing zero-voltage switching (ZVS) capability are crucial to ensure high efficiency and reliable operation. To address these challenges, this article proposes an optimal triple-phase-shift modulation scheme for the DAB converter. The proposed scheme minimizes rms current and achieves ZVS with minimal increase in circulating current across the entire load range. Building on previous modulation strategies, this article introduces a comprehensive ZVS analysis. It establishes precise ZVS criteria by rigorously accounting for the nonlinear voltage characteristics of parasitic MOSFET capacitances and the dynamic circuit behavior during the dead time, factors often simplified or overlooked in prior approaches. Using nonlinear optimization constrained by these precise ZVS criteria, the proposed modulation scheme guarantees a wide ZVS range without requiring excessive circulating current for complete ZVS, significantly reducing both switching and conduction losses. For experimental validation, a 20 kW/50 kHz SiC-based DAB converter was built, where the converter achieved a peak efficiency of 98.8%, thereby confirming the effectiveness of the proposed method.