The aim of this study was to identify ultrasonographic findings that show the normal faecal-impacted appendix, in order to avoid unnecessary surgery via a misdiagnosis of acute appendicitis. Of 160 patients who underwent ultrasonography between January 2004 and July 2005 for right lower quadrant pain, 22 cases (including 7 cases confirmed pathologically and 15 confirmed clinically and on follow-up ultrasonography) were diagnosed as a normal faecal-impacted appendix. The criteria that we used to distinguish a faecal-impacted appendix from acute appendicitis include preservation of the normal wall layering of the appendix, maximum mural thickness, presence of peri-appendiceal fat infiltration and increased blood flow in the appendiceal wall. The maximum measured outer diameter of a normal faecal-impacted appendix was 0.54-1.03 cm, with a mean diameter of 0.68 cm. The maximum mural thickness ranged from 0.08 cm to 0.26 cm, with a mean thickness of 0.15 cm. The normal wall layers of the appendix were preserved and no evidence was seen of peri-appendiceal fat infiltration in any case. No demonstrably increased blood flow in the appendiceal wall was observed. In conclusion, faecal impaction increases the outer transverse diameter of the normal appendix, frequently leading to a misdiagnosis of acute appendicitis. Recognition of preservation of the normal layering of the appendiceal wall, smaller maximal outer diameter, thinner maximal mural thickness, the absence of peri-appendiceal mesenteric infiltration and no demonstrably increased blood flow in the appendiceal wall should help to prevent unnecessary surgery.
1 January 2017 in Journal of Korean Medical Science
Background and Objectives: The novel double-pigtail catheter (DPC) has an additional pigtail coiling at the mid-shaft with multiple centripetal side holes. The present study aimed to investigate the advantages and efficacy of DPC in overcoming the complications of conventional single-pigtail catheters (SPC) used to drain pleural effusion. Materials and Methods: Between July 2018 and December 2019, 382 pleural effusion drainage procedures were reviewed retrospectively (DPC, n = 156; SPC without multiple side holes, n = 110; SPC with multiple side holes (SPC + M), n = 116). All patients showed shifting pleural effusions in the decubitus view of the chest radiography. All catheters were 10.2 Fr in diameter. One interventional radiologist performed all procedures and used the same anchoring technique. Complications (dysfunctional retraction, complete dislodgement, blockage, and atraumatic pneumothorax) were compared among the catheters using chi-square and Fisher’s exact tests. Clinical success was defined as an improvement in pleural effusion within three days without additional procedures. Survival analysis was performed to calculate the indwelling time. Results: The dysfunctional retraction rate of DPC was significantly lower than that of the other catheters (p < 0.001). Complete dislodgement did not occur in any of the DPC cases. The clinical success rate of DPC (90.1%) was the highest. The estimated indwelling times were nine (95% confidence interval (CI): 7.3–10.7), eight (95% CI: 6.6–9.4), and seven (95% CI: 6.3–7.7) days for SPC, SPC + M, and DPC, respectively, with DPC showing a significant difference (p < 0.05). Conclusions: DPC had a lower dysfunctional retraction rate compared to conventional drainage catheters. Furthermore, DPC was efficient for pleural effusion drainage with a shorter indwelling time.