5 February 2018 in IEEE Transactions on Medical Imaging
Singular Value Decomposition (SVD) of Ultrafast imaging ultrasonic datasets has recently been shown to build a vector basis far more adapted to the discrimination of tissue and blood flow than the classical Fourier basis, improving by a large factor clutter filtering and blood flow estimation. However the question of optimally estimating the boundary between the tissue subspace and the blood flow subspace remained unanswered. Here, we introduce an efficient estimator for automatic thresholding of subspaces and compare it to an exhaustive list of thirteen estimators that could achieve this task based on the main characteristics of the singular components, namely the singular values, the temporal singular vectors and the spatial singular vectors. The performance of those fourteen estimators was tested in vitro in a large set of controlled experimental conditions with different tissue motion and flow speeds on a phantom. The estimator based on the degree of resemblance of spatial singular vectors outperformed all others. Apart from solving the thresholding problem, the additional benefit with this estimator was its denoising capabilities, strongly increasing the Contrast to Noise ratio and lowering the noise floor by at least 5dB. This confirms that, contrary to conventional clutter filtering techniques that are almost exclusively based on temporal characteristics, efficient clutter filtering of Ultrafast Doppler imaging cannot overlook space. Finally, this estimator was applied in vivo on various organs (human brain, kidney, carotid, and thyroid) and showed efficient clutter filtering and noise suppression, improving largely the dynamic range of the obtained Ultrafast Power Doppler images.
11 October 2017 in Science Translational Medicine
Functional ultrasound imaging with high spatiotemporal resolution monitors brain function in babies.
1 July 2019 in JACC: Cardiovascular Imaging
The goal of our study was to investigate the potential of myocardial shear wave imaging (SWI) to quantify the diastolic myocardial stiffness (MS) (kPa) noninvasively in adult healthy volunteers (HVs) and its physiological variation with age, and in hypertrophic cardiomyopathy (HCM) populations with heart failure and preserved ejection function (HFpEF). MS is an important prognostic and diagnostic parameter of the diastolic function. MS is affected by physiological changes but also by pathological alterations of extracellular and cellular tissues. However, the clinical assessment of MS and the diastolic function remains challenging. SWI is a novel ultrasound-based technique that has the potential to provide intrinsic MS noninvasively. We prospectively included 80 adults: 60 HV (divided into 3 groups: 20- to 39-year old patients [n = 20]; 40- to 59-year-old patients [n = 20]; and 60- to 79-year-old patients [n = 20]) and 20 HCM-HFpEF patients. Echocardiography, cardiac magnetic resonance imaging and biological explorations were achieved. MS evaluation was performed using an ultrafast ultrasound scanner with cardiac phased array. The fractional anisotropy of MS was also estimated. MS increased significantly with age in the HV group (the mean MS was 2.59 ± 0.58 kPa, 4.70 ± 0.88 kPa, and 6.08 ± 1.06 kPa for the 20- to 40-year-old, 40- to 60-year-old, and 60- to 80-year-old patient groups, respectively; p < 0.01 between each group). MS was significantly higher in HCM-HFpEF patients than in HV patients (mean MS = 12.68 ± 2.91 kPa vs. 4.47 ± 1.68 kPa, respectively; p < 0.01), with a cut-off at 8 kPa (area under the curve = 0.993; sensitivity = 95%, specificity = 100%). The fractional anisotropy was lower in HCM-HFpEF (mean = 0.133 ± 0.073) than in HV (0.238 ± 0.068) (p < 0.01). Positive correlations were found between MS and diastolic parameters in echocardiography (early diastolic peak/early diastolic mitral annular velocity, r = 0.783; early diastolic peak/transmitral flow propagation velocity, r = 0.616; left atrial volume index, r = 0.623) and with fibrosis markers in cardiac magnetic resonance (late gadolinium enhancement, r = 0.804; myocardial T1 pre-contrast, r = 0.711). MS was found to increase with age in healthy adults and was significantly higher in HCM-HFpEF patients. Myocardial SWI has the potential to become a clinical tool for the diagnostic of diastolic dysfunction. (Non-invasive Evaluation of Myocardial Stiffness by Elastography [Elasto-Cardio]; NCT02537041).
17 February 2021 in Nature Communications
Clinicians have long been interested in functional brain monitoring, as reversible functional losses often precedes observable irreversible structural insults. By characterizing neonatal functional cerebral networks, resting-state functional connectivity is envisioned to provide early markers of cognitive impairments. Here we present a pioneering bedside deep brain resting-state functional connectivity imaging at 250-μm resolution on human neonates using functional ultrasound. Signal correlations between cerebral regions unveil interhemispheric connectivity in very preterm newborns. Furthermore, fine-grain correlations between homologous pixels are consistent with white/grey matter organization. Finally, dynamic resting-state connectivity reveals a significant occurrence decrease of thalamo-cortical networks for very preterm neonates as compared to control term newborns. The same method also shows abnormal patterns in a congenital seizure disorder case compared with the control group. These results pave the way to infants’ brain continuous monitoring and may enable the identification of abnormal brain development at the bedside.
1 August 2020 in JACC: Cardiovascular Imaging
12 January 2022 in Nature Cardiovascular Research
JLJosé Carlos Villalobos Lizardi
José Carlos Villalobos Lizardi
+5