David Edward Dausch

David Edward Dausch

Auto-generated profile, based on publicly available information

David Edward Dausch

RTI International, Morrisville, NC, United States

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2003 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
SFStephen H. Foulger
Stephen H. Foulger
PJP. Jiang
P. Jiang
ALA. Lattam
A. Lattam
DSD.W. Smith
D.W. Smith
JBJ. Ballato
J. Ballato
BSB.R. Stoner
B.R. Stoner

26 September 2014 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
DDDavid E. Dausch
David E. Dausch
KGKristin Gilchrist
Kristin Gilchrist
JCJames B. Carlson
James B. Carlson
SHStephen D. Hall
Stephen D. Hall
JCJohn B. Castellucci
John B. Castellucci
OROlaf T. von Ramm
Olaf T. von Ramm
Piezoelectric micromachined ultrasound transducer (PMUT) matrix arrays were fabricated containing novel through-silicon interconnects and integrated into intracardiac catheters for in vivo real-time 3-D imaging. PMUT arrays with rectangular apertures containing 256 and 512 active elements were fabricated and operated at 5 MHz. The arrays were bulk micromachined in silicon-on-insulator substrates, and contained flexural unimorph membranes comprising the device silicon, lead zirconate titanate (PZT), and electrode layers. Through-silicon interconnects were fabricated by depositing a thin-film conformal copper layer in the bulk micromachined via under each PMUT membrane and photolithographically patterning this copper layer on the back of the substrate to facilitate contact with the individually addressable matrix array elements. Cable assemblies containing insulated 45-AWG copper wires and a termination silicon substrate were thermocompression bonded to the PMUT substrate for signal wire interconnection to the PMUT array. Side-viewing 14-Fr catheters were fabricated and introduced through the femoral vein in an adult porcine model. Real-time 3-D images were acquired from the right atrium using a prototype ultrasound scanner. Full 60° × 60° volume sectors were obtained with penetration depth of 8 to 10 cm at frame rates of 26 to 31 volumes per second.

25 November 2008 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
DDDavid E. Dausch
David E. Dausch
JCJohn B. Castellucci
John B. Castellucci
DCDerrick R. Chou
Derrick R. Chou
OROlaf T. von Ramm
Olaf T. von Ramm
Piezoelectric micromachined ultrasound transducers (pMUTs) are a new approach for the construction of 2-D arrays for forward-looking 3-D intravascular (IVUS) and intracardiac (ICE) imaging. Two-dimensional pMUT test arrays containing 25 elements (5 times 5 arrays) were bulk micromachined in silicon substrates. The devices consisted of lead zirconate titanate (PZT) thin film membranes formed by deep reactive ion etching of the silicon substrate. Element widths ranged from 50 to 200 mum with pitch from 100 to 300 mum. Acoustic transmit properties were measured in de-ionized water with a calibrated hydrophone placed at a range of 20 mm. Measured transmit frequencies for the pMUT elements ranged from 4 to 13 MHz, and mode of vibration differed for the various element sizes. Element capacitance varied from 30 to over 400 pF depending on element size and PZT thickness. Smaller element sizes generally produced higher acoustic transmit output as well as higher frequency than larger elements. Thicker PZT layers also produced higher transmit output per unit electric field applied. Due to flexure mode operation above the PZT coercive voltage, transmit output increased nonlinearly with increased drive voltage. The pMUT arrays were attached directly to the Duke University T5 phased array scanner to produce real-time pulse-echo B-mode images with the 2-D pMUT arrays.

