Hongyan Cui

Dr. Hongyan Cui


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2023 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
XCXiaogang Chen
Xiaogang Chen
BLBingchuan Liu
Bingchuan Liu
YWYijun Wang
Yijun Wang
HCHongyan Cui
Hongyan Cui
JDJianwei Dong
Jianwei Dong
XGXiaorong Gao
Xiaorong Gao
The brain-computer interfaces (BCIs) based on steady-state visual evoked potential (SSVEP) have been extensively explored due to their advantages in terms of high communication speed and smaller calibration time. The visual stimuli in the low- and medium-frequency ranges are adopted in most of the existing studies for eliciting SSVEPs. However, there is a need to further improve the comfort of these systems. The high-frequency visual stimuli have been used to build BCI systems and are generally considered to significantly improve the visual comfort, but their performance is relatively low. The distinguishability of 16-class SSVEPs encoded by the three frequency ranges, i.e., 31-34.75 Hz with an interval of 0.25 Hz, 31-38.5 Hz with an interval of 0.5 Hz, 31-46 Hz with an interval of 1 Hz, is explored in this study. We compare classification accuracy and information transfer rate (ITR) of the corresponding BCI system. According to the optimized frequency range, this study builds an online 16-target high frequency SSVEP-BCI and verifies the feasibility of the proposed system based on 21 healthy subjects. The BCI based on visual stimuli with the narrowest frequency range, i.e., 31-34.5 Hz, have the highest ITR. Therefore, the narrowest frequency range is adopted to build an online BCI system. An averaged ITR obtained from the online experiment is 153.79 ±6.39 bits/min. These findings contribute to the development of more efficient and comfortable SSVEP-based BCIs.

22 April 2024 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
RZRuoqing Zhang
Ruoqing Zhang
SFShanshan Feng
Shanshan Feng
NHNan Hu
Nan Hu
SLShunkang Low
Shunkang Low
MLMeng Li
Meng Li
HCHongyan Cui
Hongyan Cui
Soft robotic glove controlled by a brain-computer interface (BCI) have demonstrated effectiveness in hand rehabilitation for stroke patients. Current systems mostly rely on static visual representations for patients to perform motor imagination (MI) tasks, resulting in lower BCI performance. Therefore, this study innovatively used MI and high-frequency steady-state visual evoked potential (SSVEP) to construct a friendly and natural hybrid BCI paradigm. Specifically, the stimulation interface sequentially presented decomposed action pictures of the left and right hands gripping a ball, with the pictures flashing at specific stimulation frequencies (left: 34 Hz, right: 35 Hz). Integrating soft robotic glove as feedback, we established a comprehensive “peripheral - central - peripheral” hand rehabilitation system to facilitate the hand rehabilitation of patients. Filter bank common spatial pattern (FBCSP) and filter bank canonical correlation analysis (FBCCA) algorithms were used to identify MI and SSVEP signals, respectively. Additionally, to fuse the features of these two signals, we proposed a novel fusion algorithm for improving the recognition accuracy of the system. The feasibility of the proposed system was validated through online experiments involving 12 healthy subjects and 9 stroke patients, achieving accuracy rates of 95.83 ± 6.83% and 63.33 ± 10.38%, respectively. The accuracy of MI and SSVEP in 12 healthy subjects reached 81.67 ± 15.63% and 95.14 ± 7.47%, both lower than the accuracy after fusion, these results confirmed the effectiveness of the proposed algorithm. The accuracy rate was more than 50% in both healthy subjects and patients, confirming the effectiveness of the proposed system.

3 June 2022 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
XCXinyi Chi
Xinyi Chi
CWChunxiao Wan
Chunxiao Wan
CWChunyan Wang
Chunyan Wang
YZYong Zhang
Yong Zhang
XCXiaogang Chen
Xiaogang Chen
HCHongyan Cui
Hongyan Cui
The hybrid brain-computer interface (hBCI) combining motor imagery (MI) and steady-state visual evoked potential (SSVEP) has been proven to have better performance than a pure MI- or SSVEP-based brain-computer interface (BCI). In most studies on hBCIs, subjects have been required to focus their attention on flickering light-emitting diodes (LEDs) or blocks while imagining body movements. However, these two classical tasks performed concurrently have a poor correlation. Therefore, it is necessary to reduce the task complexity of such a system and improve its user-friendliness. Aiming to achieve this goal, this study proposes a novel hybrid BCI that combines MI and intermodulation SSVEPs. In the proposed system, images of both hands flicker at the same frequency (i.e., 30 Hz) but at different grasp frequencies (i.e., 1 Hz for the left hand, and 1.5 Hz for the right hand), resulting in different intermodulation frequencies for encoding targets. Additionally, movement observation for subjects can help to perform the MI task better. In this study, two types of brain signals are classified independently and then fused by a scoring mechanism based on the probability distribution of relevant parameters. The online verification results showed that the average accuracies of 12 healthy subjects and 11 stroke patients were 92.40 ± 7.45% and 73.07 ± 9.07%, respectively. The average accuracies of 10 healthy subjects in the MI, SSVEP, and hybrid tasks were 84.00 ± 12.81%, 80.75 ± 8.08%, and 89.00 ± 9.94%, respectively. The high recognition accuracy verifies the feasibility and robustness of the proposed system. This study provides a novel and natural paradigm for a hybrid BCI based on MI and SSVEP.

