Paiwan Kerdtuad

Dr. Paiwan Kerdtuad

Department of Electrical Engineering, Faculty of Engineering, Rajamangala University of Technology Isan, Khon Kaen Campus, Khon Kaen, Thailand
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2023 in Electronics
Verified
Journal Article
Open access
PDF file
Paiwan KerdtuadPaiwan Kerdtuad
Paiwan Kerdtuad
KCKunjana Chaiamarit
Kunjana Chaiamarit
SKSupat Kittiratsatcha
Supat Kittiratsatcha
This research proposes a roof-mounted auxiliary power supply (APS) system for 600 VDC low-floor light rail vehicles (LRVs). The proposed APS system consists of five parallel-connected dc–ac inverter modules (modules 1–5). Inverter modules 1 and 2 are three-phase dc–ac inverters for the compressor motors of the air conditioning system, and inverter modules 3 and 4 are three-phase dc–ac inverters for the air pump motors of the air supply system. Inverter module 5 is a single-phase dc–ac inverter for the 220 VAC power supply of onboard electric loads. Simulations and experiments were carried out under variable load torques and output frequencies for modules 1–4 and under full and no resistive loads for module 5. The measured total input current and total input power of the proposed APS system under the full-load condition are 114.36 A and 68.84 kW. The total efficiency of the proposed APS system (modules 1–5) is 97.05%. The proposed APS system is suitable for 600 VDC low-floor LRVs. The novelty of this research lies in the use of five parallel-connected inverter modules, as opposed to the three-phase output transformer or isolated dc–dc converter in the early and conventional APS systems. Specifically, the proposed APS system requires neither a three-phase output transformer nor an isolated dc–dc converter.

1 May 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
Paiwan KerdtuadPaiwan Kerdtuad
Paiwan Kerdtuad
KCKunjana Chaiamarit
Kunjana Chaiamarit
SKSupat Kittiratsatcha
Supat Kittiratsatcha
This research proposes a roof-mounted auxiliary power supply (APS) system for 600VDC low-floor light rail vehicle (LRV). The proposed APS system consists of five parallel-connected dc-ac inverter modules (modules 1-5). The inverter modules 1 and 2 are three-phase dc-ac inverters for compressor motors of the cooling system, and the inverter modules 3 and 4 are three-phase dc-ac inverters for air pump motors of the braking system. The inverter module 5 is single-phase dc-ac inverter for 220VAC power supply for onboard electric loads. Simulations and experiments were carried out under variable load torque and output frequency for modules 1 – 4; and under full and no resistive loads for the inverter module 5. The measured total input current and total input power of the proposed APS system under full load condition are 118.76A and 71.25kW. Essentially, the proposed APS system is operationally applicable to the 600VDC low-floor RLV. Besides, the novelty of this research lies in the use of five parallel-connected inverter modules, unlike in the conventional APS systems which require three-phase output transformer or isolated dc-dc converter. Specifically, the proposed APS system requires neither three-phase output transformer nor isolated dc-dc converter.

26 September 2026 in Energies
Verified
Journal Article
Open access
PDF file
Paiwan KerdtuadPaiwan Kerdtuad
Paiwan Kerdtuad
KNKwanjai Nachaiyaphum
Kwanjai Nachaiyaphum
KCKunjana Chaiamarit
Kunjana Chaiamarit
TKThanatchai Kulworawanichpong
Thanatchai Kulworawanichpong
Battery-powered catenary-free light rail vehicles (CF-LRVs) are increasingly adopted as sustainable urban transport solutions, offering advantages such as the elimination of overhead catenary infrastructure, reduced visual intrusion, and enhanced operational flexibility. However, the maximum driving range achievable per charge remains a critical challenge for system design and operation. This range is influenced by factors including route profile, train dynamics, tractive effort, running resistance, traction system efficiency, battery state of charge (SOC), auxiliary power demand, and regenerative braking capability. This study presents an integrated mathematical model for estimating the energy consumption and maximum driving range of a CF-LRV. The model incorporates train dynamics, tractive effort, battery modeling, SOC, regenerative braking, and energy consumption into a unified analytical framework. It is applied to the Khon Kaen Province Red Line Light Rail Transit system in Thailand, with simulations conducted using realistic operating conditions such as station spacing, speed profiles, route gradients, passenger loading, and auxiliary power requirements. Results show that the system achieves a specific energy consumption of 1.90–2.30 kWh/km. Under AW1 loading condition, regenerative braking recovers 31.50% of the traction and auxiliary energy, resulting in a 31.17% increase in driving range compared with the non-regenerative case. With an onboard battery capacity of 240 kWh, the vehicle can travel up to 82.59 km on a single charge. The proposed model provides practical applications in battery sizing, operational planning, and energy management of CF-LRVs, thereby supporting the development of efficient and sustainable battery-powered urban rail systems.

29 December 2023 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
SVSoupagorn Visawaphatradhanadhorn
Soupagorn Visawaphatradhanadhorn
Paiwan KerdtuadPaiwan Kerdtuad
Paiwan Kerdtuad
KCKunjana Chaiamarit
Kunjana Chaiamarit
This paper presents a control approach that utilizes adaptive sliding window Fourier analysis (ASWFA) for single-phase PWM rectifiers. The primary objective is to effectively regulate the output voltage and minimize the ingress of harmonic currents into the utility grid. Through extensive MIL and HIL simulations, the control system demonstrates its efficacy in maintaining voltage regulation, achieving grid synchronization, and managing harmonic currents across various scenarios. The evaluation results affirm the precise control of voltage and regulation of harmonics under different operational conditions. Furthermore, statistical analysis employing box plots provides validation of the control technique's capability to reduce harmonic distortion. The study reveals that only the harmonic groups within the range of 35 ≤ h < 50 exceeded the thresholds prescribed by IEEE Std. 519-2014 for power systems operating at rated voltages between 120 V and 69 kV at the most stringent ISC/IL < 20 requirements. Overall, the proposed control technique presents a viable solution to effectively reduce harmonic distortion.