Ching-Yuan Chang

Prof. Ching-Yuan Chang

Graduate Institute of Environmental Engineering, National Taiwan University, Taipei, 10617, Taiwan

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2007 in Colloids and Surfaces A: Physicochemical and Engineering Aspects
Verified
Journal Article
Closed access
JTJyi-Yeong Tseng
Jyi-Yeong Tseng
Ching-Yuan ChangChing-Yuan Chang
Ching-Yuan Chang
YCYi-Hung Chen
Yi-Hung Chen
CCChiung-Fen Chang
Chiung-Fen Chang
Pen-Chi ChiangPen-Chi Chiang
Pen-Chi Chiang

12 October 2004 in Journal of Chemical Technology & Biotechnology
Verified
Journal Article
Closed access
PDF file
YCYi‐Hung Chen
Yi‐Hung Chen
Ching-Yuan ChangChing-Yuan Chang
Ching-Yuan Chang
WSWei‐Ling Su
Wei‐Ling Su
CCChun‐Yu Chiu
Chun‐Yu Chiu
YYYue‐Hwa Yu
Yue‐Hwa Yu
SCSally Im Chiang
Sally Im Chiang

3 July 2017 in Energies
Verified
Journal Article
Open access
PDF file
MHMichael Huang
Michael Huang
CCChia Chi Chang
Chia Chi Chang
MYMin-Hao Yuan
Min-Hao Yuan
Ching-Yuan ChangChing-Yuan Chang
Ching-Yuan Chang
CWChao-Hsiung Wu
Chao-Hsiung Wu
FLFar-Ching Lin
Far-Ching Lin
The pulp industry in Taiwan discharges tons of wood waste and pulp sludge (i.e., wastewater-derived secondary sludge) per year. The mixture of these two bio-wastes, denoted as wood waste with pulp sludge (WPS), has been commonly converted to organic fertilizers for agriculture application or to soil conditioners. However, due to energy demand, the WPS can be utilized in a beneficial way to mitigate an energy shortage. This study elucidated the performance of applying torrefaction, a bio-waste to energy method, to transform the WPS into solid bio-fuel. Two batches of the tested WPS (i.e., WPS1 and WPS2) were generated from a virgin pulp factory in eastern Taiwan. The WPS1 and WPS2 samples contained a large amount of organics and had high heating values (HHV) on a dry-basis (HHD) of 18.30 and 15.72 MJ/kg, respectively, exhibiting a potential for their use as a solid bio-fuel. However, the wet WPS as received bears high water and volatile matter content and required de-watering, drying, and upgrading. After a 20 min torrefaction time (tT), the HHD of torrefied WPS1 (WPST1) can be enhanced to 27.49 MJ/kg at a torrefaction temperature (TT) of 573 K, while that of torrefied WPS2 (WPST2) increased to 19.74 MJ/kg at a TT of 593 K. The corresponding values of the energy densification ratio of torrefied solid bio-fuels of WPST1 and WPST2 can respectively rise to 1.50 and 1.25 times that of the raw bio-waste. The HHD of WPST1 of 27.49 MJ/kg is within the range of 24–35 MJ/kg for bituminous coal. In addition, the wet-basis HHV of WPST1 with an equilibrium moisture content of 5.91 wt % is 25.87 MJ/kg, which satisfies the Quality D coal specification of the Taiwan Power Co. requiring a value of above 20.92 MJ/kg.

