Background and Objectives: The novel double-pigtail catheter (DPC) has an additional pigtail coiling at the mid-shaft with multiple centripetal side holes. The present study aimed to investigate the advantages and efficacy of DPC in overcoming the complications of conventional single-pigtail catheters (SPC) used to drain pleural effusion. Materials and Methods: Between July 2018 and December 2019, 382 pleural effusion drainage procedures were reviewed retrospectively (DPC, n = 156; SPC without multiple side holes, n = 110; SPC with multiple side holes (SPC + M), n = 116). All patients showed shifting pleural effusions in the decubitus view of the chest radiography. All catheters were 10.2 Fr in diameter. One interventional radiologist performed all procedures and used the same anchoring technique. Complications (dysfunctional retraction, complete dislodgement, blockage, and atraumatic pneumothorax) were compared among the catheters using chi-square and Fisher’s exact tests. Clinical success was defined as an improvement in pleural effusion within three days without additional procedures. Survival analysis was performed to calculate the indwelling time. Results: The dysfunctional retraction rate of DPC was significantly lower than that of the other catheters (p < 0.001). Complete dislodgement did not occur in any of the DPC cases. The clinical success rate of DPC (90.1%) was the highest. The estimated indwelling times were nine (95% confidence interval (CI): 7.3–10.7), eight (95% CI: 6.6–9.4), and seven (95% CI: 6.3–7.7) days for SPC, SPC + M, and DPC, respectively, with DPC showing a significant difference (p < 0.05). Conclusions: DPC had a lower dysfunctional retraction rate compared to conventional drainage catheters. Furthermore, DPC was efficient for pleural effusion drainage with a shorter indwelling time.
Background and Objectives: The novel double-pigtail catheter (DPC) has an additional pigtail coiling at the mid-shaft with centripetal multiple side holes. The aim of the present study was to investigate the advantages and efficacy of DPC in overcoming the complications of conventional single-pigtail catheters (SPC) used to drain pleural effusion. Materials and Methods: Between July 2018 and December 2019, 382 pleural effusion drainage procedures were reviewed retrospectively (DPC, n = 156; SPC without multiple side holes, n = 110; SPC with multiple side holes [SPC+M], n = 116). All patients showed shifting pleural effusion in the decubitus view of chest radiography. All catheters were 10.2 Fr in diameter. One interventional radiologist performed all procedures and used the same anchoring technique. Complications (dysfunctional retraction, complete dislodgement, blockage, and atraumatic pneumothorax) were compared among the catheters using chi-square and Fisher’s exact tests. Clinical success was defined as improvement in pleural effusion within 3 days without additional procedures. A survival analysis was performed for calculating the indwelling time. Results: The dysfunctional retraction rate of DPC was significantly lower than that of the other catheters (p < .001). Complete dislodgement did not occur in any of the DPC cases. The clinical success rate of DPC (90.1%) was the highest. The estimated indwelling times were nine (95% confidence interval [CI]: 7.3–10.7), eight (95% CI: 6.6–9.4), and seven (95% CI: 6.3–7.7) days for SPC, SPC+M, and DPC, respectively, with DPC showing a significant difference (p < .05). Conclusions: DPC had a lower dysfunctional retraction rate compared to conventional drainage catheters. Furthermore, DPC were efficient for pleural effusion drainage with a shorter indwelling time.
Background/Objectives: In May–Thurner syndrome (MTS)-related iliofemoral deep vein thrombosis (DVT), stent failure remains an important concern; however, the prognostic value of stent parameters and immediate post-stenting venographic findings is not fully defined. This study aimed to evaluate the stent patency outcomes and analyze the effect of various stent-related parameters on the risk of stent occlusion. Methods: This retrospective study included 50 patients with acute iliofemoral DVT secondary to MTS, who underwent thrombectomy followed by iliac vein stenting. Stent diameter, oversizing, stent type, and post-stenting stenosis were evaluated as predictors of primary patency. Kaplan–Meier and Cox proportional hazards analyses were performed. Results: Nine (18%) patients developed stent occlusion within the first year. The overall primary patency rates were 88% and 81.2% at 1 and 2 years, respectively. Stent diameter, oversizing, and stent type were not significantly associated with patency. In contrast, residual stenosis ≥50% on completion venography was strongly predictive of occlusion (hazard ratio, 4.625; p < 0.001). Patients without significant residual stenosis demonstrated superior patency. Conclusions: Thrombectomy with stenting provides excellent mid-term patency in MTS-related DVT, and early stent failure occurs. Residual stenosis ≥50% after stent deployment is the only significant determinant of reocclusion, whereas stent diameter, oversizing, and stent type do not influence outcomes. Achieving complete luminal restoration during the index procedure is critical for achieving long-term patency.