Regina Eckert

Dr. Regina Eckert

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 September 2019 in Optica
Verified
Journal Article
Open access
PDF file
SCShwetadwip Chowdhury
Shwetadwip Chowdhury
MCMichael Chen
Michael Chen
RERegina Eckert
Regina Eckert
DRDavid Ren
David Ren
FWFan Wu
Fan Wu
LWLaura Waller
Laura Waller
Optical diffraction tomography (ODT) reconstructs a sample’s volumetric refractive index (RI) to create high-contrast, quantitative 3D visualizations of biological samples. However, standard implementations of ODT use interferometric systems, and so are sensitive to phase instabilities, complex mechanical design, and coherent noise. Furthermore, their reconstruction framework is typically limited to weakly scattering samples, and thus excludes a whole class of multiple-scattering samples. Here, we implement a new 3D RI microscopy technique that utilizes a computational multi-slice beam propagation method to invert the optical scattering process and reconstruct high-resolution (NA>1.0) 3D RI distributions of multiple-scattering samples. The method acquires intensity-only measurements from different illumination angles and then solves a nonlinear optimization problem to recover the sample’s 3D RI distribution. We experimentally demonstrate the reconstruction of samples with varying amounts of multiple-scattering: a 3T3 fibroblast cell, a cluster of C. elegans embryos, and a whole C. elegans worm, with lateral and axial resolutions of ≤240  nm and ≤900  nm, respectively. The results of this work lays groundwork for future studies into using optical wavelengths to probe 3D RI distributions of highly scattering biological organisms.

28 June 2018 in Applied Optics
Verified
Journal Article
Closed access
PDF file
RERegina Eckert
Regina Eckert
ZPZachary F. Phillips
Zachary F. Phillips
LWLaura Waller
Laura Waller
Fourier ptychography captures intensity images with varying source patterns (illumination angles) in order to computationally reconstruct large space-bandwidth-product images. Accurate knowledge of the illumination angles is necessary for good image quality; hence, calibration methods are crucial, despite often being impractical or slow. Here, we propose a fast, robust, and accurate self-calibration algorithm that uses only experimentally collected data and general knowledge of the illumination setup. First, our algorithm makes a fast direct estimate of the brightfield illumination angles based on image processing. Then, a more computationally intensive spectral correlation method is used inside the iterative solver to further refine the angle estimates of both brightfield and darkfield images. We demonstrate our method for correcting large and small misalignment artifacts in 2D and 3D Fourier ptychography with different source types: an LED array, a galvo-steered laser, and a high-NA quasi-dome LED illuminator.

1 January 2017
Verified
Conference Paper
Closed access
PDF file
ZPZachary F. Phillips
Zachary F. Phillips
RERegina Eckert
Regina Eckert
LWLaura Waller
Laura Waller
We demonstrate an inexpensive programmable color LED array illuminator with 0.98 numerical aperture (NA), coupled with an auto-calibration procedure, to enable a simple and efficient setup for high-angle Fourier Ptychography in a commercial microscope.

14 February 2023 in Remote Sensing of Environment
Verified
Journal Article
Open access
NCNimrod Carmon
Nimrod Carmon
ABAlexander Berk
Alexander Berk
NBNiklas Bohn
Niklas Bohn
PBPhillip G. Brodrick
Phillip G. Brodrick
JDJeff Dozier
Jeff Dozier
JSJouni Susiluoto
Jouni Susiluoto

24 February 2022 in Biomedical Optics Express
Verified
Journal Article
Closed access
RCRuiming Cao
Ruiming Cao
MKMichael Kellman
Michael Kellman
DRDavid Ren
David Ren
RERegina Eckert
Regina Eckert
LWLaura Waller
Laura Waller
3D phase imaging recovers an object’s volumetric refractive index from intensity and/or holographic measurements. Partially coherent methods, such as illumination-based differential phase contrast (DPC), are particularly simple to implement in a commercial brightfield microscope. 3D DPC acquires images at multiple focus positions and with different illumination source patterns in order to reconstruct 3D refractive index. Here, we present a practical extension of the 3D DPC method that does not require a precise motion stage for scanning the focus and uses optimized illumination patterns for improved performance. The user scans the focus by hand, using the microscope’s focus knob, and the algorithm self-calibrates the axial position to solve for the 3D refractive index of the sample through a computational inverse problem. We further show that the illumination patterns can be optimized by an end-to-end learning procedure. Combining these two, we demonstrate improved 3D DPC with a commercial microscope whose only hardware modification is LED array illumination.

1 January 2016
Verified
Conference Paper
Closed access
PDF file
RERegina Eckert
Regina Eckert
LTLei Tian
Lei Tian
LWLaura Waller
Laura Waller
Fourier ptychography is a computational illumination method for gigapixel-scale reconstruction of high-resolution phase and amplitude information from low-resolution images. We describe an algorithmic self-calibration method for illumination angles and apply it to a dual-axis galvo system with laser illumination.