24 June 2019 in Energies
Verified
Journal Article
Open access
PDF file
CCChia Chi Chang
Chia Chi Chang
MDManh Van Do
Manh Van Do
WHWei-Li Hsu
Wei-Li Hsu
BLBo-Liang Liu
Bo-Liang Liu
Ching-Yuan ChangChing-Yuan Chang
Ching-Yuan Chang
TTTrinh Van Tuyen
Trinh Van Tuyen
Combined heat and power production from biogas is now playing an important role in energy and resource utilization as well as pollution control in waste water treatment. This research used biogas from the Bali Sewage Treatment Plant in New Taipei City, Taiwan, as a major source of fuel for the electricity generation. A micro gas turbine electricity generator, Capstone CR-30, which possesses a maximum rated power load (PWL) of 30 kW, was equipped to convert biogas into electricity. The biogas is mainly composed of CH4 (56.1 ± 8.0 vol.%), CO2 (25.5 ± 9.8 vol.%), H2 (0.5 vol.%), and H2S (0.99 ± 0.07 ppmv). During the test operation period of the generator, it was found that the thermal efficiency increases from 19.8% to 23.4% kWhe/kWhth, while the electricity generation efficiency (ηEB) also rises from 0.93 to 1.09 kWhe/m3 biogas as the PWL increases from 10 kW to 30 kW. The results indicated that the generator has a better performance with higher PWL. At PWL = 30 kW, the average adjusted concentrations of CO and NOx (adjusted to 15 vol.% O2) emitted from the generator are 86 ppmv and 17 ppmv, respectively. Both are much lower than the emission standards of stationary sources in Taiwan of 2000 ppmv and 150 ppmv, respectively. Thus, PWL of 30 kW was selected in cooperation with biogas inflow = 0.412 m3/min and air/fuel ratio (i.e., air/biogas ratio) = 76.0 vol./vol. for the long-term regular operation. At the above setting conditions for long-term operation, the generator continuously consumed the biogas and provided stable electricity generation at a rate of 19.64 kWhe/h for a 2-year running period. Moreover, the greenhouse gas can be cut off with a rate of 10.78 kg CO2e/h when using biogas as fuel for electricity generation. Overall, this research proves that the application of a micro gas turbine electricity generator not only has promising performance for using biogas but also gives a significant reduction of greenhouse gas emission, which fits the concepts of the circular economy and environmental protection.

31 May 2012 in Journal of the Taiwan Institute of Chemical Engineers
Verified
Journal Article
Closed access
DMDo-Van Manh
Do-Van Manh
YCYi-Hung Chen
Yi-Hung Chen
CCChia-Chi Chang
Chia-Chi Chang
Ching-Yuan ChangChing-Yuan Chang
Ching-Yuan Chang
CMChau-Van Minh
Chau-Van Minh
HHHoang-Duc Hanh
Hoang-Duc Hanh

3 June 2016 in Sustainability
Verified
Journal Article
Open access
PDF file
YTYen-Chieh Tseng
Yen-Chieh Tseng
Dasheng LeeDasheng Lee
Dasheng Lee
Ching-Fuh LinChing-Fuh Lin
Ching-Fuh Lin
Ching-Yuan ChangChing-Yuan Chang
Ching-Yuan Chang
Small and medium enterprises (SMES) play an important role in Taiwan’s economy. The reduction of energy costs and carbon dioxide (CO2) emissions are critical to preserving the environment. This paper uses the experimental results from 65 sites, gathered over two years since 2012, to determine how the integration of Internet communication, cloud computing technologies and a cloud energy management service (cloud EMS) can reduce energy consumption by cost-effective means. The EMS has three levels: infrastructure as a service (IaaS), platform as a service (PaaS) and software as a service (SaaS). Working jointly with ChungHwa Telecom, Taiwan’s leading telecom service provider, data from detection devices, control devices, air-conditioning and lighting systems are all uploaded to a cloud EMS platform, to give a so called intelligent energy management network application service platform (IEN-ASP). Various energy saving management functions are developed using this platform: (1) air conditioning optimization; (2) lighting system optimization; (3) scheduling control; (4) power billing control and (5) occupancy detection and timing control. Using the international performance measurement and verification protocol (IPMVP), the energy used at the test sites, before and after the use of the IEN-ASP, are compared to calculate the energy saved. The experimental results show that there is an average energy saving of 5724 kWh per year, which represents a saving ratio of 5.84%. This translates to a total reduction in CO2 emissions of 9,926,829 kg per year. Using the data collected, a regression model is used to demonstrate the correlation between the power that is consumed, the energy that is saved and the area of the sites. Another interesting result is that, if the experimental sites are maintained by experienced electricians or other personnel and EMS protocols are followed, the energy saving can be as great as 6.59%.