1 October 2010
Verified
Conference Paper
Closed access
DDDavid E. Dausch
David E. Dausch
KGKristin Gilchrist
Kristin Gilchrist
JCJames R. Carlson
James R. Carlson
JCJohn B. Castellucci
John B. Castellucci
DCDerrick R. Chou
Derrick R. Chou
OROlaf T. von Ramm
Olaf T. von Ramm
Piezoelectric micromachined ultrasound transducers (pMUTs) are potential candidates for catheter-based ultrasound phased arrays. pMUTs consist of lead zirconate titanate (PZT) thin film membranes formed on silicon substrates and are operated in flexure mode by driving the PZT film above its coercive field to induce flextensional motion. The fundamental operation of pMUT devices has been demonstrated; however, pulse-echo imaging has been limited to date. The objective of this work was to optimize transducer design for improved pulse-echo imaging performance. Flexure mode operation was optimized by (1) increasing transmit voltage above the PZT coercive field to induce ferroelectric domain switching, and (2) using partial cycle transmit pulses to increase the polarization in the PZT thin film and increase receive signal. As a result, pulse-echo images of tissue were obtained. 1-D arrays operating at 5 MHz were capable of resolving targets in a commercial tissue phantom as well as human anatomy. Real-time 3-D imaging was also demonstrated using 2-D arrays at 5 and 12.5 MHz. These results suggest that pMUTs have sufficient performance for application in ultrasound imaging with frequency range suitable for catheter-based phased-array transducers.

25 September 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
HMHamed Mohammadbagherpoor
Hamed Mohammadbagherpoor
PIPaul Ierymenko
Paul Ierymenko
Meghan Hegarty-CraverMeghan Hegarty-Craver
Meghan Hegarty-Craver
JCJim Carlson
Jim Carlson
DDDavid Dausch
David Dausch
JLJohn D. Lucey
John D. Lucey
Currently, the most common method for detecting prosthetic implant loosening is imaging. Unfortunately, imaging methods are imprecise in detecting the early signs of implant loosening. This paper describes a new wireless inductive proximity sensor system for detecting early implant loosening. The loosening of the implant is accurately detected by analyzing the electromagnetic field generated by the passive sensors located around the implant. The sensor system was modeled and simulated using COMSOL, and then tested experimentally. The inductive proximity sensor and the metallic implant form a coupled circuit is tuned to oscillate at a designed frequency. The circuit's integrated controller measures and records specific sensor's parameters such as resistance and inductance of the sensor that are directly related to the distance between the sensor system and the implant. A prototype has been developed and the results show that the designed proximity sensor is capable of measuring the loosening of the hip implant at 50μm resolution at distances of less than 8mm, and of 100μm resolution at a distance of 15mm. Furthermore, there is a good correlation between the simulated and experimental results.

1 January 2006
Verified
Conference Paper
Closed access
DDD. E. Dausch
D. E. Dausch
JCJ. B. Castellucci
J. B. Castellucci
DCD. R. Chou
D. R. Chou
ORO. T. von Ramm
O. T. von Ramm
Piezoelectric micromachined ultrasound transducers (pMUTs) have been fabricated and characterized in this work as a new approach for manufacture of 2D arrays for forward-looking 3D intravascular (IVUS) and intracardiac (ICE) imaging. Two-dimensional pMUT arrays containing 25 elements (5 times 5 arrays) were bulk micromachined in silicon substrates. The devices consisted of suspended PZT thin film membranes formed by deep reactive ion etching. Membrane widths ranged from 50 to 200 mum, with element pitch from 100 to 300 mum. Acoustic transmit properties were measured in de-ionized water with a calibrated hydrophone placed at a range of 20 mm. Measured transmit frequencies for the pMUT elements ranged from 4-11 MHz. Element capacitance for pMUTs ranged from 30 to over 400 pF depending on element size. Smaller element sizes generally produced higher acoustic transmit output than larger elements, and thicker PZT layers also produced higher output per unit electric field applied. Due to flexure mode operation above the PZT coercive voltage, transmit output also increased nonlinearly with increased drive voltage. The pMUT arrays were attached directly to the system amplifiers of the Duke University T5 Phased Array Scanner by a modified cable assembly in order to produce real-time pulse-echo B-mode images with the 2D pMUT arrays