Shin-Ku Lee

Dr. Shin-Ku Lee

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2021 in Energies
Verified
Journal Article
Open access
PDF file
CSChich-Jen Shieh
Chich-Jen Shieh
XZXiao-Feng Zheng
Xiao-Feng Zheng
CHChia-Hsing Hsieh
Chia-Hsing Hsieh
SLShin-Ku Lee
Shin-Ku Lee
Due to the need of good thermal performance, external wall insulation (EWI) is usually made of materials that are not fire resistant and sometimes flammable. That restricts its application to a particular circumstance such as limited building height. Hence, a material with good thermal insulation and fire resistance performance would allow EWI to be more widely applied. This paper introduces a novel material: a silica-based aerogel porous board, which differs itself from mainstream products available in the market because of its outstanding properties, such as low density, high surface area, low thermal conductivity and superhydrophobicity. Herein, its thermal insulation and fire-resistant performance were tested and compared with commercial products. The cone calorimeter analysis results indicated that the aerogel porous board could improve the fire resistance performance. Moreover, the evaluation of thermal insulation performance suggested that the application of an aerogel porous board on the external stone wall of existing buildings can decrease the U-value by 60%. Through the detailed insight into the case-study, it is quite clear that the carbon impact of building stock could be greatly reduced by means of a coherent set of building envelope retrofitting actions based on this innovative heat insulation material, without compromising the fire safety.

30 March 2017 in Sustainability
Verified
Journal Article
Open access
PDF file
CCChen-Yu Chiang
Chen-Yu Chiang
RYRu Yang
Ru Yang
KYKuan-Hsiung Yang
Kuan-Hsiung Yang
SLShin-Ku Lee
Shin-Ku Lee
In this study, a complete evaluation procedure of energy-saving and efficiency improvement for a large-scale hospital retrofit project has been established and successfully validated in Taiwan. The retrofit scheme, in integrating the alternative hot water system, namely, a water source heat pump (WSHP), with the existing HVAC (Heating, Ventilating, and Air-Conditioning) system, enables the capability to meet the cooling and hot water demand simultaneously with a larger safety margin as well as saving energy. In addition, it has been found that the integrated system provides a new source for cooling which can be utilized as a system redundancy in avoiding system shutdown. This is very useful when considering in specific areas in the hospital, such as intensive care unit, or operation rooms, where cooling should not be interrupted on any occasion. In this study, it is validated that the coefficient of performance (COP) of the newly added WSHP system, under heating and cooling mode, is 3.62 and 2.62, respectively. The recorded annual cost reduction by this integrated system is $102,564, with a payback of 1.2 years. The hospital after retrofit has been operating safer, with more redundancy, and more energy-efficient which warrants tremendous potential for implementation in the industry.

9 June 2017 in Indoor and Built Environment
Verified
Journal Article
Closed access
YHYen-Chieh Huang
Yen-Chieh Huang
SLShin-Ku Lee
Shin-Ku Lee
CCChi-Chang Chan
Chi-Chang Chan
SWShui-Jinn Wang
Shui-Jinn Wang
Building integrated photovoltaic (BIPV) systems are a promising strategy to integrate photovoltaic (PV) systems with building materials to reduce construction costs and add aesthetic features. In this study, a fire test in accordance with ISO 834-1:1999, CNS 14803-2010 and ISO 3008:2007 to provide the standard heating curve was carried out to investigate the fire-resistant characteristics based on the breaking behaviour and surface temperature distribution of type I and type II BIPV modules. The BIPV modules tested have both open and hidden junction-box (J-box) designs, with the aim of reducing fire risks. Our results show that the proposed type II BIPV module could resist the simulated room fire test for about 12 min without reducing any risk with regard to the J-box. Furthermore, the type II BIPV module could resist a fire test at temperatures of up to ∼1000℃ for 60 min with better compartment functionality when refractory glasses are employed. The BIPV fire test data reported in this study can help to improve the design and development of BIPV systems.

