This paper presents a new predictive control algorithm for grid-connected current-controlled inverters. The control combines a two-sample deadbeat control law with a Luenberger observer to estimate the future value of the grid currents. The resulting control offers robustness against the computational delay inherent in the digital implementation and considerably enhances the gain and phase margins of the previous predictive controls while maintaining the high-speed response typical of the deadbeat controllers.
28 October 2010 in IEEE Transactions on Industrial Electronics
This paper presents an adaptive robust predictive current control (RPCC) for grid-connected three-phase inverters that exhibit zero steady-state current error. The error correction is achieved by means of an adaptive strategy that works in parallel with the deadbeat algorithm, therefore preserving the typical fast response of the predictive law. The resulting control adapts to any particular L or LCL filter by estimation of the resistive part of the filter. As a variety of the RPCC class of control, it offers the best tradeoff between robustness and speed.
7 August 2009 in IEEE Transactions on Industrial Electronics
This paper presents a new predictive current control for three-phase grid-connected inverters in the synchronous reference frame. The control combines a deadbeat control law with a diagonal Luenberger observer to estimate the future value of the grid currents. It provides a decoupled control of the active and reactive power and offers robustness against the computational delay inherent in the digital implementation and against filter and grid-impedance uncertainties. This control exhibits a very fast current response while widely improving the gain and phase margins of the traditional predictive controllers.
A bidirectional-power-flow three-phase rectifier with high-frequency isolation and all-digital control, based on the matrix converter topology, is analyzed in this paper. The selected topology consists of a bidirectional three-phase-to-single-phase reduced matrix converter with power-factor correction and a bidirectional active rectifier. The inclusion of the isolation transformer at the switching frequency permits the reduction of volume and weight. By synchronizing the commutation of both converters and adding a saturable inductor and a blocking capacitor it is possible to achieve soft commutation for most of the semiconductor elements. An all-digital control based on a digital-signal-processor and a field-programmable gate array was used to implement space-vector modulation and output current regulation. This power converter is intended to feed the low-energy correction magnet of a particle accelerator. Experimental results of a 1.5-kW 20-kHz prototype are presented to illustrate the performance of the proposed topology.
5 November 2007 in IEEE Transactions on Industrial Electronics
This paper presents the new L- LC induction heating generator and probes that, in resonance, are equivalent to a series resonant inverter. This equivalence is then used to compare both topologies, extracting the advantages and disadvantages of the L-LC usage. In addition, based on this equivalence, a design procedure is proposed that covers all possible L-LC configurations. Finally, some experimental results are presented, showing waveforms during normal and short-circuit operation.