1 August 2019 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
HCHongyan Cui
Hongyan Cui
XXXiaobo Xie
Xiaobo Xie
SXShengpu Xu
Shengpu Xu
LCLeanne Lai-Hang Lai-Hang CHAN
Leanne Lai-Hang Lai-Hang CHAN
YHYong Hu
Yong Hu
Microelectrode arrays play an important role in prosthetic implants for neural signal recording or applying electrical pulses stimulation to target nerve system. Safety and long-term reliability are essential requirements for microelectrode arrays applied in electrical stimulation. In design and fabrication of the microelectrode array, soft materials are generally chosen to be the substrate for the aim of achieving better compliance with the surrounding tissue while maintaining minimal damage. By flexing of the array to the surface, the array is capable of keeping a more stable electrical contact resulting in a significantly improved signal detected. In this study, we design and fabricate a flexible microelectrode array with gold as the electrode material and parylene-C as the substrate. The fabrication process of the array is presented. The in vitro electrochemical characteristics of the microelectrode are investigated by electrochemical impedance spectroscopy and cyclic voltammetry in a three-electrode electrochemical cell containing phosphate-buffered saline. Charge injection capacity measurements are carried out by multichannel systems and the CSC of the microarray is calculated. Electrochemical results showed that impedance decreased with frequency. The average impedance of the Au electrodes at 1 kHz was 36.54 ± 0.88 kΩ. The average phase angle at 1 kHz was − 73.52 ± 1.3°, and the CIC of the microelectrode was 22.3 µC/cm2. The results demonstrated that the microelectrode array performed as expected for neuronal signal recording or stimulation. With parylene-C as the substrate, the microarray has good flexibility. The electrochemical characteristics’ results show that the array has the ability to resist any corrosion on metal–electrolyte interface and has good biocompatibility. This low-cost, flexible parylene-based, gold microelectrode array shows potential for use in implant neurological signal acquisition or neurostimulation applications.

27 November 2018 in Journal of Medical and Biological Engineering
Verified
Journal Article
Open access
PDF file
JLJianing Li
Jianing Li
JPJiangbo Pu
Jiangbo Pu
HCHongyan Cui
Hongyan Cui
XXXiaobo Xie
Xiaobo Xie
SXShengpu Xu
Shengpu Xu
YHYong Hu
Yong Hu
Purpose: P300 component of event related potentials in response to visual and auditory stimulation has been widely used in brain–computer interfaces (BCI). In clinical applications, tactile stimulus based on somatosensory electrical stimulation is an alternative for patients with impaired vision or hearing. This study presents an online P300 BCI based on somatosensory electrical stimulation paradigm. P300 signals were elicited by tactile selective attention of electrical stimuli on four fingers. Methods: Fifteen healthy subjects participated in this study. Participants’ task was to focus their attention on the target finger and count the number. The classification of P300 signals was performed by step-wise linear discriminate analysis. Results: The average classification accuracy of the somatosensory BCI was 79.81 ± 7.91%, with the information transfer rate at 4.9 ± 1.3 bits/min. The BCI performance on different time windows was also evaluated in the present study. Conclusions: Our results demonstrate the feasibility of employing somatosensory electrical stimuli to build a practical online P300 BCI without taxing the visual and auditory channel, providing a wider application prospect in clinical applications and daily life. We anticipate our diagram to be a starting point for more explorations on utilizing electrical somatosensory stimuli in conjunction with portable BCI for neural rehabilitation.

4 October 2023 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
HCHongyan Cui
Hongyan Cui
XCXinyi Chi
Xinyi Chi
LWLei Wang
Lei Wang
XCXiaogang Chen
Xiaogang Chen
Recently, various biosignals have been combined with electroencephalography (EEG) to build hybrid brain-computer interface (BCI) systems to improve system performance. Since steady-state visual evoked potential (SSVEP) and surface electromyography (sEMG) are easy-to-use, non-invasive techniques, and have high signal-to-noise ratio (SNR), hybrid BCI systems combining SSVEP and sEMG have received much attention in the BCI literature. However, most existing studies regarding hybrid BCIs based on SSVEP and sEMG adopt low-frequency visual stimuli to induce SSVEPs. The comfort of these systems needs further improvement to meet the practical application requirements. The present study realized a novel hybrid BCI combining high-frequency SSVEP and sEMG signals for spelling applications. EEG and sEMG were obtained simultaneously from the scalp and skin surface of subjects, respectively. These two types of signals were analyzed independently and then combined to determine the target stimulus. Our online results demonstrated that the developed hybrid BCI yielded a mean accuracy of 88.07 ± 1.43% and ITR of 159.12 ± 4.31 bits/min. These results exhibited the feasibility and effectiveness of fusing high-frequency SSVEP and sEMG towards improving the total BCI system performance.