Jaime Castello

Dr. Jaime Castello

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2009 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JCJaime Castello
Jaime Castello
JEJose Miguel Espi
Jose Miguel Espi
RGRafael Garcia-Gil
Rafael Garcia-Gil
SGSergio Alejandro González
Sergio Alejandro González
This paper presents a new predictive control algorithm for grid-connected current-controlled inverters. The control combines a two-sample deadbeat control law with a Luenberger observer to estimate the future value of the grid currents. The resulting control offers robustness against the computational delay inherent in the digital implementation and considerably enhances the gain and phase margins of the previous predictive controls while maintaining the high-speed response typical of the deadbeat controllers.

28 October 2010 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JEJose Miguel Espi
Jose Miguel Espi
JCJaime Castello
Jaime Castello
RGRafael Garcia-Gil
Rafael Garcia-Gil
GGGabriel Garcera
Gabriel Garcera
EFEmilio Figueres
Emilio Figueres
This paper presents an adaptive robust predictive current control (RPCC) for grid-connected three-phase inverters that exhibit zero steady-state current error. The error correction is achieved by means of an adaptive strategy that works in parallel with the deadbeat algorithm, therefore preserving the typical fast response of the predictive law. The resulting control adapts to any particular L or LCL filter by estimation of the resistive part of the filter. As a variety of the RPCC class of control, it offers the best tradeoff between robustness and speed.

7 August 2009 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JEJose Miguel Espi
Jose Miguel Espi
JCJaime Castello
Jaime Castello
JFJonatan Roberto Fischer
Jonatan Roberto Fischer
RGRafael Garcia-Gil
Rafael Garcia-Gil
This paper presents a new predictive current control for three-phase grid-connected inverters in the synchronous reference frame. The control combines a deadbeat control law with a diagonal Luenberger observer to estimate the future value of the grid currents. It provides a decoupled control of the active and reactive power and offers robustness against the computational delay inherent in the digital implementation and against filter and grid-impedance uncertainties. This control exhibits a very fast current response while widely improving the gain and phase margins of the traditional predictive controllers.

1 February 2016 in Renewable Energy
Verified
Journal Article
Closed access
JCJaime Castello
Jaime Castello
JEJose Miguel Espi
Jose Miguel Espi
RGRafael Garcia-Gil
Rafael Garcia-Gil

5 November 2007 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JEJose Miguel Espi
Jose Miguel Espi
ESEnrique J. Dede Garcia Santamaria
Enrique J. Dede Garcia Santamaria
RGRafael Garcia-Gil
Rafael Garcia-Gil
JCJaime Castello
Jaime Castello
This paper presents the new L- LC induction heating generator and probes that, in resonance, are equivalent to a series resonant inverter. This equivalence is then used to compare both topologies, extracting the advantages and disadvantages of the L-LC usage. In addition, based on this equivalence, a design procedure is proposed that covers all possible L-LC configurations. Finally, some experimental results are presented, showing waveforms during normal and short-circuit operation.

3 November 2015 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JCJaime Castello
Jaime Castello
JEJose Miguel Espi
Jose Miguel Espi
RGRafael Garcia-Gil
Rafael Garcia-Gil
In this paper, a new predictive control for grid-connected inverters is presented, which provides the best performance in terms of transient response and stability margins when analog filters in current sensing circuits are used. These filters are necessary to avoid aliasing in the A/D conversion process, which causes an important ripple on injected current into the grid and increases the total harmonic distortion. However, predictive controls are very sensitive to delays on the acquisitions, so when such anti-aliasing filters are used a reduction of stability margins is produced and the transient response is affected. The proposed predictive control allows to compensate the effect of the filter, for any order and cutoff frequency, providing the best transient response in the reference tracking and the highest stability margins. Furthermore, a modification on the adaptive strategy of current error is proposed, which allows to work with single-phase grid-connected inverters. The proposed predictive control has been tested on a 3.3-kVA single-phase grid-connected inverter with LCL filter, using different anti-aliasing filters, obtaining in all cases, better results than those offered by other predictive controls recently published.