Gilles Soulat

Dr. Gilles Soulat

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2019 in JACC: Cardiovascular Imaging
Verified
Journal Article
Open access
OVOlivier Villemain
Olivier Villemain
MCMafalda Correia
Mafalda Correia
EMElie Mousseaux
Elie Mousseaux
JBJérome Baranger
Jérome Baranger
SZSamuel Zarka
Samuel Zarka
EMEmmanuel Messas
Emmanuel Messas
The goal of our study was to investigate the potential of myocardial shear wave imaging (SWI) to quantify the diastolic myocardial stiffness (MS) (kPa) noninvasively in adult healthy volunteers (HVs) and its physiological variation with age, and in hypertrophic cardiomyopathy (HCM) populations with heart failure and preserved ejection function (HFpEF). MS is an important prognostic and diagnostic parameter of the diastolic function. MS is affected by physiological changes but also by pathological alterations of extracellular and cellular tissues. However, the clinical assessment of MS and the diastolic function remains challenging. SWI is a novel ultrasound-based technique that has the potential to provide intrinsic MS noninvasively. We prospectively included 80 adults: 60 HV (divided into 3 groups: 20- to 39-year old patients [n = 20]; 40- to 59-year-old patients [n = 20]; and 60- to 79-year-old patients [n = 20]) and 20 HCM-HFpEF patients. Echocardiography, cardiac magnetic resonance imaging and biological explorations were achieved. MS evaluation was performed using an ultrafast ultrasound scanner with cardiac phased array. The fractional anisotropy of MS was also estimated. MS increased significantly with age in the HV group (the mean MS was 2.59 ± 0.58 kPa, 4.70 ± 0.88 kPa, and 6.08 ± 1.06 kPa for the 20- to 40-year-old, 40- to 60-year-old, and 60- to 80-year-old patient groups, respectively; p < 0.01 between each group). MS was significantly higher in HCM-HFpEF patients than in HV patients (mean MS = 12.68 ± 2.91 kPa vs. 4.47 ± 1.68 kPa, respectively; p < 0.01), with a cut-off at 8 kPa (area under the curve = 0.993; sensitivity = 95%, specificity = 100%). The fractional anisotropy was lower in HCM-HFpEF (mean = 0.133 ± 0.073) than in HV (0.238 ± 0.068) (p < 0.01). Positive correlations were found between MS and diastolic parameters in echocardiography (early diastolic peak/early diastolic mitral annular velocity, r = 0.783; early diastolic peak/transmitral flow propagation velocity, r = 0.616; left atrial volume index, r = 0.623) and with fibrosis markers in cardiac magnetic resonance (late gadolinium enhancement, r = 0.804; myocardial T1 pre-contrast, r = 0.711). MS was found to increase with age in healthy adults and was significantly higher in HCM-HFpEF patients. Myocardial SWI has the potential to become a clinical tool for the diagnostic of diastolic dysfunction. (Non-invasive Evaluation of Myocardial Stiffness by Elastography [Elasto-Cardio]; NCT02537041).

4 June 2020 in Annual Review of Biomedical Engineering
Verified
Journal Article
Closed access
GSGilles Soulat
Gilles Soulat
PMPatrick M. McCarthy
Patrick M. McCarthy
MMMichael Markl
Michael Markl
Magnetic resonance imaging (MRI) has become an important tool for the clinical evaluation of patients with cardiac and vascular diseases. Since its introduction in the late 1980s, quantitative flow imaging with MRI has become a routine part of standard-of-care cardiothoracic and vascular MRI for the assessment of pathological changes in blood flow in patients with cardiovascular disease. More recently, time-resolved flow imaging with velocity encoding along all three flow directions and three-dimensional (3D) anatomic coverage (4D flow MRI) has been developed and applied to enable comprehensive 3D visualization and quantification of hemodynamics throughout the human circulatory system. This article provides an overview of the use of 4D flow applications in different cardiac and vascular regions in the human circulatory system, with a focus on using 4D flow MRI in cardiothoracic and cerebrovascular diseases.

