14 October 2015 in Optica
We demonstrate a new computational illumination technique that achieves a large space–bandwidth–time product, for quantitative phase imaging of unstained live samples in vitro. Microscope lenses can have either a large field of view (FOV) or high resolution, and not both. Fourier ptychographic microscopy (FPM) is a new computational imaging technique that circumvents this limit by fusing information from multiple images taken with different illumination angles. The result is a gigapixel-scale image having both a wide FOV and high resolution, i.e., a large space–bandwidth product. FPM has enormous potential for revolutionizing microscopy and has already found application in digital pathology. However, it suffers from long acquisition times (of the order of minutes), limiting throughput. Faster capture times would not only improve the imaging speed, but also allow studies of live samples, where motion artifacts degrade results. In contrast to fixed (e.g., pathology) slides, live samples are continuously evolving at various spatial and temporal scales. Here, we present a new source coding scheme, along with real-time hardware control, to achieve 0.8 NA resolution across a FOV with subsecond capture times. We propose an improved algorithm and a new initialization scheme, which allow robust phase reconstruction over long time-lapse experiments. We present the first FPM results for both growing and confluent in vitro cell cultures, capturing videos of subcellular dynamical phenomena in popular cell lines undergoing division and migration. Our method opens up FPM to applications with live samples, for observing rare events in both space and time.
16 September 2019 in Optica
Optical diffraction tomography (ODT) reconstructs a sample’s volumetric refractive index (RI) to create high-contrast, quantitative 3D visualizations of biological samples. However, standard implementations of ODT use interferometric systems, and so are sensitive to phase instabilities, complex mechanical design, and coherent noise. Furthermore, their reconstruction framework is typically limited to weakly scattering samples, and thus excludes a whole class of multiple-scattering samples. Here, we implement a new 3D RI microscopy technique that utilizes a computational multi-slice beam propagation method to invert the optical scattering process and reconstruct high-resolution () 3D RI distributions of multiple-scattering samples. The method acquires intensity-only measurements from different illumination angles and then solves a nonlinear optimization problem to recover the sample’s 3D RI distribution. We experimentally demonstrate the reconstruction of samples with varying amounts of multiple-scattering: a 3T3 fibroblast cell, a cluster of C. elegans embryos, and a whole C. elegans worm, with lateral and axial resolutions of and , respectively. The results of this work lays groundwork for future studies into using optical wavelengths to probe 3D RI distributions of highly scattering biological organisms.
2 February 2017 in PLOS ONE
We present a new technique for quantitative phase and amplitude microscopy from a single color image with coded illumination. Our system consists of a commercial brightfield microscope with one hardware modification—an inexpensive 3D printed condenser insert. The method, color-multiplexed Differential Phase Contrast (cDPC), is a single-shot variant of Differential Phase Contrast (DPC), which recovers the phase of a sample from images with asymmetric illumination. We employ partially coherent illumination to achieve resolution corresponding to 2× the objective NA. Quantitative phase can then be used to synthesize DIC and phase contrast images or extract shape and density. We demonstrate amplitude and phase recovery at camera-limited frame rates (50 fps) for various in vitro cell samples and c. elegans in a micro-fluidic channel.
30 November 2018 in Optics Express
Differential Phase Contrast (DPC) microscopy is a practical method for recovering quantitative phase from intensity images captured with different source patterns in an LED array microscope. Being a partially coherent imaging method, DPC does not suffer from speckle artifacts and achieves 2× better resolution than coherent methods. Like all imaging systems, however, DPC is susceptible to aberrations. Here, we propose a method of algorithmic self-calibration for DPC where we simultaneously recover the complex-field of the sample and the spatially-variant aberrations of the system, using 4 images with different illumination source patterns. The resulting phase reconstructions are digitally aberration-corrected.