Chia-Hsing Hsieh

Mr. Chia-Hsing Hsieh

Industrial Technology Research Institute
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2021 in Energies
Verified
Journal Article
Open access
PDF file
CSChich-Jen Shieh
Chich-Jen Shieh
XZXiao-Feng Zheng
Xiao-Feng Zheng
CHChia-Hsing Hsieh
Chia-Hsing Hsieh
SLShin-Ku Lee
Shin-Ku Lee
Due to the need of good thermal performance, external wall insulation (EWI) is usually made of materials that are not fire resistant and sometimes flammable. That restricts its application to a particular circumstance such as limited building height. Hence, a material with good thermal insulation and fire resistance performance would allow EWI to be more widely applied. This paper introduces a novel material: a silica-based aerogel porous board, which differs itself from mainstream products available in the market because of its outstanding properties, such as low density, high surface area, low thermal conductivity and superhydrophobicity. Herein, its thermal insulation and fire-resistant performance were tested and compared with commercial products. The cone calorimeter analysis results indicated that the aerogel porous board could improve the fire resistance performance. Moreover, the evaluation of thermal insulation performance suggested that the application of an aerogel porous board on the external stone wall of existing buildings can decrease the U-value by 60%. Through the detailed insight into the case-study, it is quite clear that the carbon impact of building stock could be greatly reduced by means of a coherent set of building envelope retrofitting actions based on this innovative heat insulation material, without compromising the fire safety.

18 January 2024 in International Journal of Low-Carbon Technologies
Verified
Journal Article
Open access
PDF file
JZJia-Wei Zheng
Jia-Wei Zheng
HLHong-Yi Lin
Hong-Yi Lin
CHChia-Hsing Hsieh
Chia-Hsing Hsieh
YWYu-Lieh Wu
Yu-Lieh Wu
Kai-Shing YangKai-Shing Yang
Kai-Shing Yang
To maintain strict temperature, humidity, and cleanliness requirements, the cleanrooms of high-tech semiconductor fabrication plants have heating, ventilation, and air conditioning (HVAC) systems, which require substantial amounts of energy. To reduce energy consumption, this study proposes using a wrap-around loop pulsating heat pipe (WLPHP) heat exchanger comprising a pulsating heat pipe for precooling high-temperature outdoor air to reduce relative humidity. The heat absorbed by the heat-pipe evaporator is then transferred to the condenser and released, reducing the energy required to subsequently reheat the air with an HVAC system. The experimental results reveal that the system reduces the required reheating energy and increased the moisture removal rate per unit energy consumption by an average of 24.8% and 33% compared with a typical heat exchanger. Hence, using the WLPHP heat exchanger in HVAC systems could provide large energy savings.

13 April 2021 in Processes
Verified
Journal Article
Open access
PDF file
Kai-Shing YangKai-Shing Yang
Kai-Shing Yang
CSChao Yun Sheng
Chao Yun Sheng
CHChia-Hsing Hsieh
Chia-Hsing Hsieh
MCMin-Lun Chai
Min-Lun Chai
CWChi-Chuan Wang
Chi-Chuan Wang
This study examines the applicability of the ice storage systems in the small commercial refrigerated showcases through experimental analysis. R-404A is used as the working fluid and various influence of parameter settings and improvements, are discussed in details. In the ice storage system, the condenser is changed from air-cooling (refrigeration mode) to an immersion type that is placed in an ice storage tank, the corresponding condensing temperature and pressure are reduced appreciably. This increased the efficiency and can effectively reduce the peak power consumption. The reduction of the condensing temperature and pressure increased the coefficient of performance (COP) from 3.6 (refrigeration mode) to 6.35 (melting mode), effectively enhancing the refrigeration efficiency. The results indicated that the ice storage system could effectively increase the coefficient of performance from 3.6 to 6.35 during ice melting when compared to the conventional refrigeration system. It also can shift approximately 35% of the power during peak hours and lower the energy cost by USD$ 17.13 per month.