To evaluate the safety and efficacy of a novel wireless localization technique that uses radiofrequency identification markers for small and deep lung lesions. Preliminary use of the device was retrospectively evaluated in 2 Japanese centers. Under general anesthesia, a marker was placed as close as possible to the tumor via computed tomography-guided bronchoscopy in a hybrid operation theater. Surgeons located the marker without lung palpation using a detection probe the tone of which changed to indicate the marker-probe distance. Efficacy was defined as functional marker placement (bronchoscopy time and marker position) and deep margin distance. Twelve markers were placed for 11 lesions (mean size, 6.8 ± 2.7 mm) located at a mean depth from the pleura of 11.4 ± 8.4 mm (range = 0-26.0 mm). Of 12 markers, 7 markers (58.3%) were placed within 10 mm from the lesion in 25.5 ± 14.4 minutes. For the 11 wedge resections, markers were placed at a mean distance of 6.7 mm (range, 0-13.0 mm) from the lesion and a mean distance of 14.4 mm (range, 3.0-42.0 mm) from the pleura. All markers were recovered without complications, and all tumors were resected with negative margins. For 5 lesions >10 mm deep to the pleura (mean depth, 18.9 ± 5.5 mm; range, 11.0-26.0 mm), the median depth of the surgical margin was 11.6 ± 2.1 mm (range, 9.0-14.0 mm). Radiofrequency identification marking was safe and precisely localized small lung lesions, including their depth.
OBJECTIVES: We developed a novel wireless localization technique after electromagnetic navigation bronchoscopy-guided radiofrequency identification marker placement for fluoroscopically invisible small lung lesions. We conducted an observational study to investigate the feasibility of this technique and retrospectively compared 2 marking approaches with or without cone-beam computed tomography (CBCT). METHODS: Consecutive patients from January 2021 to March 2022 in our institution were enrolled. Markers were placed central to the lesions either in a bronchoscopic suite under intravenous anaesthesia or a hybrid operation theatre with CBCT under general anaesthesia. The efficacy of the 2 marking methods was compared using an inverse probability of treatment weighting adjusted analysis. RESULTS: Totally 80 markers were placed (45 under CBCT and 35 under fluoroscopy) for 74 patients with 80 lesions [mean size: 6.9 mm (interquartile range: 5.1–8.4) at a median depth from the pleura of 14.0 mm (interquartile range: 8.5–19.5)]. The median distance from marker to lesion was 9.1 mm, with a pleural depth of 15.5 mm. The tumour resection rate was 97.5% (78/80) with the median surgical margin of 10.0 mm (interquartile range: 8.0–11.0). Although the bronchoscopy time was longer using CBCT because of the need for 2.8 scans per lesion, the distance from the marker to the lesion was shorter for marking using CBCT than marking using fluoroscopy (adjusted difference: −4.56, 95% confidence interval: −6.51 to −2.61, P < 0.001). CONCLUSIONS: Electromagnetic navigation bronchoscopy-guided radiofrequency identification marking provided a high tumour resection rate with sufficient surgical margins.
Background: Ciliated muconodular papillary tumor (CMPT) is a rare papillary nodule tumor with benign and malignant characteristics that occurs in the peripheral lung. Case presentation: A 70-year-old woman who underwent right hemicolectomy for colorectal cancer (CRC; pT3N0M0, p-stage II) 2 years prior, presented with a sub-centimeter growing cavity shadow on chest computed tomography (CT), which was suspected to be a CRC metastasis. Because positron emission tomography CT suggested there was no other site suspicious of recurrence, thoracoscopic resection with preoperative pleural dye marking was planned to remove the small lesion, which seemed to be hardly palpable on CT. Immediately after pleural dye marking adjacent to the lesion using cone beam CT in the hybrid operating room, thoracoscopic wedge resection was performed and the tumor was finally diagnosed as CMPT, characterized by the papillary growth of mucus-producing cells in the alveoli. Conclusion: We resected the non-palpable small lung lesions following preoperative marking using cone-beam CT in the hybrid operating room. This case highlights a rare cavitary CT image of a CMPT mimicking a metastatic lung tumor from colorectal cancer.