Radityo Fajar Pamungkas

Mr. Radityo Fajar Pamungkas


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
RPRadityo Fajar Pamungkas
Radityo Fajar Pamungkas
IUIda Bagus Krishna Yoga Utama
Ida Bagus Krishna Yoga Utama
Yeong Min JangYeong Min Jang
Yeong Min Jang
Photovoltaic (PV) systems have immense potential to generate clean energy, and their adoption has grown significantly in recent years. A PV fault is a condition of a PV module that is unable to produce optimal power due to environmental factors, such as shading, hot spots, cracks, and other defects. The occurrence of faults in PV systems can present safety risks, shorten system lifespans, and result in waste. Therefore, this paper discusses the importance of accurately classifying faults in PV systems to maintain optimal operating efficiency, thereby increasing the financial return. Previous studies in this area have largely relied on deep learning models, such as transfer learning, with high computational requirements, which are limited by their inability to handle complex image features and unbalanced datasets. The proposed lightweight coupled UdenseNet model shows significant improvements for PV fault classification compared to previous studies, achieving an accuracy of 99.39%, 96.65%, and 95.72% for 2-class, 11-class, and 12-class output, respectively, while also demonstrating greater efficiency in terms of parameter counts, which is particularly important for real-time analysis of large-scale solar farms. Furthermore, geometric transformation and generative adversarial networks (GAN) image augmentation techniques improved the model’s performance on unbalanced datasets.

3 September 2023 in Sensors
Verified
Journal Article
Open access
PDF file
ONES SANJERICO SITANGGANGONES SANJERICO SITANGGANG
ONES SANJERICO SITANGGANG
VNVan Linh Nguyen
Van Linh Nguyen
HNHuy Nguyen
Huy Nguyen
RPRadityo Fajar Pamungkas
Radityo Fajar Pamungkas
MFMuhammad Miftah Faridh
Muhammad Miftah Faridh
Yeong Min JangYeong Min Jang
Yeong Min Jang
Optical camera communication (OCC) is one of the most promising optical wireless technology communication systems. This technology has a number of benefits compared to radio frequency, including unlimited spectrum, no congestion due to high usage, and low operating costs. OCC operates in order to transmit an optical signal from a light-emitting diode (LED) and receive the signal with a camera. However, identifying, detecting, and extracting data in a complex area with very high mobility is the main challenge in operating the OCC. In this paper, we design and implement a real-time OCC system that can communicate in high mobility conditions, based on You Only Look Once version 8 (YOLOv8). We utilized an LED array that can be identified accurately and has an enhanced data transmission rate due to a greater number of source lights. Our system is validated in a highly mobile environment with camera movement speeds of up to 10 m/s at 2 m, achieving a bit error rate of 10−2. In addition, this system achieves high accuracy of the LED detection algorithm with mAP0.5 and mAP0.5:0.95 values of 0.995 and 0.8604, respectively. The proposed method has been tested in real time and achieves processing speeds up to 1.25 ms.

25 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
IUIda Bagus Krishna Yoga Utama
Ida Bagus Krishna Yoga Utama
RPRadityo Fajar Pamungkas
Radityo Fajar Pamungkas
MFMuhammad Miftah Faridh
Muhammad Miftah Faridh
Yeong Min JangYeong Min Jang
Yeong Min Jang
Due to the accelerated growth of the PV plant industry, multiple PV plants are being constructed in various locations. It is difficult to operate and maintain multiple PV plants in diverse locations. Consequently, a method for monitoring multiple PV plants on a single platform is required to satisfy the current industrial demand for monitoring multiple PV plants on a single platform. This work proposes a method to perform multiple PV plant monitoring using an IoT platform. Next-day power generation prediction and real-time anomaly detection are also proposed to enhance the developed IoT platform. From the results, an IoT platform is realized to monitor multiple PV plants, where the next day’s power generation prediction is made using five types of AI models, and an adaptive threshold isolation forest is utilized to perform sensor anomaly detection in each PV plant. Among five developed AI models for power generation prediction, BiLSTM became the best model with the best MSE, MAPE, MAE, and R2 values of 0.0072, 0.1982, 0.0542, and 0.9664, respectively. Meanwhile, the proposed adaptive threshold isolation forest achieves the best performance when detecting anomalies in the sensor of the PV plant, with the highest precision of 0.9517.


4 January 2024 in Journal of Electrical and Computer Engineering
Verified
Journal Article
Open access
PDF file
ESEko Adhi Setiawan
Eko Adhi Setiawan
MFMuhammad Fathurrahman
Muhammad Fathurrahman
RPRadityo Fajar Pamungkas
Radityo Fajar Pamungkas
SMSamsul Ma’aRif
Samsul Ma’aRif
Maintaining the maximum performance of solar panels poses the foremost challenge for solar photovoltaic power plants in this era. One of the common PV faults which decreases PV power output is a hot spot which is caused by a prolonged local partial shading from objects, such as dust piles or animal waste. To prevent it, an enormous effort for PV inspection is needed especially for large solar power plants. Hence, automatic partial shading detection is critical in preventing PV hot spots to assist maintenance activities which are associated with a drop in energy output. This research developed fast partial shading detection application on PV modules using digital image processing to detect the hot spot and PV modules areas and afterwards calculate the PV systems power loss ratio. The proposed method demonstrated a hot spot detection rate of 94.74% and a module detection rate of 100%. The power loss ratio calculation is compared and validated using IV curve measurement and has 91.26% similarity value which is a feasible application for the real-world system.