19 June 2016 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
CSCheng-Chan Shih
Cheng-Chan Shih
RHRichard S. Horng
Richard S. Horng
SLShin-Ku Lee
Shin-Ku Lee
This paper proposed a new approach, combining root cause analysis (RCA), analytic hierarchy process (AHP), and event tree analysis (ETA) in a loop to systematically evaluate various laboratory safety prevention strategies. First, 139 fire accidents were reviewed to identify the root causes and draw out prevention strategies. Most fires were caused due to runaway reactions, operation error and equipment failure, and flammable material release. These mostly occurred in working places of no prompt fire protection. We also used AHP to evaluate the priority of these strategies and found that chemical fire prevention strategy is the most important control element, and strengthening maintenance and safety inspection intensity is the most important action. Also together with our surveys results, we proposed that equipment design is also critical for fire prevention. Therefore a technical improvement was propounded: installing fire detector, automatic sprinkler, and manual extinguisher in the lab hood as proactive fire protections. ETA was then used as a tool to evaluate laboratory fire risks. The results indicated that the total risk of a fire occurring decreases from 0.0351 to 0.0042 without/with equipment taking actions. Establishing such system can make Environment, Health and Safety (EH&S) office not only analyze and prioritize fire prevention policies more practically, but also demonstrate how effective protective equipment improvement can achieve and the probabilities of the initiating event developing into a serious accident or controlled by the existing safety system.

1 January 2016 in International Journal of Photoenergy
Verified
Journal Article
Open access
PDF file
HLHuei-Mei Liu
Huei-Mei Liu
CYChin-Huai Young
Chin-Huai Young
DHDer-Juinn Horng
Der-Juinn Horng
YSYih-Chearng Shiue
Yih-Chearng Shiue
SLShin-Ku Lee
Shin-Ku Lee
Currently, standard semitransparent photovoltaic (PV) modules can largely replace architectural glass installed in the windows, skylights, and facade of a building. Their main features are power generation and transparency, as well as possessing a heat insulating effect. Through heat insulation solar glass (HISG) encapsulation technology, this study improved the structure of a typical semitransparent PV module and explored the use of three types of high-reflectivity heat insulation films to form the HISG building-integrated photovoltaics (BIPV) systems. Subsequently, the authors analyzed the influence of HISG structures on the optical, thermal, and power generation performance of the original semitransparent PV module and the degree to which enhanced performance is possible. The experimental results indicated that the heat insulation performance and power generation of HISGs were both improved. Selecting an appropriate heat insulation film so that a larger amount of reflective solar radiation is absorbed by the back side of the HISG can yield greater enhancement of power generation. The numerical results conducted in this study also indicated that HISG BIPV system not only provides the passive energy needed for power loading in a building, but also decreases the energy consumption of the HVAC system in subtropical and temperate regions.

6 July 2014 in International Journal of Photoenergy
Verified
Journal Article
Open access
PDF file
YHYen-Chieh Huang
Yen-Chieh Huang
CCChi-Chang Chan
Chi-Chang Chan
SKSzu-Chi Kuan
Szu-Chi Kuan
SWShui-Jinn Wang
Shui-Jinn Wang
SLShin-Ku Lee
Shin-Ku Lee
Single-crystal silicon-based solar cells laminated with tempered-glass and ceramic tiles for use in a building’s façade have been developed. The optical, thermal, and electrical properties of the proposed PV module are first evaluated, and then a wind-resistance test is carried out to evaluate the feasibility of installing it in Taiwan. The electrical and deflection characteristics of the proposed PV module did not change significantly after a 50 thermal cycling test and a 200-hour humidity-freeze test, based on IEC 61215 and a wind-resistance test. Finally, the electrical power generation ability of the proposed BIPV system with 1 kWp electrical power capacity was examined. Building information modeling software tools were used to simulate the BIPV system and carry out the energy analysis. The simulation results show a very consistent trend with regard to the actual monthly electricity production of the BIPV system designed in this work. The BIPV system was able to produce an accumulative electrical power of 185 kWh during the 6-month experimental period. In addition, the exterior temperature of the demonstration house was about 10°C lower than the surface of the BIPV system, which could reduce indoor temperature.