1 April 2019 in Archives of Cardiovascular Diseases
Verified
Journal Article
Closed access
AHAlbert Hagege
Albert Hagege
PRPatricia Réant
Patricia Réant
GHGilbert Habib
Gilbert Habib
TDThibaud Damy
Thibaud Damy
GBGilles Barone-Rochette
Gilles Barone-Rochette
DGDominique P. Germain
Dominique P. Germain

28 January 2015 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
MEMorgane Evin
Morgane Evin
PCPhilippe Cluzel
Philippe Cluzel
JLJerôme Lamy
Jerôme Lamy
DRDavid Rosenbaum
David Rosenbaum
SKSlawek Kusmia
Slawek Kusmia
NKNadjia Kachenoura
Nadjia Kachenoura
Background Left atrium (LA) volumes and function are predictors of cardiovascular events. Because LA function cannot be assessed from cardiovascular magnetic resonance imaging (MRI) using the well-established left ventricular tagging techniques, we hypothesized that adequate feature tracking (FT) applied to conventional cine MRI data could characterize LA function accurately. Methods We studied 10 young (28 ± 7 years) and 10 elderly (64 ± 6 years) healthy subjects, as well as 20 patients with moderate to severe aortic valve stenosis (AVS; 73 ± 15 years, effective aortic valve area: 0.67 ± 0.36 cm2). MRI cine two-, three-, and four-chamber views were analyzed using a newly proposed FT method based on spatial correlation and endocardial detection resulting in: regional and global longitudinal strain and strain rate, radial motion fraction and relative velocity for the three LA motion phases including reservoir, conduit, and LA contraction. Results FT reliability was indicated by a good overlap between tracking results and manual LA endocardial borders, the low error for comparison against theoretical strains introduced in a synthetic phantom and the good inter-observer reproducibility (coefficient of variation < 15%). While all LA functional parameters were significantly impaired in AVS patients (p < 0.04), subclinical age-related variations induced a decreasing trend on all LA parameters but were significant only for radial conduit function parameters (p < 0.03). Finally, LA functional parameters characterized LA alteration in AVS with higher sensitivity than conventional LA volumetric parameters. Conclusions Left atrial FT is feasible on MRI cine images and its addition to conventional analysis tools might enhance the diagnosis value of MRI in many heart diseases. J. Magn. Reson. Imaging 2015;42:379–389.

1 March 2016 in American Journal of Physiology-Heart and Circulatory Physiology
Verified
Journal Article
Closed access
PDF file
MEMorgane Evin
Morgane Evin
ARAlban Redheuil
Alban Redheuil
GSGilles Soulat
Gilles Soulat
LPLudivine Perdrix
Ludivine Perdrix
GAGolmehr Ashrafpoor
Golmehr Ashrafpoor
NKNadjia Kachenoura
Nadjia Kachenoura
Importance of left atrial (LA) phasic function evaluation is increasingly recognized for its incremental value in terms of prognosis and risk stratification. LA phasic deformation in the pathway of normal aging has been characterized using echocardiographic speckle tracking. However, no data are available regarding age-related variations using feature-racking (FT) techniques from standard cine magnetic resonance imaging (MRI). We studied 94 healthy adults (41 ± 14 yr, 47 women), who underwent MRI and Doppler echocardiography on the same day for left ventricular (LV) diastolic function evaluation. From cine MRI, longitudinal strain and strain rate, radial motion fraction, and radial relative velocity, respectively, corresponding to the reservoir, conduit, and LA contraction phases, were measured using dedicated FT software. Longitudinal strain and radial motion fraction decreased gradually and significantly with aging for both reservoir (r > 0.31, P < 0.003) and conduit (r > 0.54, P < 0.001) phases, whereas they remained unchanged during the LA contraction phase. Subsequently, the LA contraction-to-reservoir ratio increased significantly with age (r > 0.44, P < 0.001). Longitudinal strain rate and radial relative velocity significantly decreased with age (reservoir: r = 0.39, P < 0.001, conduit: r > 0.54, P < 0.001), and these associations tended to be stronger in women than in men. Finally, associations of LA functional indexes with age were stronger in individuals with lower transmitral early-to-atrial maximal velocity ratio and mitral annulus maximal longitudinal velocity, as well as higher transmitral early maximal-to-mitral annulus maximal longitudinal velocity ratio, highlighting the LV-LA interplay. Age-related changes in LA phasic function indexes were quantified by cine MRI images using a FT technique and were significantly related to age and LV diastolic function.

1 January 2018 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
JLJérôme Lamy
Jérôme Lamy
GSGilles Soulat
Gilles Soulat
MEMorgane Evin
Morgane Evin
AHAdrian Thomas Huber
Adrian Thomas Huber
ACAlain de Cesare
Alain de Cesare
NKNadjia Kachenoura
Nadjia Kachenoura