Representative Publications

View All Publications
7 November 2005 in IEEE Transactions on Power Electronics
Verified
Journal Article
Open access
HRHyung-Min Ryu
Hyung-Min Ryu
JKJang-Hwan Kim
Jang-Hwan Kim
SSSeung-Ki Sul
Seung-Ki Sul
Multiphase motors are usually designed to have the concentrated winding and nonsinusoidal airgap flux density distribution in order to maximize the torque per ampere. This means that the phase voltage of a multiphase motor has the nonsinusoidal waveform. Accordingly, the conventional analysis on a multiphase space vector pulse-width modulation (SVPWM), which is confined to a sinusoidal phase voltage, should be extended to a nonsinusoidal phase voltage. In this paper, based on a multiple d-q spaces concept a novel analysis on a multiphase SVPWM to synthesize an arbitrary nonsinusoidal phase voltage is proposed. Throughout this paper, a five-phase inverter is used as a practical example. The basic concepts can be easily extended to an n-phase inverter.

7 August 2018 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
CHChae-Eun Hwang
Chae-Eun Hwang
YLYounggi Lee
Younggi Lee
SSSeung-Ki Sul
Seung-Ki Sul
In this paper, the theoretical analysis of the position estimation error in position-sensorless operation using pulsating square wave signal injection is presented. The purpose of this paper is to analyze the phenomenon that the position estimation performance varies depending on the injection frequency. Mathematical derivation supported by simulation and experimental results shows hat, in no load condition, the voltage distortion induces position estimation error with 3rd order harmonics if the frequency of injected square wave is the same to the switching frequency. While, if the frequency is a half of the switching frequency or heavier load condition in either injection frequency, the effect of non-ideal characteristics of inverter disappears and there is no 3rd harmonics in the position estimation error. Therefore, only the effect of cross-coupling inductance is reflected in the estimation error. As the result, the position estimation error appears in the form of 6th order harmonics due to the spatial harmonics of inductances, and the error is relatively small compared to the switching frequency injection case. The theoretical analysis was verified by simulation and experimental results.

1 January 1998 in IEEE Transactions on Power Electronics
Verified
Journal Article
Open access
JCJong-Woo Choi
Jong-Woo Choi
SSSeung-Ki Sul
Seung-Ki Sul
In this paper, a new simple current controller with both satisfactory steady-state characteristics and fast transient response is proposed. In this scheme, a reference modification part is incorporated with the generally used synchronous-frame proportional-integral (PI) controller for the fast transient response. Simulation and experimental results are presented and show the effectiveness of the proposed current controller. In the simulation and experimental results, both the current controller and DC-link regulator show conspicuous performance improvement. It is also observed in the simulation and experiment that the proposed current controller has a similar characteristic as the synchronous-frame PI controller in the steady state and as the minimum-time current controller in the transient state.

23 November 2017 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
YLYounggi Lee
Younggi Lee
SSSeung-Ki Sul
Seung-Ki Sul
In this paper, new model-based sensorless control methods are proposed which include independent estimations of position and speed errors and compatible position and speed estimators. Using the proposed position estimator, a unity transfer function can be achieved from the actual position to the estimated position, eliminating the effects of load disturbances. This implies that the position error would ideally be zero, even in a transient state. In addition, the effects of parameter and voltage synthesis errors on the steady-state position error are analyzed. Experimental results verify both the analysis and the effectiveness of the proposed methods under severe load disturbances such as speed transient (20,000 r/min/s) and load torque transient (10 p.u./s). With the proposed methods, position estimation errors are significantly reduced by more than 50% during speed and load torque transients at identical dominant-pole placements, verifying the enhanced tracking capability and robustness of the proposed methods against external load disturbances.

25 January 2018 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
SCShenghui Cui
Shenghui Cui
HLHak-Jun Lee
Hak-Jun Lee
Jae-Jung JungJae-Jung Jung
Jae-Jung Jung
YLYounggi Lee
Younggi Lee
SSSeung-Ki Sul
Seung-Ki Sul
When a single-line-to-ground (SLG) fault occurs on the ac side of the modular multilevel converter (MMC) in an high-voltage direct-current transmission (HVDC) system, it results in the ac-side voltage sag and leads to an instantaneous reduction of the MMC power capacity. Thus, it calls for the fault ride through (FRT) strategy to coordinate two MMC stations in the HVDC system to protect the MMCs against the submodule (SM) capacitor overvoltage in case of the SLG fault. In the meantime, the HVDC system is expected to track the prefault active power as much as possible during the FRT to secure the power system stability. In this paper, a comprehensive FRT strategy is proposed, which is free of interstation communication. The proposed FRT strategy presents fast dynamic response, and it can prevent effectively the MMC SM-capacitor overvoltage and HVDC transmission line overvoltage. Moreover, the second-order voltage and current fluctuations in the HVDC transmission line caused by the grid unbalance are inherently avoided. Validity of the proposed strategy and its superiority over existing methods are demonstrated by simulation of a 200-kV, 400-MW cable-based HVDC system.

20 November 2018 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
YKYong-Cheol Kwon
Yong-Cheol Kwon
JLJoohyun Lee
Joohyun Lee
SSSeung-Ki Sul
Seung-Ki Sul
This paper analyzes the convergence of signal-injection sensorless control (SISC) especially for heavily saturated interior permanent-magnet synchronous motors (IPMSMs). In the analysis, it is revealed that the harmonic inductance and the operating current variation are critical factors in determining the operational limit of SISC. Clear boundary of SISC for an IPMSM can be obtained through the proposed convergence analysis. Based on this analysis, a control algorithm is proposed to extend the operational limit of SISC. With the proposed method, the torque capability under SISC can be maximized. Simulations and experiments are performed to verify the proposed method.