Class II malocclusion is a very common condition in orthodontic patients. The reaction force and moment on the teeth induced by a maxillary segmental distalizer (MSD) are essential for understanding tooth movement, tipping, and rotation. This work quantified the three-dimensional (3D) reaction force and moment on canine and molar teeth induced by three different MSDs: the JVBarre (JVB), Carriere Motion 3D (CM3D), and CM3D Clear. A patient-specific mandibular model was reconstructed based on cone-beam computed tomography (CBCT) images. Each of the three MSDs was implanted using finite element analysis (FEA). The reaction force and moment were obtained. The results show that the JVB induced less extrusion force (15% less), tipping (90% less), and rotational moment (70% less) on the canine, compared with the other two CM3Ds. However, the JVB induced a relatively larger extrusion force, tipping, and rotational moment on the molar due to the hook location changing from the end to the middle of the bar. These observations were consistent with the 3D stress distribution of the MSDs. The mechanical understanding from this work may shed light on the optimal design of MSDs.
26 October 2023 in Journal of Engineering and Science in Medical Diagnostics and Therapy
Retinal detachments following blunt ocular trauma are challenging to predict due to the complex and transient biomechanical responses of the globe. This study combines an in vitro weight-drop experiment and finite element analysis (FEA) to evaluate the mechanical pathways leading to traumatic retinal detachment and to predict the spatial likelihood of injury. In the in vitro model, a cylindrical weight was impacted onto freshly enucleated mouse eyes (16 weeks old) supported on a rigid metal plate. Following impact, the eyes were sectioned and stained using hematoxylin and eosin (H&E) for histological assessment. A finite element model of a mouse eye, including the cornea, sclera, lens, zonule, vitreous body, aqueous humor, and retina, was reconstructed from the histological section and used to simulate the whole sequence of compression and rebound following the blunt impact. The simulation demonstrated that the lens retained a high momentum. It generated an alternating compressive (up to −6.57 × 10−3 MPa) and tensile (up to 1.62 × 10−3 MPa) radial stress at the posterior pole and sustained compressive stress at the peripheral region (up to −3.12 × 10−3 MPa) and tensile-compressive stress variation at the equatorial region of the retina. In addition, the regions experiencing tensile stress overlapped with the region exhibiting retinal detachment in the in vitro experiment. These findings highlight the spatiotemporal mapping of biomechanical stress to predict traumatic retinal detachment following blunt impact and provide an understanding of early biomechanical response following ocular trauma.
21 November 2024 in Journal of Engineering and Science in Medical Diagnostics and Therapy