Kristin Gilchrist

Dr. Kristin Gilchrist

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2011 in IEEE Journal of Selected Topics in Quantum Electronics
Verified
Journal Article
Closed access
LVLogeeswaran Vj
Logeeswaran Vj
JOJinyong Oh
Jinyong Oh
ANAvinash P. Nayak
Avinash P. Nayak
AKAaron M. Katzenmeyer
Aaron M. Katzenmeyer
KGKristin Gilchrist
Kristin Gilchrist
MIM. Saif Islam
M. Saif Islam
One-dimensional semiconductor nanostructures (nanowires (NWs), nanotubes, nanopillars, nanorods, etc.) based photodetectors (PDs) have been gaining traction in the research community due to their ease of synthesis and unique optical, mechanical, electrical, and thermal properties. Specifically, the physics and technology of NW PDs offer numerous insights and opportunities for nanoscale optoelectronics, photovoltaics, plasmonics, and emerging negative index metamaterials devices. The successful integration of these NW PDs on CMOS-compatible substrates and various low-cost substrates via direct growth and transfer-printing techniques would further enhance and facilitate the adaptation of this technology module in the semiconductor foundries. In this paper, we review the unique advantages of NW-based PDs, current device integration schemes and practical strategies, recent device demonstrations in lateral and vertical process integration with methods to incorporate NWs in PDs via direct growth (nanoepitaxy) methods and transfer-printing methods, and discuss the numerous technical design challenges. In particular, we present an ultrafast surface-illuminated PD with 11.4-ps full-width at half-maximum (FWHM), edge-illuminated novel waveguide PDs, and some novel concepts of light trapping to provide a full-length discussion on the topics of: 1) low-resistance contact and interfaces for NW integration; 2) high-speed design and impedance matching; and 3) CMOS-compatible mass-manufacturable device fabrication. Finally, we offer a brief outlook into the future opportunities of NW PDs for consumer and military application.

26 September 2014 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
DDDavid E. Dausch
David E. Dausch
KGKristin Gilchrist
Kristin Gilchrist
JCJames B. Carlson
James B. Carlson
SHStephen D. Hall
Stephen D. Hall
JCJohn B. Castellucci
John B. Castellucci
OROlaf T. von Ramm
Olaf T. von Ramm
Piezoelectric micromachined ultrasound transducer (PMUT) matrix arrays were fabricated containing novel through-silicon interconnects and integrated into intracardiac catheters for in vivo real-time 3-D imaging. PMUT arrays with rectangular apertures containing 256 and 512 active elements were fabricated and operated at 5 MHz. The arrays were bulk micromachined in silicon-on-insulator substrates, and contained flexural unimorph membranes comprising the device silicon, lead zirconate titanate (PZT), and electrode layers. Through-silicon interconnects were fabricated by depositing a thin-film conformal copper layer in the bulk micromachined via under each PMUT membrane and photolithographically patterning this copper layer on the back of the substrate to facilitate contact with the individually addressable matrix array elements. Cable assemblies containing insulated 45-AWG copper wires and a termination silicon substrate were thermocompression bonded to the PMUT substrate for signal wire interconnection to the PMUT array. Side-viewing 14-Fr catheters were fabricated and introduced through the femoral vein in an adult porcine model. Real-time 3-D images were acquired from the right atrium using a prototype ultrasound scanner. Full 60° × 60° volume sectors were obtained with penetration depth of 8 to 10 cm at frame rates of 26 to 31 volumes per second.

1 October 2015 in Toxicology and Applied Pharmacology
Verified
Journal Article
Closed access
KGKristin Gilchrist
Kristin Gilchrist
GLGregory F. Lewis
Gregory F. Lewis
EGElaine A. Gay
Elaine A. Gay
KSKatelyn L. Sellgren
Katelyn L. Sellgren
SGSonia Grego
Sonia Grego

19 March 2007 in Applied Physics Letters
Verified
Journal Article
Closed access
CBChristopher A. Bower
Christopher A. Bower
KGKristin Gilchrist
Kristin Gilchrist
JPJeffrey R. Piascik
Jeffrey R. Piascik
BSBrian R. Stoner
Brian R. Stoner
SNSrividya Natarajan
Srividya Natarajan
JGJeffrey T. Glass
Jeffrey T. Glass
A lateral on-chip electron-impact ion source utilizing a carbon nanotube field emission electron source was fabricated and characterized. The device consists of a cathode with aligned carbon nanotubes, a control grid, and an ion collector electrode. The electron-impact ionization of He, Ar, and Xe was studied as a function of field emission current and pressure. The ion current was linear with respect to gas pressure from 10−4to10−1Torr. The device can operate as a vacuum ion gauge with a sensitivity of approximately 1Torr−1. Ion currents in excess of 1μA were generated.

1 September 2001 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
KGKristin Gilchrist
Kristin Gilchrist
VBValerie N. Barker
Valerie N. Barker
LFLauren E. Fletcher
Lauren E. Fletcher
BDB.Derek DeBusschere
B.Derek DeBusschere
PGPejman Ghanouni
Pejman Ghanouni
GKGregory T.A. Kovacs
Gregory T.A. Kovacs

15 January 2005 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
KGKristin Gilchrist
Kristin Gilchrist
LGLaurent Giovangrandi
Laurent Giovangrandi
RWR.Hollis Whittington
R.Hollis Whittington
GKGregory T.A. Kovacs
Gregory T.A. Kovacs