凯博 胡

凯博 胡


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
XLXinyue Liu
Xinyue Liu
Yan YanYan Yan
Yan Yan
凯胡凯博 胡
凯博 胡
SZShan Zhang
Shan Zhang
HLHongjie Li
Hongjie Li
Tingna ShiTingna Shi
Tingna Shi
When an induction motor is running at stable speed and low slip, the fault signal of the induction motor’s broken bar faults are easily submerged by the power frequency (50 Hz) signal. Thus, it is difficult to extract fault characteristics. The left-side harmonic component representing the fault characteristics can be distinguished from power frequency owing to V-shaped trajectory of the fault component in time-frequency (t-f) domain during motor startup. This article proposed a scheme to detect broken bar faults and discriminate the severity of faults under starting conditions. In this scheme, successive variable mode decomposition (SVMD) is applied to analyze the stator starting current to extract the fault component, and the signal reconstruction is proposed to maximize the energy of the fault component. Then, the quadratic regression curve method of instantaneous frequency square value of the fault component is utilized to discriminate whether the fault occurs. In addition, according to the feature that the energy of the fault component increases with the fault severity, the energy of the right part of the fault component is proposed to detect the severity of the fault. In this paper, experiments are carried out based on a 5.5 kW three-pole induction motor. The results show that the scheme proposed in this paper can diagnose the broken bar faults and determine the severity of the fault.

5 June 2026 in Frontiers in Smart Grids
Verified
Journal Article
Open access
PDF file
凯胡凯博 胡
凯博 胡
LYLifeng Yu
Lifeng Yu
WGWuyin Gu
Wuyin Gu
KQKefeng Qian
Kefeng Qian
JSJiahe Sun
Jiahe Sun
Power transformers are critical equipment in power systems, and their operational reliability directly affects the safety and stability of grid operation. Conventional transformer operation and maintenance methods are often limited by fixed alarm rules and insufficient integration of monitoring information, making it difficult to achieve intelligent fault diagnosis and timely warning support. To address these issues, this paper proposes a digital twin-assisted framework for transformer fault diagnosis and early warning by integrating transformer digital modeling, online monitoring information, and dissolved gas analysis (DGA)-based intelligent diagnosis. A three-dimensional transformer digital model is constructed using laser point cloud reconstruction and parametric modeling to support equipment state representation and information mapping. Meanwhile, a Snake Optimization-Random Forest (SO-RF) model is developed for multi-class transformer fault diagnosis using five characteristic dissolved gas features. The proposed model is trained and tested using dissolved gas data from a power company's transformer fault case library and compared with Support Vector Machine (SVM) and Random Forest (RF) models. Experimental results show that the proposed SO-RF model achieves an overall diagnostic accuracy of 93.80%, which is higher than those of RF and SVM, with accuracies of 89.98% and 86.39%, respectively. The proposed framework provides a feasible technical route for combining data-driven transformer fault diagnosis with digital twin-assisted state visualization and warning support for intelligent transformer operation and maintenance.